• Title/Summary/Keyword: C-kit

검색결과 575건 처리시간 0.023초

Evaluation on Microbiological Contamination Level of Raw Beef from Retail Markets in Seoul, Korea (서울지역 식육판매점의 우육에 대한 미생물학적 오염도 평가)

  • Ko, Eun-Kyung;Heo, Eun Jeong;Kim, Young Jo;Park, Hyun Jung;Wi, Seong-Hwan;Moon, Jin San
    • Food Science of Animal Resources
    • /
    • 제33권3호
    • /
    • pp.403-410
    • /
    • 2013
  • This study was performed to evaluate the microbiological contamination level of raw beef from retail markets in Seoul, Korea. The sampling and laboratory test were performed according to the procedure of "Standard for processing and ingredients specification of livestock product" and "Korean food code". Enterotoxin of Staphylococcus aureus isolates were detected using VIDAS$^{(R)}$ and PCR-based methods. Listeria monocytogenes serotyping and genotyping were carried out using Listeria antisera and L. monocytogenes Fingerprinting kit, respectively. A total of 48 samples were collected from 16 retail markets (butcher's shop: 5, department store: 6, supermarket: 5) in 2011. The level of total bacteria counts in the butcher's shop, department store and supermarket were $4.4{\times}10^3$ CFU/g, $3.9{\times}10^5$ CFU/g and $1.0{\times}10^4$ CFU/g, respectively. The concentrations of Escherichia coli of these three retail markets were $6.4{\times}10$ CFU/g, 7.6 CFU/g and $2.0{\times}10$ CFU/g, respectively. Salmonella species was not detected on all samples. However, S. aureus was isolated in the 3 samples (6.25%) from each type of three retail markets. L. monocytogenes was isolated in the 4 samples (8.3%) from department stores. The level of contamination of these foodborne bacteria was less than 100 CFU/g. The enterotoxin-encoding genes of S. aureus isolates were sea, seh, sei and sep gene. The gene similarity of L. monocytogenes isolated from two retail markets by Rep-PCR showed 57.8-98.1% and 68.1-98.1%, respectively. These results suggest that the HACCP guideline for environmental control in slaughterhouse and retail markets should be provided to prevent cross contamination and manage foodborne pathogens such as L. monocytogenes and S. aureus.

Effects of Plant Water Extract Mixture Ixeris Sonchifolia Hance, Oenanthevjavanica, Fagopyrum Esculentum Moench, Hizikia Fusiforme, Zingiber Officinale Roscoe on Mouse Immune Cell Activation Ex vivo (5가지 (고들빼기, 돌미나리, 메밀, 톳, 생강)혼합식품 물 추출물의 마우스 면역세포 활성화 효과)

  • Ryu, Hye-Sook;Kim, Jung-Hee;Kim, Hyun-Sook
    • Journal of Nutrition and Health
    • /
    • 제41권2호
    • /
    • pp.141-146
    • /
    • 2008
  • Ixeris sonchifolia Hance (Godulbaegi), Oenanthe javanica (Dolminari), Fagopyrum esculentum Moench (Buckwheat>, Hizikia fusiforme (Seaweed Fusiforme) and Zingiber ojficinale Roscoe (Ginger) have been used respectively as one of folk remedies as well as food materials. However, reportedly few studies on their immunomodulating effects have been made, although it has been known from other preceding studies that the ex vivo supplementation of each Ish, OJ, Fem, Hf, Zor water extracts tends to enhance the proliferation of splenocyte in comparison to the control group. This study on the combined immunomodulative effect of water extract mixture of these five food materials (Ish + Oj + Fem +Hf+Zor) lasted covering seven or eight weeks. The old mice (balb/c) was fed ad libitum on chow diet, and the water extract of plant mixture was orally administrated every other day for four weeks at two different concentrations (50 and 500 mg/kg B.W) . After preparing the single cell suspension, the proliferation of splenocyte was determined by MTT (3-[4,5-dimethylthiazol-2-y]-2,5-diphenyl terazolium bromide) assay. The production of cytokine ($IL-{\beta}$, IL-6, and $TNF-{\alpha}$) which was secreted by macrophages stimulated with LPS or not was detected by ELISA assay using the cytokine kit. After the 48 hours of incubation with the mitogen (ConA or LPS) stimulation, the proliferation of the mice splenocyt in the experimental group statisticaly increased at both of two different concentrations in comparison to the control group. The cytokines production was more significantly enhanced at the lower supplementation (50 mg/kg B.W.) group than at the higher concentration (500 mg/kg B.W.). The result of this study may suggest that the supplementation of water extract of plant mixture can regulate and enhance the immune function by increasing the splenocyte proliferation and regulating the cytokine production capacity by the activated macrophages in mice.

Optimization of a Medium for the Production of Cellulase by Bacillus subtilis NC1 Using Response Surface Methodology (반응 표면 분석법을 사용한 Bacillus subtilis NC1 유래 cellulase 생산 배지 최적화)

  • Yang, Hee-Jong;Park, Chang-Su;Yang, Ho-Yeon;Jeong, Su-Ji;Jeong, Seong-Yeop;Jeong, Do-Youn;Kang, Dae-Ook;Moon, Ja-Young;Choi, Nack-Shick
    • Journal of Life Science
    • /
    • 제25권6호
    • /
    • pp.680-685
    • /
    • 2015
  • Previously, cellulase and xylanase producing microorganism, Bacillus subtilis NC1, was isolated from soil. Based on the 16S rRNA gene sequence and API 50 CHL test the strain was identified as Bacillus subtilis, and named as B. subtilis NC1. We cloned and sequenced the genes for cellulase and xylanase. Plus, the deduced amino acid sequences from the genes of cellulase and xylanase were determined and were also identified as glycosyl hydrolases family (GH) 5 and 30, respectively. In this study to optimize the medium parameters for cellulase production by B. subtilis NC1 the RSM (response surface methodology) based on CCD (central composite design) model was performed. Three factors, tryptone, yeast extract, and NaCl, for N or C source were investigated. The cellulase activity was measured with a carboxylmethyl cellulose (CMC) plate and the 3,5-dinitrosalicylic acid (DNS) methods. The coefficient of determination (R2) for the model was 0.960, and the probability value (p=0.0001) of the regression model was highly significant. Based on the RSM, the optimum conditions for cellulase production by B. subtilis NC1 were predicted to be tryptone of 2.5%, yeast extract of 0.5%, and NaCl of 1.0%. Through the model verification, cellulase activity of Bacillus subtilis NC1 increased from 0.5 to 0.62 U/ml (24%) compared to the original medium.

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제14권2호
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제20권2호
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF