• Title/Summary/Keyword: Bypass valve

Search Result 253, Processing Time 0.023 seconds

Traumatic Tricuspid Regurgitation as a Cause of Failure to Wean from Mechanical Ventilation

  • Jeon, Yang Bin;Park, Chul Hyun;Ma, Dae Sung
    • Journal of Trauma and Injury
    • /
    • v.33 no.4
    • /
    • pp.264-268
    • /
    • 2020
  • A 55-year-old man underwent emergent sternotomy due to cardiac tamponade occurring just after an accidental fall from a 10-m height. Tricuspid valve regurgitation was found on echocardiography while he was on mechanical ventilation after the operation. The patient was weaned successfully from mechanical ventilation after tricuspid valve repair under cardiopulmonary bypass. Traumatic tricuspid valve regurgitation is a rare blunt chest injury and its symptoms occur late. Tricuspid regurgitation should be considered as a reason for failure to wean from mechanical ventilation after blunt cardiac trauma.

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 Cell Saver 를 이용한 자가수혈의 효과)

  • 정경영
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.260-267
    • /
    • 1990
  • During a eight month period[from December, 1988 to July, 1989], a series of 35 adults undergoing redo-valve replacement or coronary artery bypass grafting was selected to an autotransfusion group[n=10] or a control group[n=25]. The Cell Saver System[Haemonetics Corp., Graintree, Mass] was employed for autotransfusion. With this system, all blood shed in the operative field before and after cardiopulmonary bypass and remained in cardiotomy reservoir after cardiopulmonary bypass was aspirated by means of a locally heparinized collecting system. After the salvaged blood was centrifuged, the resulting red cell concentrate subsequently reinfused. The patients receiving autologous blood required significantly less banked homologous blood than their controls[3213k1020 ml and 506051931 ml, respectively: p=0.001] There were no clinical infections in the autotransfusion group, although 40% of the cultures of processed blood were positive. And there was no apparent intergroup difference of the clinical and the hematologic and hemostatic laboratory findings. We conclude that autotransfusion using cell saver is effective for saving the homologous blood transfusion in cardiac surgery.

  • PDF

A Study on Injection Characteristics of Piezo Injector with Bypass by Various Piezo Stack and Applied Voltage (바이패스 방식 피에조 인젝터의 피에조 적층 및 인가전압에 따른 연료분사 특성 연구)

  • Cho, Insu;Kim, Wootaek;Lee, Jinwook
    • Journal of ILASS-Korea
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • In the common rail fuel injection system, which is the core of diesel high efficiency and NOX reduction, injection strategies such as high pressure injection of fuel, accurate injection rate control, and multistage injection are important to increase fuel atomization. In this study, the bypass type piezo injector for the electronic control based common rail injection system applied to diesel fuel vehicle was studied. In particular, the injection rate and internal fuel flow characteristics of the high-pressure injector according to the piezo stacking number and applied voltage were analyzed by theoretical numerical method. When the applied voltage changes, it is determined that additional fuel flow through the bypass compensates for the reduced valve driving force due to the change in the driving voltage.

Posterior Left Ventricular Wall Rupture After Mitral Valve Replacement (승모판 치환술후 발생한 좌심실 후벽 파열)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1254-1260
    • /
    • 1992
  • Rupture of the posterior left ventricular wall following mitral valve replacement is a rare but fatal complication. Over a 10 year period from August 25 1980 to November 27 1990, we have experienced 6 such patients among 884 cases of mitral valve replacement with 4 deaths and 2 survivors. One patient had a type I rupture and another a type II rapture with the remaining four patients having suffered type III ruptures. All of the ruptures were dis covered intraoperatively enabling prompt reinstitution of the cardiopulmonary bypass and subsequent cardioplegic arrest prior to repair. Overzealous removal of calcified valve leaflets seemed to be responsible for the single type I rupture, and untethering of the so called ventricular loop appeared to be the main mechanism responsible for the type III ruptures. The single type II rupture that had occurred seemed to have been caused by inadvertent laceration of the papillary muscle with resultant rupture of the posterior LV wall at the base of the papillary muscle. Among the type III ruptures, 2 patients required intraaortic balloon pump[IABP] support only for mechanical assistance and 1 patient required both the IABP and the Biomedicus LV assist device for successfull weaning following repair of the LV rupture Another patient with a type II rupture also required the circulatory assistance of both the IABP and the bio-medicus LV assist device for weaning from the bypass. Attention to meticulous technical considerations such as avoiding over aggressive removal of heavily calcified valvular tissue, preservation of as much mural leaflet tissue and chordal stuctures as possible seemed helpful in preventing this catastrophic complication from occurring. Fusion and fibrous stricture of the chordal structures appeared particularly conducive to the type II ruptures as a result of the increased susceptibility to papillary injury during operation.

  • PDF

Performance Test of Pressure and Flow Rate in a Hot-Water Heating System with 3-Way Valves for Flow Bypass (바이패스용 3-Way 밸브를 장착한 온수 난방시스템의 압력 및 유량 특성 평가)

  • Hur, Jurn;Lee, Suk-Jong;Sung, Jae-Yong;Lee, Myeong-Ho;Yoon, Jai-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.269-274
    • /
    • 2007
  • A 3-way valve has been applied to a distributor in a hot-water heating system and the performance of the system was evaluated in view of the variations of pressure drop and flow rate. The 3-way valve has been designed to bypass overplus hot-water when a control valve is closed. Note that the flow goes through heating pipeline in normal operation. In the present study, the measured pressure drops in each part of the flow paths show that the contribution to the total pressure drop is in the order of the supply header with control valves, piping system of each room and return header of the distributor, even though the amount of it is different according to the flow paths. As a result of performance test by sequential closing of the control valves, the variations of pressure drop and flow rate in the distributor with 3-way valves is much lower than those with previous 2-way valves, which prevent noises induced by pressure fluctuations.

Clinical Experiences of Open Heart Surgery [50 Cases] (개심술 치험 50례)

  • 임진수
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.692-699
    • /
    • 1985
  • Fifty cases of Open Heart Surgery due to congenital and acquired heart disease were done using the cardiopulmonary bypass in the Department of Thoracic and Cardiovascular surgery, Chosun University Hospital from November, 1980 to June, 1985. 1. The age of the congenital heart disease was from 7 to 29 years, the mean age was 14.5 years. In the acquired heart disease, the age was from 14 to 48 years, and the mean age was 22.3 years. The ratio of male to female was about 1.8:1. 2. The number of congenital cyanotic heart disease were 7 patients, congenital acyanotic heart disease were 17 patients and acquired valvular heart disease were 26 patients. All of the acquired heart disease was one or more valve disease. 3. Preoperative symptoms of the congenital heart disease were exertional dyspnea [cyanotic 100%, acyanotic 70.6%] and palpitation [cyanotic 28.6%, acyanotic 76.1%], and the acquired heart diseases were exertional dyspnea [92.3%], palpitation [34.1 %], and chest discomfort [30.8%]. 4. The method of the myocardial protection during the cardiopulmonary bypass were mild or moderate hypothermia, intermittent coronary perfusion of the cardioplegic solution, topical myocardial hypothermia with 4oC Hartmann`s solution. 5. In the cases of the valve replacement, postoperative oral anticoagulant therapy was started at oral intake of food using the warfarin and persantin, and the prothrombin time was maintained 30-50% of control value during 3-6 months for tissue valve replacement and permanently for metal valve replacement. 6. The postoperative complications were appeared in 24 cases and the complications were wound infection, occipital alopecia, hemorrhage etc. 7. The mortality after open heart surgery was 8 percents and the cause of death was low cardiac output syndrome, right heart failure, DIC, and Left ventricle rupture.

  • PDF

Efficacy of Mitral Valve Surgery in Moderate Ischemic Mitral Regurgitation (MR) (중등도의 허혈성 승모판막 폐쇄부전증 환자에서 승모판막 수술의 유용성)

  • Jung Sung Ho;Lee Jae Won;Choi Jun Young
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.357-365
    • /
    • 2005
  • Background: Patients with mitral regurgitation (MR) in the setting of coronary artery disease have a dismal long-term prognosis whether treated medically or surgically. Moreover, the optimal management of moderate ischemic MR at the time of coronary artery bypass grafting (CABG) remains the subjects of controversy. Thus, the present retrospective study was undertaken to determine whether mitral valve surgery for moderate ischemic MR at the time of CABG would be preferable to CABG alone in terms of clinical outcome. Material and Method: Between January 1997 and December 2003, 34 patients with moderate (Gr 3/4) ischemic MR underwent CABG alone (Group I, n=23) or CABG plus mitral valve surgery (Group II, n=11). Operative mortality, long-term survival and echocardiographic parameters were used to evaluate the efficacy of mitral valve surgery in patients with moderate ischemic MR. The mean follow-up durations of each group were $69.3\pm4.3$ months and $53.1\pm4.9$ months respectively. Result: There was no hospital mortality in both groups. There was one case of late mortality in Group I. The mean number of bypass graft was similar ($3.8\pm1.2\;vs\;3.7\pm1.3$ respectively). Cardiopulmonary bypass time was longer in group II (p=0.014). In group II, all of the patients received mitral annuloplasty using ring. On immediate postoperative echo-cardiogram, mitral regurgitation was reduced more in group II (p=0.002). Echocardiogram performed at last follow-up state showed no difference except the grade of MR between the two groups. Actuarial survival of both groups at 5 years was similar ($95.5\%\;vs\;100\%$, p=0.48). Conclusion: This study shows that in selected patients with moderate ischemic MR, CABG without mitral valve surgery might be sufficient. However, patients with low EF and NYHA functional class pre-operatively had tendency of significant residual MR, so mitral valve surgery should be necessary in these patients, and moreover, MR severity and left ventricle volume decreased more in mitral valve surgery group. Therefore, more large-scale studies are necessary to determine these effects on the ventricular function and long-term survival.

Double Valve Replacement: report of 5 cases (연합판막질환의 판치환수술)

  • 노중기
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.355-360
    • /
    • 1979
  • Mitral and aortic valve replacement with tricuspid annuloplasty was undertaken in 5 patients out of 38 valvular surgery between the period from Jan. 1977 to May 1979 in the Dept. of Thoracic and Cardiovascular Surgery in Korea University Hospital. All were male patients with age ranging from 18 to 42 years, and preoperative evaluation revealed one case in Class IV, and four cases in Class III according to the classification of NYHA. Preoperative diagnosis was confirmed by routine cardiac study including retrograde aorto- and left ventriculography, and there were two cases with MSi+ASi+Ti, two cases with MSi+Ai+Ti, and one case with Mi+Ai+Ti. Double valve replacement was performed under the hypothermic cardiopulmonary bypass with total pump time of 247 min. in average ranging from 206 min. to 268 min. During aortic valve replacement, left coronary perfusion was done in the first two cases, and cardiac arrest with cardioplegic solution proposed by Bretschneider was applied in the remained three cases. Starr-Edwards, Bjork-Shiley prosthetic valves and Carpentier-Edwards tissue valve were replaced in the aortic area, and Carpentier-Edwards and Angell-Shiley tissue valves were replaced in the mitral area with each individual combination [three prosthetic and two tissue valves in the aortic, and five tissue valves in the mitral area respectively]. Postoperative recovery was uneventful in all cases except one case with hemopericardium, which was managed with pericardiectomy on the postoperative 10th day in good result. Follow-up after double valve replacement of the all five cases for the period from 6 months to 33 months revealed satisfactory adaptation in social activity and occupation with cardiac function of Class I according to the classification of NYHA In all five cases.

  • PDF

Syphilitic aortic aneurysm -A case report- (매독성 대동맥류의 수술치험 -1예 보고-)

  • 김범식
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.475-478
    • /
    • 1986
  • Syphilitic aortic aneurysm is a rare lesion today. We experienced a case of huge syphilitic ascending aortic aneurysm with aortic insufficiency. Surgical correction was done by replacement of ascending aorta with woven Dacron graft and aortic valve replacement under cardiopulmonary bypass. There is no abnormality in postoperative aortography. The postoperative course was uneventful.

  • PDF

Clinical experience of open heart surgery -70 cases- (개심술 70예의 임상경험)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.644-662
    • /
    • 1986
  • Seventy cases of open heart surgery were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje College, from Oct. 1985 to Oct. 1986. And the results were summarized as follows. 1. Among the 70 cases, there were 48 cases of congenital heart anomalies and 22 cases of acquired rheumatic valvular heart diseases. Age range of the congenital patients was 7 months to 31 years with the mean age of 10 years, and the acquired patients was 18 to 62 years with the mean age of 40 years. 2. The heart-lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 5 of membrane type and 65 of bubble type. For all cases GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 48 congenital anomalies, there were 12 cases of ASD group, 29 of VSD group, 3 of ECD, 3 of TOF and one of PDA + MR, and to all of which the appropriate radical operations were applied. 4. Among the 22 acquired valvular diseases, there were 11 cases of mitral valve diseases [MS; 4, MSr; 3, MRs; 4], 3 cases of aortic valve diseases [AR:1, ARs;1, ASr;1], 4 cases of double valve diseases [MRs+TR; 3, MRs+ARs; 1] and 4 cases of triple valve diseases [MSr+ASr+TR; 3, MSr+Ar+TR; 1]. To all the diseased mitral and aortic valves, artificial valve replacement was applied except one [As], in which valve plication was applied. And to all the diseased tricuspid valve, DeVega annuloplasty was applied. 5. The number of replaced artificial valves were 29 in 25 patients [congenital; 3, acquire; 22]. In MVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 15 of tissue valves [Carpentier-Edward valve; 11, lonescu-Shiley valve; 4] were used. In AVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 2 of tissue valves [Carpentier-Edward valve; 2] were used. 6. Postoperative complications were occurred in 12 cases. Among them 11 cases were recovered with intensive cares, but one patient [VSD + Fistula of Valsalva sinus] was expired with low cardiac out put syndrome.

  • PDF