• Title/Summary/Keyword: C.T 영상 분석

Search Result 81, Processing Time 0.027 seconds

Antioxidant Activity and Cytotoxicity on Human Cancer Cells of Anthocyanin Extracted from Black Soybean (검정콩 안토시아닌의 항산화 및 암세포독성)

  • Kim, Yong-Ho;Kim, Dong-Seon;Woo, Sung-Sick;Kim, Hyun-Hee;Lee, Young-Sang;Kim, Hee-Seon;Ko, Kwang-Oh;Lee, Seuk-Ki
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.4
    • /
    • pp.407-412
    • /
    • 2008
  • Anthocyanin pigments in soybean seed coat were D3G (Delphinidin-3-glucoside), C3G (Cyanidin-3- glucoside) and Pt3G (Petunidin-3-glucoside), which have been known potential roles in the prevention and treatment of chronic diseases. Anthocyanin contents in seed coat of blck soybean were significantly different according to soybean variety, C3G content showed the highest value in all materials and its variation was also wide. Antioxidant activity of each pigment was analyzed by DPPH and TEAC methods in which D3G and C3G showed high activity. And this study was carried out to investigate the effects of anthocyanin to human cancer cells. Cytotoxity were analyzed by MTT assay after anthocyanin pigments treated on leukemia (Jurkat T) and adenocarsinoma (MCF-7) cells. It showed decrement of cell numbers as anthocyanin concentration is increasing. ${EC}_50$ range of anthocyanin concentrations were $100{\sim}250\;ug/mL$ and $100{\sim}250\;ug/mL$ in Jurkat T and MCF-7 cell, respectively. D3G showed higher cytotoxicity than other pigments in Jurkat T cell whereas activity of C3G was high in MCF-7 cell. It is believed that supplementation of human diets with soybean anthocyanin markedly reduces human cancer mortality rates.

A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT (간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.217-225
    • /
    • 2019
  • The purpose of this study was to quantitate signal to noise ratio and contrast to noise ratio of the portal vein using CT and 3.0T MRI and to investigate the optimal imaging device. Twenty patients who inspective CT and 3.0T MRI between February 2018 and April 2018 were randomly assigned to receive data from the picture archiving communication system. The SNR and CNR values were evaluated by measuring the mean and standard deviation of the region of interest of the four regions of the portal vein (the main portal vein, the right vein, the left vein, and the middle vein). The results showed that SNR was 9.180.72 in the right context, 9.410.84 in the left context, 9.540.59 in the middle context, 9.550.75 in the order context, and 22.292.03 in the right context and 25.893 in the 3.0T MRI. 19, median context: 24.392.87, and order Mac: 26.642.30 (p<0.05). CNR was 3.790.68 in the CT context, 3.740.65 in the left context, 3.710.39 in the middle context, 3.790.68 in the order context, 9.490.65 in the right context, and 11.0001.90 in the 3.0T MRI, Intermediate context: 12.701.75, order Mac: 10.010.98, 3.0T MRI was higher than CT (p<0.05). In conclusion, SNR and CNR values were higher in the 3.0T MRI than CT in the 4 portal regions. Therefore, 3.0T MRI using non-ionizing radiation was the most superior imaging equipment than CT.

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

A Gait Analysis Using Smart Phone Images of the Knee Joint Angle and Stride Length (스마트폰 영상을 이용한 슬관절 각도 및 활보장에 대한 보행분석)

  • Jang, J.H.;Lim, C.J.;Song, K.H.;Chung, S.T.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.139-144
    • /
    • 2013
  • Various types of disease in the nervous and musculoskeletal system can change gait, and the gait analysis is very important in determining the progression of the disease. Most methods of analyzing gait are subject to high-priced equipment and spatial restrictions. This study used smart phone images and the walking track analysis program to make a comparative analysis with the existing gait analysis on the basis of the stride length measurements and the changes in the knee joint angle for walking. The test necessary to analyze gait was conducted in seven healthy men, and data about the angle of right and left knee joints and stride length were used to analyze gait. The gait analysis in this study obtained the similar results to the existing ones. The use of the methods suggested in this study will enable gait analysis to be made without high-priced equipment and spatial restrictions.

  • PDF

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF

Isolation and Characterization of an Agar-hydrolyzing Marine Bacterium, Pseudoalteromonas sp. H9, from the Coastal Seawater of the West Sea, South Korea (서해안 해수로부터 분리한 한천분해 해양미생물 Pseudoalteromonas sp. H9의 동정 및 특성 연구)

  • Chi, Won-Jae;Youn, Young Sang;Kim, Jong-Hee;Hong, Soon-Kwang
    • Microbiology and Biotechnology Letters
    • /
    • v.43 no.2
    • /
    • pp.134-141
    • /
    • 2015
  • An agarolytic marine bacterium (H9) was isolated from the coastal seawater of the West Sea, South Korea. The isolate, H9, was gram-negative and rod-shaped with a smooth surface and polar flagellum. Cells grew at 20-30℃, between pH 5.0 and 9.0, and in ASW-YP (Artificial Sea Water-Yeast extract, Peptone) media containing 1-5% (w/v) NaCl. The G+C content was 41.56 mol%. The predominant isoprenoid quinone in strain H9 was ubiquinone-8. The major fatty acids (>10%) were C16:1ω7c (34.3%), C16:0 (23.72%), and C18:1ω7c (13.64%). Based on 16S rRNA gene sequencing, and biochemical and chemotaxonomic characterization, the strain was designated as Pseudoalteromonas sp. H9 (=KCTC23887). In liquid culture supplemented with 0.2% agar, the cell density and agarase activity reached a maximum level of OD = 4.32 (48 h) and OD = 3.87 (24 h), respectively. The optimum pH and temperature for the extracellular crude agarases of H9 were 7.0 and 40℃, respectively. Thin-layer chromatography analysis of the agarase hydrolysis products revealed that the crude agarases hydrolyze agarose into neoagarotetraose and neoagarohexaose. Therefore, the new agar-degrading strain, H9, can be applicable for the production of valuable neoagarooligosaccharides and for the complete degradation of agar in bio-industries.

Trends on the Development of Carbon Nanotube-Based Digital X-ray Tube (탄소나노튜브 기반 디지털 엑스선 튜브 기술개발 동향)

  • Song, Y.H.;Kang, J.T.;Kim, J.W.;Choi, Y.C.;Park, S.;Jeong, J.W.
    • Electronics and Telecommunications Trends
    • /
    • v.31 no.2
    • /
    • pp.116-123
    • /
    • 2016
  • 병원의 X선 및 CT 영상, 반도체 소자 내의 결함분석, 공항의 보안검색 등 다양한 분야에 X선이 사용되고 있다. 지금까지는 이러한 X선을 발생시키기 위해 고온으로 가열하여 전자를 방출시키는 열전자원이 사용됐으나, 높은 소비전력과 디지털 구동의 어려움 등의 단점이 존재한다. 이러한 한계를 극복하기 위해 전계방출원 기술, 특히 탄소나노튜브를 이용한 나노전자원의 제조 및 디지털 엑스선 튜브 응용 기술에 관한 연구가 최근 활발히 진행 중이다. 이 글을 통해 디지털 시대에 부합하는 탄소나노튜브 기반 나노전자원 및 이를 이용한 디지털 엑스선 튜브의 개념 및 제조기술을 소개하고, ETRI 및 다른 기관들에서 개발 중인 최신 기술개발 동향을 소개하고자 한다.

  • PDF

Mobile IPTV Technical Trends and Development Strategy (모바일 IPTV 기술 현황 및 연구 추진 방향)

  • Kim, Y.I.;Cho, C.H.;Ryu, W.;Lee, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.25 no.2
    • /
    • pp.68-80
    • /
    • 2010
  • 언제, 어디서나, 고품질의 영상 및 데이터를 제공해주는 모바일 IPTV 서비스는 제 4세대 이동통신 시스템의 주요 서비스로 등장하게 되었고, 이에 따른 각 기술과 서비스들이 연구 개발되고 있다. 본 논문에서는 모바일 TV와 이동통신망을 기반으로 모바일 IPTV 기술을 발전시키는 기술 동향과 더불어 ITU-T, 3GPP, IEEE 802.16 등의 표준화 동향에 대해서 분석한다. 더불어 고품질의 서비스 제공을 위해 필요한 모바일 IPTV의 핵심기술의 도출과 IMT-Advanced WiBro 기반의 모바일 IPTV 요구사항과 시스템 요구사항에 대해서 기술한다.