• 제목/요약/키워드: By-pass Flow Rate

검색결과 79건 처리시간 0.027초

Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해 (Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases)

  • 류영환;구은회;정재은;동경래;최성현;이재승
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

부산신항 용원수로에서의 퇴적물 준설에 의한 용출특성 변화 연구 (A Study on Leaching Characteristics Change for Sediment Dredging in Yongwon Channel, Busan New Port)

  • 추민호;김영도;정원무
    • 대한토목학회논문집
    • /
    • 제37권3호
    • /
    • pp.541-547
    • /
    • 2017
  • 용원해역은 부산신항 개발사업의 일환으로 추진된 북컨테이너부두 조성사업 및 항만 배후단지 조성사업으로 전면 해역이 매립되어 원활한 해수흐름이 차단되고 송정천 하구 지점의 견마도 북쪽 통로를 이용한 선박이동만이 가능한 좁고 긴 수로형태로 변형되었다. 따라서 용원수로에 유입되는 오염물질은 수로에 체류되어 서서히 확산되는 양상을 보일 것으로 판단된다. 본 연구에서는 용원수로 내 준설 전 후 퇴적토 용출실험을 실시한 결과 준설 후에 용출농도가 낮게 나타났으며, 그룹별(A~C) 삭감률을 산정한 결과 T-N의 삭감률은 4.6%, 18.0%, 18.6%로 나타났다. T-P의 삭감률은 24.8%, 24.2%, 44.1%로 나타났다. COD의 삭감률은 18.6%, 19.8%, 38.1%로 용원수로 내 준설 후 수질개선의 효과가 나타났으며, 준설을 통한 용원수로 내 오염원을 제어하기 위한 기초자료로 활용하고자 한다.

소교량 유송잡물 저감시설의 비교 분석 연구 (A Study on the Comparison and Analysis of Debris Reduction System on Small Bridge)

  • 김성중;정도준;강준구;여홍구;김종태
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.31-41
    • /
    • 2016
  • 홍수 시 하천을 따라 이동하는 유송잡물로 인해 교량을 비롯한 구조물 피해가 급증하고 있다. 따라서 본 연구에서는 유송잡물 저감시설인 수직분리대, 우회말뚝, 스위퍼를 제작하여 실험수로에서 저감시설 유무에 대한 집적실험을 실시하였다. 수직분리대는 교량에 집적되는 유송잡물에 평행 흐름을 발생시켜 이를 통과시키는 저감시설로써 목재를 이용해 제작하였으며, 우회말뚝은 유송잡물의 방향을 우회시키는 방식으로 강파이프를 이용해 제작하였다. 스위퍼는 스크류 형태의 원통형 구조물이 흐름에 의한 자력 회전으로 유송잡물을 통과시키는 방법으로 아크릴을 이용하여 제작하였다. 실험은 유송잡물의 경도 및 투하 방법에 따른 집적 정도를 분석하여 저감시설의 집적률을 비교하는 방법으로 수행하였으며 5회 반복실험을 수행하였다. 실험결과 저감시설의 종류, 유송잡물 형태 등에 따라 차이가 있는 것으로 나타났으며 초기 유송잡물이 집적되는 형태에 따라 크게 좌우되는 경우가 많았다. 교량에 대한 직접적인 저감효과는 우회말뚝, 스위퍼, 수직분리대 순으로 나타났지만 우회말뚝의 경우 말뚝에 직접 집적되는 유송잡물로 인하여 흐름교란, 수위 및 하상변동, 말뚝의 유실 등으로 인한 피해가 발생할 수 있으므로 이를 고려한 설계가 필요하다.

혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구 (An Experimental Study of The J-T Cryocooler with Mixed Refrigerant)

  • 이경수;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권1호
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Efficacy of Combining Proximal Balloon Guiding Catheter and Distal Access Catheter in Thrombectomy with Stent Retriever for Anterior Circulation Ischemic Stroke

  • Kim, Sang Hwa;Choi, Jae Hyung;Kang, Myung Jin;Cha, Jae Kwan;Kim, Dae Hyun;Nah, Hyun Wook;Park, Hyun Seok;Kim, Sang Hyun;Huh, Jae Taeck
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.405-413
    • /
    • 2019
  • Objective : We evaluated efficacy of combining proximal balloon guiding catheter (antegrade flow arrest) and distal access catheter (aspiration at the site of occlusion) in thrombectomy for anterior circulation ischemic stroke. Methods : We retrospectively analyzed 116 patients who underwent mechanical thrombectomy with stent retriever. The patients were divided by the techniques adopted, the combined technique (proximal balloon guiding catheter and large bore distal access catheter) group (n=57, 49.1%) and the conventional (guiding catheter with stent retriever) technique group (n=59, 50.9%). We evaluated baseline characteristics (epidemiologic data, clinical and imaging characteristics) and procedure details (the number of retrieval attempts, procedure time), as well as angiographic (thrombolysis in cerebral infarction (TICI) score, distal thrombus migration) and clinical outcome (National Institutes of Health Stroke Scale at discharge, modified Rankin Scale [mRS] at 3 months) of them. Results : The number of retrieval attempts was lower (p=0.002) and the first-pass successful reperfusion rate was higher (56.1% vs. 28.8%; p=0.003) in the combined technique group. And the rate of final result of TICI score 3 was higher (68.4% vs. 28.8%; p<0.01) and distal thrombus migration rate was also lower (15.8% vs. 40.7%; p=0.021) in the combined technique group. Early strong neurologic improvement (improvement of National Institutes of Health Stroke Scale ${\geq}11$ or National Institutes of Health Stroke Scale ${\leq}1$ at discharge) rate (57.9% vs. 36.2%; p=0.02) and favorable clinical outcome (mRS at 3 months ${\leq}2$) rate (59.6% vs. 33.9%; p=0.005) were also better in the combined technique group. Conclusion : The combined technique needs lesser attempts, decreases distal migration, increases TICI 3 reperfusion and achieves better clinical outcomes.

판형 핀을 가진 원통-다관형 열교환기의 열전달 특성에 관한 연구 (Study on Heat Transfer Characteristic of Shell-and-Tube Heat Exchanger with Plate Fin)

  • 임태우;조동현
    • 한국산학기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.46-51
    • /
    • 2009
  • 본 논문은 세 개의 서로 다른 관수(9, 13 그리고 19)를 가지는 원통-판형 핀 관의 원통 측에서의 열전달 성능을 실험적 방법으로 평가하였다 관외를 흐르는 오일은 관내를 흐르는 냉각수에 의해 냉각된다. 오일 쿨러의 원통-다관형 열교환기는 단일 셀 통로와 두 개의 관 통로로 구성되며, 관 내경은 8.82mm, 관 길이는 575mm이다. 오일의 질량 유량은 $1.2{\sim}6.0m^3/h$이며, 냉각수의 질량 유량은 $0.6{\sim}3.0m^3/h$이다. 실험결과 9개의 관수를 가지는 열교환기의 총합 열전달계수는 13개와 19개의 관수의 열전달계수보다 각각 약 1.8배와 2.3배 높게 나타났다.

터보프롭엔진(PT6A-62)의 성능저하 진단을 위한 최적 계측 변수 선정에 관한 연구 (A Study on Optimal Parameter Selection for Health Monitoring of Turboprop Engine (PT6A-62))

  • 공창덕;기자영;장현수;오성환
    • 한국추진공학회지
    • /
    • 제4권4호
    • /
    • pp.87-97
    • /
    • 2000
  • 국내에서 최초로 개발된 기본훈련기 KT-1의 추진기관인 터보프롭 엔진(PT6A-62)을 위한 정상상태 성능모사 덴 진단 프로그램을 개발하였다. 개발된 정상상태 성능해석 프로그램의 검증을 위해 해석 결과를 엔진 제작사에서 제공한 성능 데이터 및 가스터빈 엔진의 성능 모사 프로그램으로 잘 알려진 GASTURB와 비교하였다. 개발된 정상상태 성능해석 프로그램의 검증을 위해 해석 결과를 엔진 제작사에서 제공한 성능 데이터 및 가스터빈 엔진의 성능 모사 프로그램으로 잘 알려진 GASTURB와 비교하였다. 개발된 프로그램의 유용성을 검증하기 위해 다양한 고도, 비행마하수, 부분부하에서의 성능을 해석하였다. GPA(Gas Pess Analysis) 방법은 엔진의 성능 저하를 구성품 효율의 저하와 공기유량의 변화량으로 나타내는 방법이다. 오염, 부식, 침식과 같은 물리적 손상을 탐지하기 위한 최적의 계측변수 선정을 위해 GPA 방법은 유용하다. 본 연구에서는 최적의 계측변수를 선정하기 위해 2가지 방법을 이용하였다 하나는 독립변수의 수를 다르게 하여 계측기 수가 진단에 미치는 영향을 알아보았으며 다음 종속변수의 종류가 미치는 영향을 살펴보았다. 해석 결과에 따르면 압축기 입구 온도 및 압력, 압축기 터빈 입구 온도 및 압력, 동력 터빈 입구의 온도 및 압력과 축마력, 연료유량 등을 측정하여 진단에 이용하는 것이 가장 오차가 적었다.

  • PDF

축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법 (Shear-wave elasticity imaging with axial sub-Nyquist sampling)

  • 오우진;윤희철
    • 한국음향학회지
    • /
    • 제42권5호
    • /
    • pp.403-411
    • /
    • 2023
  • 탄성 영상과 미세 혈류 도플러 영상과 같은 기능성 초음파 영상은 조직의 기계적, 기능적 정보를 제공함으로써 진단 성능을 향상시킨다. 그러나 기능성 초음파 영상의 구현은 데이터 획득 및 처리 시 대용량 데이터 저장과 같은 한계를 야기한다. 본 논문에서는 효율적인 횡탄성 영상 기법을 위해 데이터 획득 양을 절감시키는 서브 나이퀴스트 접근법을 제안한다. 제안하는 방법은 기존 나이퀴스트 샘플링 속도보다 1/3배 낮은 샘플링 속도로 데이터를 획득하고, 주파수 스펙트럼의 주기성을 이용하여 대역 통과 필터링 기반의 보간을 통해 재구성된 Radio Frequency(RF) 신호를 사용하여 횡파 신호를 추적한다. 이때 RF 신호는 67 % 미만의 비대역폭으로 제한된다. 제안하는 접근법을 검증하기 위해 기존 샘플링 속도로 획득한 횡파 추적 데이터를 이용하여 서브 나이퀴스트 샘플링된 RF 신호를 재현하고, 기존 접근법과 횡파 속도 영상을 재구성한다. 정량적 평가를 위해 재구성한 횡파 속도 영상의 군속도, 대조도 잡음 비, 그리고 구조적 유사성 지수를 비교하였다. 우리는 서브 나이퀴스트 샘플링 기반 횡탄성 영상의 가능성을 정성적, 정량적으로 입증하였고, 향후 실시간 3차원 횡탄성 영상 기술에 유용하게 적용 가능할 것으로 기대된다.

Inferring Pedestrian Level of Service for Pathways through Electrodermal Activity Monitoring

  • Lee, Heejung;Hwang, Sungjoo
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1247-1248
    • /
    • 2022
  • Due to rapid urbanization and population growth, it has become crucial to analyze the various volumes and characteristics of pedestrian pathways to understand the capacity and level of service (LOS) for pathways to promote a better walking environment. Different indicators have been developed to measure pedestrian volume. The pedestrian level of service (PLOS), tailored to analyze pedestrian pathways based on the concept of the LOS in transportation in the Highway Capacity Manual, has been widely used. PLOS is a measurement concept used to assess the quality of pedestrian facilities, from grade A (best condition) to grade F (worst condition), based on the flow rate, average speed, occupied space, and other parameters. Since the original PLOS approach has been criticized for producing idealistic results, several modified versions of PLOS have also been developed. One of these modified versions is perceived PLOS, which measures the LOS for pathways by considering pedestrians' awareness levels. However, this method relies on survey-based measurements, making it difficult to continuously deploy the technique to all the pathways. To measure PLOS more quantitatively and continuously, researchers have adopted computer vision technologies to automatically assess pedestrian flows and PLOS from CCTV videos. However, there are drawbacks even with this method because CCTVs cannot be installed everywhere, e.g., in alleyways. Recently, a technique to monitor bio-signals, such as electrodermal activity (EDA), through wearable sensors that can measure physiological responses to external stimuli (e.g., when another pedestrian passes), has gained popularity. It has the potential to continuously measure perceived PLOS. In their previous experiment, the authors of this study found that there were many significant EDA responses in crowded places when other pedestrians acting as external stimuli passed by. Therefore, we hypothesized that the EDA responses would be significantly higher in places where relatively more dynamic objects pass, i.e., in crowded areas with low PLOS levels (e.g., level F). To this end, the authors conducted an experiment to confirm the validity of EDA in inferring the perceived PLOS. The EDA of the subjects was measured and analyzed while watching both the real-world and virtually created videos with different pedestrian volumes in a laboratory environment. The results showed the possibility of inferring the amount of pedestrian volume on the pathways by measuring the physiological reactions of pedestrians. Through further validation, the research outcome is expected to be used for EDA-based continuous measurement of perceived PLOS at the alley level, which will facilitate modifying the existing walking environments, e.g., constructing pathways with appropriate effective width based on pedestrian volume. Future research will examine the validity of the integrated use of EDA and acceleration signals to increase the accuracy of inferring the perceived PLOS by capturing both physiological and behavioral reactions when walking in a crowded area.

  • PDF