• Title/Summary/Keyword: C 대역

Search Result 746, Processing Time 0.026 seconds

Amorphous Lithium Lanthanum Titanate Solid Electrolyte Grown on LiCoO2 Cathode by Pulsed Laser Deposition for All-Solid-State Lithium Thin Film Microbattery (전고상 리튬 박막 전지 구현을 위해 펄스 레이저 증착법으로 LiCoO2 정극위에 성장시킨 비정질 (Li, La)TiO3고체 전해질의 특성)

  • 안준구;윤순길
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.8
    • /
    • pp.593-598
    • /
    • 2004
  • To make the all-solid-state lithium thin film battery having less than 1 fm in thickness, LiCoO$_2$ thin films were deposited on Pt/TiO$_2$/SiO$_2$/Si substrate as a function of Li/Co mole ratio and the deposition temperature by Pulsed Laser Deposition (PLD). Especially, LiCoO$_2$ thin films deposited at 50$0^{\circ}C$ with target of Li/Co=1.2 mole ratio show an initial discharge capacity of 53 $\mu$Ah/cm$^2$-$\mu$m and capacity retention of 67.6%. The microstructural and electrochemical properies of (Li, La)TiO3 thin films grown on LiCoO$_2$Pt/TiO$_2$/SiO$_2$/Si structures by Pulsed Laser Deposition (PLD) were investigated at various deposition temperatures. The thin films grown at 10$0^{\circ}C$ show an initial discharge capacity of approximately 51 $\mu$Ah/cm$^2$-$\mu$m and moreover show excellent discharge capacity retention of 90% after 100 cycles. An amorphous (Li, La)TiO$_3$ solid electrolyte is possible for application to solid electrolyte for all-solid-state lithium thin film battery below 1 $\mu$m.

Implementation of a Library Function of Scanning RSSI and Indoor Positioning Modules (RSSI 판독 라이브러리 함수 및 옥내 측위 모듈 구현)

  • Yim, Jae-Geol;Jeong, Seung-Hwan;Shim, Kyu-Bark
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.11
    • /
    • pp.1483-1495
    • /
    • 2007
  • Thanks to IEEE 802.11 technique, accessing Internet through a wireless LAN(Local Area Network) is possible in the most of the places including university campuses, shopping malls, offices, hospitals, stations, and so on. Most of the APs(access points) for wireless LAN are supporting 2.4 GHz band 802.11b and 802.11g protocols. This paper is introducing a C# library function which can be used to read RSSIs(Received Signal Strength Indicator) from APs. An LBS(Location Based Service) estimates the current location of the user and provides useful user's location-based services such as navigation, points of interest, and so on. Therefore, indoor, LBS is very desirable. However, an indoor LBS cannot be realized unless indoor position ing is possible. For indoor positioning, techniques of using infrared, ultrasound, signal strength of UDP packet have been proposed. One of the disadvantages of these techniques is that they require special equipments dedicated for positioning. On the other hand, wireless LAN-based indoor positioning does not require any special equipments and more economical. A wireless LAN-based positioning cannot be realized without reading RSSIs from APs. Therefore, our C# library function will be widely used in the field of indoor positioning. In addition to providing a C# library function of reading RSSI, this paper introduces implementation of indoor positioning modules making use of the library function. The methods used in the implementation are K-NN(K Nearest Neighbors), Bayesian and trilateration. K-NN and Bayesian are kind of fingerprinting method. A fingerprint method consists of off-line phase and realtime phase. The process time of realtime phase must be fast. This paper proposes a decision tree method in order to improve the process time of realtime phase. Experimental results of comparing performances of these methods are also discussed.

  • PDF

The Influence of PbO Content on the Crystallisation Characteristics and Dielectric Properties of Glass Frit for LTCC (LTCC용 Glass Frit의 결정화 특성 및 유전 특성에 대한 PbO 함량의 영향)

  • Park, Jeong-Hyun;Kim, Yong-Nam;Song, Kyu-Ho;Yoo, Jae-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.5
    • /
    • pp.438-445
    • /
    • 2002
  • In this study, the glass frit of $PbO-TiO-2-SiO_2-BaO-ZnO-Al_2O-3-CaO-B_2O_3-Bi_2O_3-MgO$ system was manufactured. The glass was melted at $1,400{\circ}C$, quenched and attrition-milled. The glass frit powder was pressed and fired for 2h at the range of $750~1,000{\circ}C$. The crystallization of glass frit began at about $750{\circ}$ and at low temperature, the main crystal phases were hexagonal celsian($BaAl_2Si_2O_8$) and alumina. As the firing temperature increased, the crystal phases of monoclinic celsian, zinc aluminate, zinc silicate, calcium titanium silicate and titania appeared. And the increase of firing temperature led to transformation of hexagonal celsian to monoclinic. The only glass frit containing 15wt% PbO had the crystal phase of solid solution of $PbTiO_3-CaTiO_3$. At the frequency of 1 MHz, the dielectric constant of glass frit crystallized was in the range of 11~16 and the dielectric loss less than 0.020. But the glass frit containing 15wt% PbO had the dielectric constant of 17~26 and loss of 0.010~0.015 because of crystal phase of solid solution of $PbTiO_3-CaTiO_3$.

Environmental Test Results of a Flight Model of a Compact Imaging Spectrometer for a Microsatellite STSAT-3 (과학기술위성3호 소형영상분광기 발사모델 환경시험 결과)

  • Lee, Sang-Jun;Kim, Jung-Hyun;Lee, Jun-Ho;Lee, Chi-Won;Jang, Tae-Sung;Kang, Kyung-In
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.184-190
    • /
    • 2011
  • A compact imaging spectrometer (COMIS) was developed for a microsatellite STSAT-3. The satellite is now rescheduled to be launched into a low sun-synchronous Earth orbit (~700 km) by the end of 2012. Its main operational goal is the imaging of the Earth's surface and atmosphere with ground sampling distance of 27 m and 2 - 15 nm spectral resolution over visible and near infrared spectrum (0.4 - 1.05 ${\mu}m$). A flight model of COMIS was developed following an engineering model that had successfully demonstrated hyperspectral imaging capability and structural rigidity. In this paper we report the environmental test results of the flight model. The mechanical stiffness of the model was confirmed by a small shift of the natural frequency i.e., < 1% over 10 gRMS random vibration test. Electrical functions of the model were also tested without showing any anomalies during and after vacuum thermal cycling test with < $10^{-5}$ torr and $-30^{\circ}C\;-\;35^{\circ}C$. The imaging capability of the model, represented by a modulation transfer function (MTF) value at the Nyquist frequency, was also kept unvaried after all those environmental tests.

Microwave Dielectric Properties and Far Infrared Spectrum of $(Pb_{1-x}Ca_x)(Fe_{0.5}Ta_{0.5})O_3$ Ceramics ($(Pb_{1-x}Ca_x)(Fe_{0.5}Ta_{0.5})O_3$ 세라믹스의 마이크로파 유전특성 및 Far Infrared Spectrum)

  • 박흥수;윤기현;김응수
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.3
    • /
    • pp.256-262
    • /
    • 2000
  • The dielectric properties of complex perovskite ($Pb_{1-x}Ca_{x}$)($Fe_{0.5}Ta_{0.5}$)$O_{3}$ with >($0.5{\le}x{\ge}0.65$ were investigated at microwave frequencies. Dilectric constant decreased with increasing Ca content, and was directly proportional to the cube of average ionic ra야 of A-site. For the specimen of x=0.6 sintered at $1250^{\circ}C$ for 3 h in air, dielectric constant (k) of 63, QF of 11000 GHz, and the temperature coefficient of resonant frequency(TCF) of -14ppm/$^{\circ}C$ were obtained. As Ca content increased, TCF of the specimen negatively increased due to the reduction of the tolerance factor(t). Changes in intrinsic loss with varying Ca content was investigated by the infrared reflectivity spectra ranging 50 to 4000 $cm^{-1}$, which were calculated by the Kramers-Kronig analysis and classical oscillator model. The relative tendency of microwave dielectric properties of the ($Pb_{1-x}Ca_{x}$)($Fe_{0.5}Ta_{0.5}$)$O_{3}$ specimens calculated from the reflectivity data were in good agreement with the results by the post resonant method.

  • PDF

Design and Performance Evaluation of 8PSK-TCM System Using Turbo Equalizer for Satellite Communication (위성통신을 위한 터보 등화기를 사용하는 8PSK-TCM 시스템 설계와 성능 평가)

  • An, Changyoung;Ryu, Sang-Burm;Lee, Sang-Gyu;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.11
    • /
    • pp.837-842
    • /
    • 2017
  • In this paper, as a basic study for combination of turbo equalizer and 4D-8PSK-TCM(4 Dimensional 8 Phase Shift Keying Trellis Coded Modulation) system, which is recommended for X-band band satellite communication in CCSDS, a system combining 8PSK-TCM system and turbo equalizer has designed and performance evaluation of the system has performed. BER performance of 8PSK and 8PSK-TCM systems has evaluated and analyzed in AWGN, Proakis B and Proakis C channels in detail. As results of simulation, BER performance of 8PSK-TCM system is better than 8PSK system in AWGN environment. Furthermore, it can be confirmed that the system combining the 8PSK-TCM system with the turbo equalizer can further improve the BER performance through iterative equalization in the ISI channel environment. The 8PSK-TCM system combined with the turbo equalizer requires SNR of 5.9 dB for BER performance of $10^{-3}$ with 5 iterative equalization in Proakis B and SNR of 9.1 dB for BER of $10^{-2}$ with 5 iterative equalization in Proakis C.

Effects of Green Tea Catechin on Microsomal Phospholipase A2 Activity and Arachidonic Acid Cascade in Rat Lung Exposed to Microwave (마이크로웨이브를 조사한 흰쥐 폐조직의 Phospholipae A2 활성과 Arachidonic Acid Cascade계에 미치는 녹차 Catechin의 영향)

  • Kim, Mi-Ji
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.7
    • /
    • pp.936-942
    • /
    • 2012
  • In the present study, the effects of green tea catechin on microsomal phospholipase $A_2$ ($PLA_2$) activity and the arachidonic acid (AA) cascade in the lungs of microwave exposed rats were investigated. One Sprague-Dawley male rats weighting $100{\pm}10$ g was randomly assigned to the normal group and three were assigned to the microwave exposed groups. The microwave exposed groups were subdivided into three groups according to the levels of dietary catechin supplementation: catechin free diet (MW) group, 0.25% catechin (MW-0.25C) group and 0.5% catechin (MW-0.5C) group. Rats were sacrificed on the 6th day after microwave irradiation (2.45 GHz, 15 min). The lung microsomal $PLA_2$ activity in the MW and MW-0.25C groups was 30% and 15% greater than that of the normal group, respectively, whereas no significant difference between the normal group and MW-0.5C group was observed. The percentage of phosphatidylethanolamine (PE) hydrolyzed in the lung microsome in the MW, MW-0.25C and MW-0.5C group increased by 47%, 18% and 20%, respectively, due to microwave irradiation. The formation of thromboxane $A_2$ ($TXA_2$) in the lung microsome was 50% greater in the MW group than in the normal group. However, the levels of $TXA_2$ in the MW-0.25C and MW-0.5C group were normal. The formation of prostacyclin ($PGI_2$) in the lung microsome was 31% lower in the MW group than in the normal group, while the levels of $PGI_2$ in the MW-0.25C and MW-0.5C group were similar to the normal group. The lung microsomal thiobarbituric acid reactive substances (TBARS) concentration, which can be used as an index of lipid peroxide was 34% greater in the MW group, when compared with the normal group. However, there was no difference between the MW-0.25C, MW-0.5C and normal groups. In conclusion, lung function appeared to be improved by green tea catechin supplementation due to its antithrombus action, which in turn controls the AA cascade system.

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Minimizing non-optimal paths in multi-hop ad hoc network adopted IEEE 802.11 PSM (IEEE 802.11 PSM을 적용한 다중 홉애드 혹 네트워크에서 우회경로의 최소화)

  • Whang, Do-Hyeon;Lee, Jang-Su;Kim, Sung-Chun
    • The KIPS Transactions:PartC
    • /
    • v.14C no.7
    • /
    • pp.583-588
    • /
    • 2007
  • It is easy to implement a temporary network with a mobile ad-hoc network in which mobile nodes have without using a infrastructure network. They depend on their limited power. Recently, it is a hot issue to save the energy in a mobile ad-hoc network because a mobile nodes have a limited energy. Research of IEEE 802.11 PSM was proposed in a single hop ad-hoc assumption. If IEEE 802.11 PSM is applied to multi hop ad-hoc network, non-optimal paths will be generated by the mobile nodes which didn't receive a message of routing request. Non-optimal paths increase not only a network latency but also energy consumption of mobile nodes. Reconfiguring algorithm of non-optimal paths caused by the mobile nodes which didn't receive a message of routing request is proposed in this paper. A mobile node can overhear the data in his range. A wireless medium is shared by all mobile nodes using the same bandwidth. All mobile nodes lookout the non-optimal paths with these properties of a medium, if non-optimal path is generated, optimal reconfiguring will be accomplished by modifying routing table of itself or sending a request message of routing update to nearby nodes. By reconfiguring the non-optimal paths to optimized ones, network latency and energy consumption was decreased. It is confirmed to ignore the overhead caused by a algorithm presented in this paper through the result of the simulation.

A $64\times64$ IRFPA CMOS Readout IC for Uncooled Thermal Imaging (비냉각 열상장비용 $64\times64$ IRFPA CMOS Readout IC)

  • 우회구;신경욱;송성해;박재우;윤동한;이상돈;윤태준;강대석;한석룡
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.5
    • /
    • pp.27-37
    • /
    • 1999
  • A CMOS ReadOut Integrated Circuit (ROlC) for InfraRed Focal Plane Array (IRFPA) detector is presented, which is a key component in uncooled thermal imaging systems. The ROIC reads out signals from $64\times64$ Barium Strontium Titanate (BST) infrared detector array, then outputs pixel signals sequentially after amplifying and noise filtering. Various design requirements and constraints have been considered including impedance matching, low noise, low power dissipation and small detector pitch. For impedance matching between detector and pre~amplifier, a new circuit based on MOS diode structure is devised, which can be easily implemented using standard CMOS process. Also, tunable low pass filter with single~pole is used to suppress high frequency noise. In additions, a clamping circuit is adopted to enhance the signal~to-noise ratio of the readout output signals. The $64\times64$ IRFPA ROIC is designed using $0.65-\mu\textrm{m}$ 2P3M (double poly, tripple metal) N~Well CMOS process. The core part of the chip contains 62,000 devices including transistors, capacitors and resistors on an area of about $6.3-mm\times6.7-mm$.

  • PDF