• Title/Summary/Keyword: C-Scan 영상

Search Result 116, Processing Time 0.023 seconds

Automatic Defect Detection and Classification Using PCA and QDA in Aircraft Composite Materials (주성분 분석과 이차 판별 분석 기법을 이용한 항공기 복합재료에서의 자동 결함 검출 및 분류)

  • Kim, Young-Bum;Shin, Duk-Ha;Hwang, Seung-Jun;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.4
    • /
    • pp.304-311
    • /
    • 2014
  • In this paper, we propose a ultra sound inspection technique for automatic defect detection and classification in aircraft composite materials. Using local maximum values of ultra sound wave, we choose peak values for defect detection. Distance data among peak values are used to construct histogram and to determine surface and back-wall echo from the floor of composite materials. C-scan image is then composed through this method. A threshold value is determined by average and variance of the peak values, and defects are detected by the values. PCA(principal component analysis) and QDA(quadratic discriminant analysis) are carried out to classify the types of defects. In PCA, 512 dimensional data are converted into 30 PCs(Principal Components), which is 99% of total variances. Computational cost and misclassification rate are reduced by limiting the number of PCs. A decision boundary equation is obtained by QDA, and defects are classified by the equation. Experimental result shows that our proposed method is able to detect and classify the defects automatically.

Comparison between FDG Uptake and Clinicopathologic and Immunohistochemical Parameters in Pre-operative PET/CT Scan of Primary Gastric Carcinoma (원발성 위암 환자의 치료 전 PET/CT 스캔에서 FDG 섭취 정도와 임상병리학적 및 면역조직화학적 지표들과의 비교)

  • Han, Eun-Ji;Choi, Woo-Hee;Chung, Yong-An;Kim, Ki-Jun;Maeng, Lee-So;Sohn, Kyung-Myung;Jung, Hyun-Suk;Sohn, Hyung-Sun;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.26-34
    • /
    • 2009
  • Purpose: The purpose of this study was to find out what clinicopathologic or immunohistochemical parameter that may affect FDG uptake of primary tumor in PET/CT scan of the gastric carcinoma patient. Materials and Methods: Eighty-nine patients with stomach cancer who underwent pre-operative FDG PET/CT scans were included. In cases with perceptible FDG uptake in primary tumor, the maximum standardized uptake value (SUVmax) was calculated. The clinicopathologic results such as depth of invasion (T stage), tumor size, lymph node metastasis, tumor differentiation and Lauren's classification and immunohistochemical markers such as Ki-67 index, expression of p53, EGFR, Cathepsin D, c-erb-B2 and COX-2 were reviewed. Results: Nineteen out of 89 gastric carcinomas showed imperceptible FDG uptake on PET/CT images. In cases with perceptible FDG uptake in primary tumor, SUVmax was significantly higher in T2, T3 and T4 tumors than T1 tumors ($5.8{\pm}3.1$ vs. $3.7{\pm}2.1$, p=0.002). SUVmax of large tumors (above or equal to 3 cm) was also significantly higher than SUVmax of small ones (less than 3 cm) ($5.7{\pm}3.2$ vs. $3.7{\pm}2.0$, p=0.002). The intestinal types of gastric carcinomas according to Lauren showed higher FDG uptake compared to the non-intestinal types ($5.4{\pm}2.8$ vs. $3.7{\pm}1.3$, p=0.003). SUVmax between p53 positive group and negative group was significantly different ($6.0{\pm}2.8$ vs. $4.4{\pm}3.0$, p=0.035). No significant difference was found in presence of LN metastasis, tumor differentiation, Ki-67 index, and expression of EGFR, Cathepsin D, c-erb-B2 and COX-2. Conclusion: T stage of gastric carcinoma influenced the detectability of gastric cancer on FDG PET PET/CT scan. When gastric carcinoma was perceptible on PET/CT scan, T stage, size of primary tumor, Lauren's classification and p53 expression were related to degree of FDG uptake in primary tumor.

Evaluation of Patients with Rheumatoid Arthritis by Tc-99m MIBI Imaging (류마티스 관절염환자에서 Tc-99m MIBI 영상의 유용성 평가)

  • Cho, Ihn-Ho;Chun, Kyung-Ah;Hong, Young-Hoon;Lee, Choong-Ki;Ha, Jeung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.506-510
    • /
    • 2004
  • Purpose: We investigated whether Tc-99m MIBI imaging is useful to predict the response of drug treatment in patients with rheumatoid arthritis. Materials and Methods: 24 patients (15 women and 9 men, age $49{\pm}12$ year) rheumatoid arthritis and treated with disease modifying antirheumatic drugs (DMARDs) were included in this study. Erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) were measured, and Tc-99m MIBI scan was obtained before drug treatment. Quantitative analysis of uptake in diseased joints was performed and expressed as joint-to background ratio (J/B) and percent retention (%R) of Tc-99m MIBI. Clinical symptoms were evaluated and graded from 0 (no) to 3 (severe) regarding to presence of tenderness and swelling. Results: J/B of the diseased joints were significantly correlated with ESR and CRP (p<0.05). A highly significant correlation was found between the improvement of clinical symptoms and %R of Tc-99m MIBI (p<0.05). Conclusion: The results demonstrate that Tc-99m MIBI scan may be used to predict the therapeutic response in patients with rheumatoid arthritis.

Development of Image Processing S/W for UT-NDE of Steam Generator of Nuclear Power Plant (핵발전소 증기발생기의 초음파 비파괴 평가를 위한 영상처리 소프트웨어 개발)

  • Lee, Young-Seock
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.217-222
    • /
    • 2006
  • This paper describes a development of ultrasonic examination analysis software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. This software provides the information of shape, depth, size and position of flaws. To do such, we obtain raw data from specimens and/or real pipeline of power plants and, modify the obtained ultrasonic 1-dimensional data according to prepared software design schedule. The developed analysis software is applied to specimens containing various flaws with known dimensions. The results of applications showed that the developed software provided accurate and enhanced images of flaws on various specimens.

  • PDF

Character Segmentation in a Grayscale Image using the Standard Deviation (그레이스케일 영상에서 표준 편차를 이용한 문자 분할)

  • Jung, Min Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.27-31
    • /
    • 2012
  • This paper proposes a new method of character segmentation in a grayscale image using the standard deviation. Firstly, the proposed method scans vertically the region of interest in an image in order to calculate a standard deviation for each scan line. Characters' standard deviations are much bigger than the background's. Therefore, it is possible to segment characters vertically using the differentiation of those two types of standard deviations. Secondly, the method scans each vertically segmented image horizontally at this time, and then segments each image similarly. The proposed method is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiments were conducted by using credit card images. The results show that the proposed algorithm is quite successful for most credit cards. However, the method fails in some credit cards with strong background patterns.

Development of Image Processing Software for Ultrasonic NDE (초음파 비파괴 검사를 위한 영상처리 소프트웨어 개발)

  • Park, Jin-Hong;Nam, Myung-Woo;Lee, Young-Seock
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.459-460
    • /
    • 2007
  • In this paper, we describe a development of ultrasonic nondestructive evaluation software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. And it can analyze the size and the location of internal cracks using 2D image. To do such, we obtain raw data from specimens of real pipeline of power plants, and get the crack points using LPF and differential method from obtained ultrasonic 1-dimensional data. The results of applications showed that the developed software provided accurate images of cracks on various specimens.

  • PDF

Efficient Hardware Design of SPIHT Algorithm for Image Compression (영상압축을 위한 SPIHT 알고리즘의 효율적인 하드웨어 설계)

  • Yu Mong;Song Moonbin;Chung Yunmo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.11a
    • /
    • pp.187-190
    • /
    • 2004
  • This paper proposes an efficient hardware implementation of SPIHT(Set Partitoning In Hierarchical Tree) algorithm for image compression with the discrete wavelet transform. An efficient technique to scan the coefficients which are located in partitioned spatial orientation trees by DWT is considered in terms of counter fields for sorting pass and refinement pass. The proposed image compression method using SPIHT has been modeled in VHDL and has been implemented by use of both TMS320C6000 as a DSP and Virtex2 as a Xilinx FPGA.

  • PDF

Urinary Tract Infection in Febrile Infants with Pyuria (발열과 농뇨가 있는 영아에서 요로감염에 관한 연구)

  • Lee, Sue Young;Cho, Sung Hee;Kim, Sun Mi;Jeong, Dae Chul;Chung, Seung Yeon;Lee, Kyung Yil;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.1
    • /
    • pp.90-100
    • /
    • 2004
  • Objective : Urinary tract infection(UTI) is a frequent serious bacterial infection in young infants. The clinical presentation may be non-specific and variable, depends on factors such as the age and the level of infection. Children with renal involvement may be at risk of permanent renal damage. Experimental studies have shown that renal lesions caused by acute febrile UTI may be prevented or diminished by early diagnosis and treatment. Therefore, it is important to find a method that can permit early diagnosis and identification of patients who are at risk for progressive renal damage. We designed this study to identify related factors in culture positive UTI infants, and also to identify related factors in culture negative UTI infants, who are febrile with pyuria, by using renal imaging and functional studies including renal sonography, DMSA scan and VCUG. Methods : Retrospectively analyzed the medical records of 136 febrile infants with pyuria over 2 years(from January 2001 to February 2003). Urine culture was done in all cases, and regardless of urine culture findings, renal imaging study was done if symptomatic UTI suspected. Results : Total 57 organisms were isolated in 53 patients. E. coli was the most common organism(86%), followed by E. faecalis, M. morganii, Proteus species, P. aeruginosa, S. aureus and E. fergusonii. Most of the isolates had high sensitivity on cephalosporins or amikacin and had low sensitivities on aminopenicillins. Abnormal acute phase DMSA scan or VCUG findings were seen in both urine culture positive and negative group without statistical differences(P>0.05). In febrile infants with pyuria, fever over 48 hours, older age and high CRP related to abnormal acute phase DMSA scan findings regardless urine culture results. Conclusion : 1st or 3rd generation cephalosporins with amikacin could be the first choice of treatment for UTI. Febrile infants with positive urine culture dose mean urinary tract infection but not acute pyelonephritis which directly relates to cortical damage which could be confirmed by acute phase DMSA scan. Even cases with negative urine culture findings, acute pyelonephritis should be concerned in febrile infants with pyuria who are older than 3 months of age, has fever over 48 hours or high CRP level. And in such cases, acute phase DMSA scan and VCUG should be evaluated for early treatment and long term prognosis.

  • PDF

Smoking-Induced Dopamine Release Studied with $[^{11}C]Raclopride$ PET ($[^{11}C]Raclopride$ PET을 이용한 흡연에 의한 도파민 유리 영상 연구)

  • Kim, Yu-Kyeong;Cho, Sang-Soo;Lee, Do-Hoon;Ryu, Hye-Jung;Lee, Eun-Ju;Ryu, Chang-Hung;Jeong, In-Soon;Hong, Soo-Kyung;Lee, Jae-Sung;Seo, Hong-Gwan;Jeong, Jae-Min;Lee, Won-Woo;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.421-429
    • /
    • 2005
  • Purpose: It has been postulated that dopamine release in the striatum underlies the reinforcing properties of nicotine. Substantial evidence in the animal studies demonstrates that nicotine interacts with dopaminergic neuron and regulates the activation of the dopaminergic system. The aim of this study was to visualize the dopamine release by smoking in human brain using PET scan with $[^{11}C]raclopride$. Materials and Methods: Five male non-smokers or ex-smokers with an abstinence period longer than 1 year (mean age of $24.4{\pm}1.7$ years) were enrolled in this study $[^{11}C]raclopride$, a dopamine D2 receptor radioligand, was administrated with bolus-plus-constant infusion. Dynamic PET was performed during 120 minutes ($3{\times}20s,\;2{\times}60s,\;2{\times}120s,\;1{\times}180s\;and\;22{\times}300s$). following the 50 minute-scanning, subjects smoked a cigarette containing 1 mg of nicotine while in the scanner. Blood samples for the measurement of plasma nicotine level were collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, and 90 minute after smoking. Regions for striatal structures were drawn on the coronal summed PET images guided with co-registered MRI. Binding potential, calculated as (striatal-cerebellar)/cerebellar activity, was measured under equilibrium condition at baseline and smoking session. Results: The mean decrease in binding potential of $[^{11}C]raclopride$ between the baseline and smoking in caudate head, anterior putamen and ventral striatum was 4.7%, 4.0% and 7.8%, respectively. This indicated the striatal dopamine release by smoking. Of these, the reduction in binding potential in the ventral striatum was significantly correlated with the cumulated plasma level of the nicotine (Spearman's rho=0.9, p=0.04). Conclusion: These data demonstrate that in vivo imaging with $[^{11}C]raclopride$ PET could measure nicotine-induced dopamine release in the human brain, which has a significant positive correlation with the amount or nicotine administered bt smoking.

Image Evaluation of Resolution Parameter and Reconstitution Filter in 256 Multi Detector Computed Tomography by Using Head Phantom (256 다중 검출기 전산화단층촬영에서 두개부 전용 팬톰을 이용한 분해능 파라메터와 재구성 필터의 영상 평가)

  • Gu, Bon-Seung;Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.814-821
    • /
    • 2011
  • The purpose of this study was to evaluate of resolution parameter and reconstitution filter in the 256 multi detector computed tomography(MDCT) by using the head phantom. We used 256 MDCT, and head phantom of philips system. We evaluated to image quality by using Extended Brilliance Workspace. The protocol were axial scan method with 120 kVp, 0.5 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of field of view(FOV), $512{\times}512$ of matrix size, 1.0 of pitch, $128{\times}0.625$ mm of collimations. The resolution parameter was applied for 'Standard', 'High' and 'Ultrahigh'. The reconstitution filters were changed to seven type of 'A', 'B', 'C', 'D', 'UA', 'UB', 'UC'. The assesment factors of image quality were the uniformity, the noise, the linearity and 50% and 10% of the modulation transfer function(MTF). Finally The good image quality in 'High' resolution parameter showed at the uniformity, the linearity and 50% and 10% of MTF. The 'UA', 'UB' reconstitution filter showed at the good image quality of the uniformity and the noise and 'C' reconstitution filter showed at the same result of the linearity and 50% and 10% of MTF.