• Title/Summary/Keyword: C.T image analysis

Search Result 101, Processing Time 0.039 seconds

Analysis of Serum Proteom after Intravenous Injection of cultivated wild ginseng pharmacopuncture (산양산삼 증류약침의 혈맥주입 후 나타나는 혈장의 Proteom 분석)

  • Lee, Dong-Hee;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.9 no.2
    • /
    • pp.17-37
    • /
    • 2006
  • Objectives : To observe the changes in the serum proteins after intravenous injection of cultivated wild ginseng pharmacopuncture. Methods : Blood was collected before and after the administration of cultivated wild ginseng pharmacopuncture and only the serum was taken. Then differences in the spots on the scanned image after carrying out 2-Dimensional electrophoresis were located and conducted mass analysis and protein identification. Results : Following results were obtained from the comparative analysis of serum proteins before and after the administration of cultivated wild ginseng pharmacopuncture. 1. 28 spots were identified before and after the administration. 2. In confirming manifestation degree, spots with more than two-times increase were 204, 1302, 2205, 3105, 7104, 8006, spots with more than one-time increase were 1101, 1505, 2013, 2403, 3009, 3010, 4002, 4009, 6704, 8101, and spots with decrease were 205, 801, 803, 3205, 5202, 6105, 6106, 7103, 9001, 9003. 3. After conducting protein identification, proteins 205, 804, 1302, 4009, 6105, 6106 are unidentified yet, and 1l01 is unnamed protein. Protein 204 is identified as complement receptor CR2-C3d, 801 as YAPl protein, 803 as antitrypsin polymer, 1505 as PRO0684, 2013 and 3010 as proapolipoprotein, 2205 as USP48, 2403 as vitamin D binding protein, 3009 as complement component 4A preprotein, 3105 as immunoglobulin lambda chain, 3205 as transthyretin, 4002 as Ras-related protein Ral-A, 4204 as beta actin, 5202 and 7104 as apolipoprotein Ll, 6704 as alpha 2 macroglobulin precursor, 7103 as complement component 3 precursor, 8006 as testis-specific protein Y, 8101 as transferrin, 9001 as (Alpha-Oxy, Beta-(Cl12g)deoxy) T-State Human Hemoglobin, and 9003 as human hemoglobin. 4. Immune protein CR2-C3d(204), which acts against microbes and pathogenic organisms, was increased by more than two-times after the administration of pharmacopuncture. 5. Antitrypsin(803), which is secreted with inflammatory response in the lungs, was reduced after the administration of pharmacopuncture. 6. Proapolipoprotein(2013, 3010) and apolipoprotein(7104), key components of the HDL-cholesterol which plays an important role in preventing arteriosclerosis, were increased after the administration of pharmacopuncture. 7. Vitamin D binding protein(DBP, 2403), protecting the lung at the time of inflammatory response, was increased after the administration of pharmacopuncture. 8. Transthyretin(TTR, 3205), which is the main protein causing familial amyloid polyneuropathy(FAP), was decreased after the administration of pharmacopuncture. 9. Ras-related protein Ral-A(4002) that controls phospholipid metabolism, cytoskeletal formation, and membrane traffic, was increased after the administration of pharmacopuncture. 10. Testis-specific protein Y(8006), which takes part in determination of the gender, was increased by more than two-times after the administration of pharmacopuncture. 11. Transferrin(8101), which balances the iron level in the body, was increased after the administration of pharmacopuncture. Conclusion : Above results support the notion that intravenous injection of cultivated wild ginseng pharmacopuncture induce changes in serum proteins and this research can be a pioneer work in finding biomarkers.

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

Attenuation Estimation of Soft Tissue by the Entropy Method and Statistical Averaging of Speckle Patterns (스펙클 패턴의 통계적 평균과 엔트로피 방식에 의한 초음파 감쇄계수 추정방법)

  • Song, T.K;Park, J.C;Park, S.B
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.253-260
    • /
    • 1989
  • The time domain methods of estimating the attenuation coefficient are generally based on the analysis of statisical properties of the reflected echoes form an attenuating medium. Hence, it is often required to have a large number of data samples in order to obtain a statistically stable estimation result. In the attenuation estimation problem, this means that many different speckle patterns are required in the spatial resolution volume of an attenLlation image. In this paper, by using the fact that the speckle pattern Is sensitive to the point spread function of the ultrasound beam, we suggest a method to generate the statiscally uncorrelated or slightly correlated data samples in a given region by rotating a linear transducer and carrying out lateral scans for all rotating angles. This technique is applied to the entropy method for attenuation estimation proposed recently by the authors where the performance is verified by experiments using a tissue equivalent phantom.

  • PDF

A study on development of suitable healthcare equipment for aged people at their homes - Toward efficiency and reduction of the homehelpers' labor in healthcare

  • Nagao, Tomoko;Mizuno, Hiroyuki;Mitsuhashi, Toshio
    • Proceedings of the Korea Society of Design Studies Conference
    • /
    • 2001.10a
    • /
    • pp.9.1-9
    • /
    • 2001
  • Concerning the development of suitable healthcare equipment for a aged people at their homes in order to reduce the labor and increase the efficiency in the homehelpers' work, we conducted a study on the actual conditions of healthcare in Kyoto city (healthcare in taking a meal and excretion, moving and taking a bath by using a hand-powered lift, moving by a wheelchair, shower carrier healthcare, assistance in body care and housework) by digital video filming, interviews and layout investigations. On the base of those investigations by using methods for analysis of video pictures, we divided the healthcate work into scenes and e exctracted the main problems in terms of health care equipment, information, environment, healthcare skills, mental burden, social s system, family burden, ete. Furthermore the questionnaire survey of home helpers (18 persons - 50% answers) clarified that more than half of them have lumbago pains and the biggest load in the everyday healthcare c comes from moving the patients or getting them into or out of t the equipment for moving. Finally we considered concrete proposals appropriate for each h healthcare scene image, based on evaluation toward efficiency (design guidelines) for suitable healthcare equipment for aged people at their homes: 1) Design toward a proper posture 2) Design toward self-help possibility 3) Design toward patient active participation 4) Design toward rationality of the whole process 5) Design toward place-appropriate healthcare equipment 6) Design toward healing of mind 7) Good level of healthcare skills 8) Economic, systematic rationality

  • PDF

A review on deep learning-based structural health monitoring of civil infrastructures

  • Ye, X.W.;Jin, T.;Yun, C.B.
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.567-585
    • /
    • 2019
  • In the past two decades, structural health monitoring (SHM) systems have been widely installed on various civil infrastructures for the tracking of the state of their structural health and the detection of structural damage or abnormality, through long-term monitoring of environmental conditions as well as structural loadings and responses. In an SHM system, there are plenty of sensors to acquire a huge number of monitoring data, which can factually reflect the in-service condition of the target structure. In order to bridge the gap between SHM and structural maintenance and management (SMM), it is necessary to employ advanced data processing methods to convert the original multi-source heterogeneous field monitoring data into different types of specific physical indicators in order to make effective decisions regarding inspection, maintenance and management. Conventional approaches to data analysis are confronted with challenges from environmental noise, the volume of measurement data, the complexity of computation, etc., and they severely constrain the pervasive application of SHM technology. In recent years, with the rapid progress of computing hardware and image acquisition equipment, the deep learning-based data processing approach offers a new channel for excavating the massive data from an SHM system, towards autonomous, accurate and robust processing of the monitoring data. Many researchers from the SHM community have made efforts to explore the applications of deep learning-based approaches for structural damage detection and structural condition assessment. This paper gives a review on the deep learning-based SHM of civil infrastructures with the main content, including a brief summary of the history of the development of deep learning, the applications of deep learning-based data processing approaches in the SHM of many kinds of civil infrastructures, and the key challenges and future trends of the strategy of deep learning-based SHM.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

Performance Evaluation of Substitution Radiopharmaceutical according to Restriction of the Radiocolloids in Lymphoscintigraphy (Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가)

  • Seo, Young-Deok;Jeong, Jae-Hun;Moon, Jong-Woon;Yun, Sang-Hyeok;Kim, Yeong-Seok;Kang, Se-Hun;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.25-29
    • /
    • 2009
  • Purpose: Several radioactive agents were used for lymphoscintigraphy in breast cancer. But recently, due to the change of local radiopharmaceutical licensing policy and discontinuation of supplies from manufacturer, we could not use many radiocolloids such as $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin. So it is necessary to use the substitution radiopharmaceutical. Therefore, this study aims to evaluate the performance of substitution radiopharmaceutical ($^{99m}Tc$-Phytate) including the existing radiocolloids and to set up of the appropriate protocol in lymphoscintigraphy. Materials and Methods: For each radiocolloids ($^{99m}Tc$-Antimony Trisulfide Colloid (ASC), $^{99m}Tc$-Tin Colloid (TC), $^{99m}Tc$-Human Serum Albumin (HSA), $^{99m}Tc$-Phytate) were performed the particle size by Zeta Sizer (Nano-ZS) and we compared the radiolabeling time, procedure and acquisition time for each of the radiocolloids (total 200 patients). For the last time, we made an analysis of image for each of the radiocolloids with our previous report (SJ Jang et al, Korean Nucl Med Mol imaging Vol.41, No.6, Dec 2007). Results: The particle size of each radiocolloids showed A.S.C (50 nm), T.C (310 nm), H.S.A (10.8 nm), $^{99m}Tc$-Phytate (499 nm). The labeling and acquisition time for each of the radiocolloids showed no substantial difference. But there is difference of the labeling time for the A.S.C. because the ASC procedure need to boiling process. There were no significant differences among those radiocolloids (p>0.005) in the identification rate (IR), false negative rate (FNR), and negative predictive value (NPV). Conclusions: $^{99m}Tc$-labeled radiocolloids showed equivalent results in lymphoscintigraphy. Therefore, in this exam of each radiocolloids could be applied appropriate protocol in lymphoscintigraphy.

  • PDF

Effects of Motion Correction for Dynamic $[^{11}C]Raclopride$ Brain PET Data on the Evaluation of Endogenous Dopamine Release in Striatum (동적 $[^{11}C]Raclopride$ 뇌 PET의 움직임 보정이 선조체 내인성 도파민 유리 정량화에 미치는 영향)

  • Lee, Jae-Sung;Kim, Yu-Kyeong;Cho, Sang-Soo;Choe, Yearn-Seong;Kang, Eun-Joo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.413-420
    • /
    • 2005
  • Purpose: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head mutton correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. Materials and Methods: $[^{11}C]raclopride$ PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Results: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. Conclusion: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.

Photoemission Electron Micro-spectroscopic Study of the Conductive Layer of a CVD Diamond (001)$2{\times}1$ Surface

  • Kono, S.;Saitou, T.;Kawata, H.;Goto, T.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.7-8
    • /
    • 2010
  • The surface conductive layer (SCL) of chemical vapor deposition (CVD) diamonds has attracting much interest. However, neither photoemission electron microscopic (PEEM) nor micro-spectroscopic (PEEMS) information is available so far. Since SCL retains in an ultra-high vacuum (UHV) condition, PEEM or PEEMS study will give an insight of SCL, which is the subject of the present study. The sample was made on a Ib-type HTHP diamond (001) substrate by non-doping CVD growthin a DC-plasma deposition chamber. The SCL properties of the sample in air were; a few tens K/Sq. in sheet resistance, ${\sim}180\;cm^2/vs$ in Hall mobility, ${\sim}2{\times}10^{12}/cm^2$ in carrier concentration. The root-square-mean surface roughness (Rq) of the sample was ~0.2nm as checked by AFM. A $2{\times}1$ LEED pattern and a sheet resistance of several hundreds K/Sq. in UHV were checked in a UHV chamber with an in-situ resist-meter [1]. The sample was then installed in a commercial PEEM/S apparatus (Omicron FOCUS IS-PEEM) which was composed of electro-static-lens optics together with an electron energy-analyzer. The presence of SCL was regularly monitored by measuring resistance between two electrodes (colloidal graphite) pasted on the two ends of sample surface. Figure 1 shows two PEEM images of a same area of the sample; a) is excited with a Hg-lamp and b) with a Xe-lamp. The maximum photon energy of the Hg-lamp is ~4.9 eV which is smaller that the band gap energy ($E_G=5.5\;eV$) of diamond and the maximum photon energy of the Xe-lamp is ~6.2 eV which is larger than $E_G$. The image that appear with the Hg-lamp can be due to photo-excitation to unoccupied states of the hydrogen-terminated negative electron affinity (NEA) diamond surface [2]. Secondary electron energy distribution of the white background of Figs.1a) and b) indeed shows that the whole surface is NEA except a large black dot on the upper center. However, Figs.1a) and 1b) show several features that are qualitatively different from each other. Some of the differences are the followings: the two main dark lines A and B in Fig.1b) are not at all obvious and the white lines B and C in Fig.1b) appear to be dark lines in Fig.1a). A PEEMS analysis of secondary electron energy distribution showed that all of the features A-D have negative electron affinity with marginal differences among them. These differences can be attributed to differences in the details of energy band bending underneath the surface present in SCL [3].

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF