• 제목/요약/키워드: C/R

검색결과 18,343건 처리시간 0.037초

혼합냉매 (R290/R32) 적용 소프트 아이스크림 제조기 (drop-in 시험) (Soft ice-cream maker operating with mixed refrigerant R290/R32)

  • 박태균;한성필;이응렬;김내현;박형채
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.410-413
    • /
    • 2005
  • Drop-in tests were conducted using R290/R32 (31:69) mixture in an ice-cream maker for possible replacement of R-502 and R-404A. Optimum refrigerant charge and TEV opening were obtained through a series of experiments. At the standard outdoor condition ($35^{\circ}C$ DT, $24^{\circ}C$ WT), the time required for initial ice-cream making was 6'22", which was approximately the same as that of R-404A. The electric energy consumed was 660 kJ, which was about 10% higher than that of R-404A. The compressor outlet temperature ($8^{\circ}C$) and pressure (2.52 MPa) were higher than those ($60^{\circ}C$ and 1.48 MPa) of R-404A. The reason could be the usage of the same R-404A compressor although the specific volume of R290/R32 is much larger.

  • PDF

R407C 및 R410A의 수평원관내 응축열전달 (Condensation heat transfer of R407C and R410A in a horizontal smooth tube)

  • 서정현;김민수
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.633-641
    • /
    • 1999
  • Experiments were carried out to investigate the condensation heat transfer characteristics for R22 and its alternatives, R407C (R32/125/134a, 23/25/52wt%) and R410A (R32/125, 50/50wt%). A concentric tube heat exchanger was made to conduct condensation heat transfer tests. Mass flux and saturation temperature of refrigerants at the test section inlet were varied to get the corresponding heat transfer coefficients. Serial and parallel input of secondary fluid (water) were applied to the test subsections. Compared with existing correlations of condensation heat transfer, experimental heat transfer coefficients obtained in this study were generally higher than the predicted values, and mean absolute deviations from several correlations were shown. Wall subcooling was introduced to get a new correlation for condensation heat transfer coefficients by modifying Shah's equation. The RMS deviation of the measured heat transfer coefficients from the new correlation in this study for R22 is 9.9% and that for R407C and R410A are 10.2% and 14.6%, respectively.

  • PDF

그래핀 옥사이드(Graphen Oxide, GO)와 환원 그래핀의 (Reduced graphe oxide, R-GO)의 물리화학적 특성 연구 (Research on Physicochemical Properties of Graphene Oxide (GO) and Reduced Graphene Oxide (R-GO) )

  • 김무선;이호용;최성웅
    • Composites Research
    • /
    • 제36권3호
    • /
    • pp.167-172
    • /
    • 2023
  • 복합재료 제작 기술은 저비용, 유연성 그리고 용이한 가공성 등을 그대로 유지하면서 필러(filler)의 특성을 부여하는 방법을 지향하고 있으며 다양한 기능성 복합재료 개발로 이루어지고 있다. 기능성 복합재 구현과 관련하여 그래핀(Graphene)을 필러로 사용하는 복합재료의 고성능화 연구가 활발히 진행되고 있다. 본 연구에서는 기능성 물성치 향상을 위해 많이 사용되는 그래핀을 이용하여 물리 화학적 물성치를 고찰하였다. 대표적 filler인 graphane nanoplatelet(GNP)을 사용하여 그래핀 옥사이드(graphene oxide, GO)를 제조하였고 그래핀 옥사이드(GO) 를 환원시켜 reduced graphene oxide(R-GO)를 형성하였다. 각기 제조된 GO와 R-GO의 물성치를 분석하였고 이를 GNP 분석결과와 비교하여 제조된 방법의 신뢰성을 검토하였다. Raman 분광법에 의한 분석 결과 R-GO의 경우 GO에 비해 D-peak와 G-peak의 강도의 감소를 확인할 수 있었고 ID/IG의 비를 통해 0.08의 증가 값을 볼 수 있었다. FTIR을 이용한 GNP, GO 및 R-GO의 작용기 분석 결과 C-C, C=C의 반복되는 연결 구조를 가진 GNP와는 다르게 GO 및 R-GO의 경우 명확한 peak를 통해 C-O 결합, C=C 결합, C=O 결합 및 O-H 결합을 확인할 수 있었다. X-ray 회절 분석 결과 GNP는 (002) 평면 특성의 25.86°에서 넓은 회절의 peak를 보인 반면 GO와 R-GO는 (001), (100) 평면에 해당하는 peak를 볼 수 있었고 GO의 층간거리는 GNP에 비해 약 2.6배 증가한 것을 확인할 수 있었다.

The Phylotype of Thermus from the Rehai Geothermal Area, Tengchong, China

  • Guo, Chunlei;Wang, Tao;Zhu, Wei;Zhang, Donghua;Cui, Xiaolong;Xu, Lihua;Peng, Qian
    • Journal of Microbiology
    • /
    • 제41권2호
    • /
    • pp.152-156
    • /
    • 2003
  • Through enrichment on two nutrient agars, 57 Thermus isolates were recovered from 15 hot spring samples taken from the Rehai geothermal area, Tengchong, China. Unique growth characteristics were observed when the strains were transferred from YIM14 medium to Thermus medium. Phylogenetic analysis showed that the 16S rDNA sequences of the isolates and clones from the Rehai geothermal area farmed a monophyletic group on the phylogenetic tree. A secondary structure comparison showed that their 16S rRNAs have unique secondary structure characteristics.

벤처기업가의 정치적 기술과 사회적 네트워크의 하위요인 간의 구조적 관계모형 (A Structural relationship model in consideration of subordinate factors between venture entrepreneurs' political skill and social network)

  • 정대용;김춘광
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.718-727
    • /
    • 2011
  • 본 연구는 중소 벤처기업들의 태생적 약점을 극복하게 해 주는 것으로 알려진 사회적 네트워크와 그 원천인 정치적 기술 간의 관계구조를 실증 고찰한 연구이다. 211명의 벤처기업가 응답을 근거로 한 구조방정식 모형 분석 결과, 첫째 네트워킹 능력은 사회적 네트워크의 약한 유대(${\beta}$=.527, C.R.=3.626), 강한 유대(${\beta}$=.594, C.R.=3.969), 네트워크 중심성(${\beta}$=.418, C.R.=4.884)에 모두 유의하고 강한 정(+)의 영향을 미치는 것으로 나타났으며, 둘째, 사회적 통찰력 역시 약한 유대(${\beta}$=.192, C.R.=1.701), 강한 유대 (${\beta}$=.269, C.R.=2.509) 그리고 네트워크 중심성(${\beta}$=.228, p=2.283)에 유의한 정(+)의 영향을 미치는 것으로 나타났다. 셋째 대인관계 영향력은 강한 유대(${\beta}$=-.264, C.R.=-1.862)와 네트워크 중심성(${\beta}$=-.394, C.R.=-2.914)에만 유의한 영향을 미치는 것으로 나타났는데 부호의 방향이 (-)인 것으로 나타났다. 마지막으로 외형적 진실성은 사회적 네트워크의 하부요인들에 유의한 영향을 미치지 않는 것으로 나타났다. 연구결과는 사회적 네트워크와 사회적 역량의 관계를 실증 분석했다는 점 외에 중소 벤처기업 기업가들에게 그들의 태생적 한계 극복을 위한 실제적인 정보를 제공했다는 점에서 의의가 있다. 또한 사회적 역량의 구체적 실체인 정치적 기술 개념을 제안하고 실증분석 함으로써, 기업가적 역량 구축에 관심을 둔 향후 연구들의 이론적 토대를 제공했다는 점에 큰 의의가 있다.

R-22 대체용 혼합냉매의 Drop-In 열역학적 성능 계산 (Drop-In Evaluation of Thermodynamic Performance of R-22 Alternative Refrigerant Mixtures)

  • 주종문;김창년;박영무
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.423-436
    • /
    • 1996
  • Thermodynamic performance of eight zeotropic R-22 alternative refrigerant mixtures selected by AREP(R-22 Alternative Refrigerants Evaluation Program) and R-32/R-125/R-134a(23%/25%/52%), namely R-407C were evaluated by the "drop-in" simulation method. An existing air conditioner was selected and its design data were used for the simulation. "ARI Test A" air conditions were applied. The degree of vapor superheat at the compressor inlet fixed at $5^{\circ}C$ for all the mixtures. The results of the simulation were compared with those of R-22. COPs of all mixtures except for R-32/R-227ea(35%/65%) and R-32/R-125/R-134a(10%/70%/20%), were higher than that of R-22 by 2%~8%, while the capacities were all lower than that of R-22 by 13%~27%. COP of R-32/R-134a(40%/60%) was 2.4% higher but the capacity was 15% lower than those of R-22. In the case of R-32/R-134a(30%/70%), COP and capacity were 5.5% higher and 15% lower than those of R-22, respectively. Among the ternary mixtures, R-407C and R-32/R-125/R-134a(30%/10%/60%) showed the best performance. COP of R-407C was 2.4% higher than those of R-22 but the capacity was 15% lower.

  • PDF

Flexural behavior of reinforced lightweight concrete beams under reversed cyclic loading

  • Chien, Li-Kai;Kuo, Yi-Hao;Huang, Chung-Ho;Chen, How-Ji;Cheng, Ping-Hu
    • Structural Engineering and Mechanics
    • /
    • 제52권3호
    • /
    • pp.559-572
    • /
    • 2014
  • This paper presents the results of an experimental investigation on the flexural behavior of doubly reinforced lightweight concrete (R.L.C.) beams tested under cyclic loading. A total of 20 beam specimens were tested. Test results are presented in terms of ductility index, the degradation of strength and stiffness, and energy dissipation. The flexural properties of R.L.C. beam were compared to those of normal concrete (R.C.) beams. Test results show that R.L.C. beam with low and medium concrete strength (20, 40MPa) performed displacement ductility similar to the R.C. beam. The ductility can be improved by enhancing the concrete strength or decreasing the tension reinforcement ratio. Using lightweight aggregate in concrete is advantageous to the dynamic stiffness of R.L.C. beam. Enhancement of concrete strength and increase of reinforcement ratio will lead to increase of the stiffness degradation of beam. The energy dissipation of R.L.C beam, similar to R.C. beam, increase with the increase of tension reinforcement ratio. The energy dissipation of unit load cycle for smaller tension reinforcement ratio is relatively less than that of beam with higher reinforcement ratio.

버들치 Rhynchocypris oxycephalus와 버들개 R. steindachneri에 대한 리도카인의 마취 효과 (Effect of Lidocaine as an Anaesthetic on Rhynchocypris oxycephalus and R. steindachneri)

  • 박인석;김정혜;정장방;임재현
    • 한국양식학회지
    • /
    • 제11권1호
    • /
    • pp.59-66
    • /
    • 1998
  • 버들치 Rhynchocypris oxycephalus와 버들개 R. steindachneri를 대상으로 마취 수온 10도C, 15도C 및 20도C에서 염산리도카인(염산리도카인/NaHCO하(3))의 마취 효과를 조사하였다. 마취 시간과 회복 시간을 고려시 효과적인 염산리도카인 농도는 버들치에서 300ppm ($20^{\circ}C.$), 400ppm ($15^{\circ}C.$) 및 600ppm ($10^{\circ}C.$) 이었고 버들개에서 400ppm ($20^{\circ}C.$), 500ppm ($15^{\circ}C.$) 및 600ppm ($10^{\circ}C.$) 이었다. 마취시간과 회복시간에 있어 버들치 속 2종은 염산리도카인 농도 및 마취 수온 의존적이었다. 각 염산리도카인 농도에서 개체 크기가 증가할수록 마취 시간이 길어졌으며, 개체 크기가 큰 군은 마취 농도가 증가할수록 회복 시간 역시 길어졌다. 본 연구 결과 염산리도카인은 버들치 속어류 마취에 효과적인 것으로 판명되었다.

  • PDF

DEAD-box RNA Helicase 유전자가 결핍된 Bacillus subtilis의 저온 충격 반응성과 저온 안정성 전사물 (Cold Shock Response and Low Temperature Stable Transcript of DEAD-box RNA Helicase in Bacillus subtilis)

  • 오은하;이상수
    • 미생물학회지
    • /
    • 제47권4호
    • /
    • pp.289-294
    • /
    • 2011
  • Bacillus subtilis에 존재하는 DEAD-box RNA helicase 유전자의 결손이 저온 충격에 민감성을 보이는지를 조사하였다. 저온 충격에 민감한지를 알아 보기 위하여 대수기에($O.D_{600}$=0.5-0.6) 있는 세포를 $15^{\circ}C$도 낮추어 저온충격을 가하여 생장하는 정도를 조사하였다. DEAD-box RNA helicase 유전자 ydbR, yfmL, yqfR, deaD의 결손 균주들이 저온충격을 가하였을 때 ydbR 결손 균주의 생장이 야생형 균주에 비해 5배 정도 현저히 감소하였으나, 다른 DEAD-box RNA helicase 유전자의 (yfmL, yqfR, deaD) 결손은 야생형 균주와 비슷한 생장을 보였다. 저온에서의 유전자 발현을 알아보기 위하여 Northern blot으로 mRNA 양을 알아본 결과 $37^{\circ}C$에 비해 $15^{\circ}C$에서 ydbR과 yqfR의 mRNA전사물 증가를 확인할 수 있었고, 반면에 yfmL과 deaD의 전사 증가는 관찰되지 않았다. $37^{\circ}C$에서 $15^{\circ}C$로 저온 충격을 가하면 ydbR mRNA 양의 뚜렷한 증가를 확인하였고, 전사 억제제인 rifampicin를 처리하여 ydbR mRNA의 양을 조사하였을 때 $15^{\circ}C$ 조건에서는 mRNA 양이 거의 유지하는 반면에 $37^{\circ}C$ 조건에서는 급격한 mRNA의 감소가 일어나 전사과정에서 유도되기 보다는 전사 후 전사물의 안정에 기인하는 것으로 보인다. 이와 관련하여 ydbR 유전자의 5' UTR (untranaslated region) 부근에서 csp (cold shock protein) 유전자에서 관찰되는 cold box element를 확인하였고, ydbR이 저온 충격 조건에서 발현되는 과정이 csp와 유사하게 전사물의 안정성에 기인함을 알 수 있었다.

R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구 (An experimental study on the performance of a window system air-conditioner using R407C and R410B)

  • 김만회;신정섭;김권진
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF