• Title/Summary/Keyword: By-pass Flow Rate

Search Result 79, Processing Time 0.031 seconds

Numerical Simulation of a Heat Pump Evaporator Considering the Pressure Drop in the Distributor and Capillary Tubes (분배기와 모세관을 고려한 히트펌프용 증발기 성능 모사)

  • Park, Young-Gi;Ye, Huee-Youl;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.476-486
    • /
    • 2012
  • A simulation program was developed to evaluate the heat transfer performance of a multi-pass fin-tube evaporator, considering the pressure drop in the distributor and capillary tubes. The effect of capillary tube length for each pass was analyzed with various inlet air flow types and distributions. The appropriate capillary tube length distribution and correlation were determined for various inlet air flow types and distributions. The correlated results agreed well with the simulation, with an average error of less than 7%. By applying an optimal capillary tube length distribution, the heat transfer rate was increased by 4~5% compared to cases with uniform tubelength distributions, for each of the inlet air flow types and distributions considered in this study.

Prediction of Flow Stress of Steel in Consideration of Recrystallization (재결정거동을 고려한 강의 유동응력 예측)

  • 이동근;박종진
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.341-348
    • /
    • 1999
  • In the finite elemenet analysis of metal forming problems, the most critical input is the flow stress of workpiece. Conventionally, the flow stress of a metal at elevated temperatures is assumed to be a function of strain, strain rate and temperature, and obtained by experiment. However, if the workpiece is not continuously deformed as in mulit-pass rolling, the flow stress obtained by experiment is no longer valid because it does not consider the microstructure evolution occurring between deformations. In the present study, it was attemped that the flow stress of steel in the austenite region be obtained equations. It was applied to the prediction of flow stress variation at each stand during hot finishing rolling of steel.

  • PDF

A Study of Performance and Internal Flow in a New Type of Sewage Pump

  • Nishi, Yasuyuki;Fukutomi, Junichiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.3
    • /
    • pp.239-247
    • /
    • 2009
  • Sewage pumps are designed with a wide flow channel by, for example, sacrificing some efficiency and reducing the number of blades, in order to prevent plugging with foreign bodies. However, the behavior of foreign bodies which actually flow into a pump is extremely complex, and there are questions about whether the presumed foreign bodies will actually pass through. This paper proposes a new type of sewage pump impeller designed to further improve pump efficiency and performance in passing foreign bodies. This sewage pump impeller has a structure in which the suction flow channel of a closed type non-clog pump is wound in a helical spiral. The focus of this research was to investigate pump performance and internal flow in this single blade sewage pump impeller. The results clearly indicated the following facts: The developed sewage pump impeller exhibits high efficiency over a wide range of flow rates; internal flow of the pump is very complicated; and the internal flow state varies greatly when the flow rate changes.

Numerical Studies of Flow Across End-to-Side Distal Vascular Bypass Graft Anastomoses

  • Kim, Y.H.;Kim, J.H.;Shin, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.339-352
    • /
    • 1992
  • A numerical simulation of the steady and pulsatile flow across the end-to-side anastomosis was performed In order to understand the role of flow dynamics in the preferential bevel opment of distal anastomotic intimal hyperplasla. The finite element technique was employed to solve two-dimensional unsteady pulsatile flow in that region. The results of the steady flow revealed that low shear stresses occur at the proximally occluded host artery and at the recirculation region in the Inner wall just distal to the toe region of the anastomosis. The nor- mal;zed wall shear rate was increased, as was the recirculation zone size in the host artery of the by-pass graft anastomosis, with increased anastomotic junction angle. In order to min imize the size of the low wall shear region which might result in the intimal hyperplasia in the by-pass graft anastomosis, a smaller anastomotic junction angle is recommended. The pulsatile flow simulation revealed flow that regions of low and ascillating mali shear do exist near the anastomosis as In the steady simulation. The shift of stagnation point depends on the pulsation of the flow. As the flow was accelerated at systole, the stagnation point moved downstream, disappered at early diastole and reappeared during late diastole. Low shear stress was also found along both walls of the occluded proximal artery. However, the diastolic flow behavior is quite different from the steady results. The vortex near the occluded artery moved downstream and inwardly during late systole, and disappeared during diastole. Recirculations proximal to the toe and heel regions were significant during diastole. Shear stress oscillation was found along the opposite wall. The results of the present study revealed that tow shear occurs at the proximally occluded host artery aud the recirculation region in the inner wall Just dlstal to the toe region of the anastomosis. The present study suggested that the regions of fluctuated wall shear stress wit flow separation is correlated with the preferential developing regions of anastomosis neointial fibrous hyperplasia.

  • PDF

A Study on the Characteristics of the Liquid-gas Ejector (Liguid-gas Ejector의 구동성능 특성에 관한 연구)

  • Park, Gi-Tae;Jin, Zhen-Hua;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1047-1052
    • /
    • 2008
  • The aim of this paper is that studies on the characteristics of the liquid-gas ejector. Could get data about various model using numerical analysis. Compare and analyze result that get by an experiment and numerical analysis. And studied Characteristics of the ejector. In this paper, Numerical analysis model is gotten divided according to each Throat ratio as three types. Each throat ratio is 0, 4 and 7.5. According to the result that analyze basic model, pressure became lower causing the volume flow rate increase. In CFD studies, Fixed volume flow rate by these result and analyzed ejector performance. As a result, there was no change of pressure to Throat's Enterance, and pressure became low while pass the throat. Since, pressure recovered while passing diffuser. The outer flow velocity did not change greatly to change of volume flow rate. This research expects that is utilized to data for performance elevation hereafter.

  • PDF

발전소 배관지지용 유압완충기 개발

  • Park, Tae-Jo;Koo, Chil-Hyo;Cho, Gwang-Hwan;Lee, Dong-Ryul;Lee, Hyun;Kim, Yeon-Hwan
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.232-238
    • /
    • 1997
  • In this paper, a theoretical method is presented to design a hydraulic control valve system that consist of an important component in the hydraulic snubber. The hydraulic snubber is used essentially to support the piping systems at power plants. To calculate the force due to pressure drop and flow rate in the valve orifice and by-pass hole, Bernoulli equation is used. The Reynolds equation are numerically analyzed in the clearance gap between the valve cone and valve seat to estimate the friction force and leakage flow rate. Based on the detailed theoretical data, we developed successfully the hydraulic snubber for power plants.

  • PDF

Effect on the Deburring of Spring Collet Burr by Abrasive Flow System (입자유동시스템에 의한 스프링콜릿 버의 디버링 효과)

  • 김정두
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.192-197
    • /
    • 1998
  • Abrasive flow machining is useful to abrasive polish a internal or external surface of the free shape dimensional parts, which are used in many fields such as machine tool parts, semi-conductor, and medical component industries. The machining process is that two hydraulic cylinders, which are located surface to surface, are enforce media to the passage between workpiece and tooling part alternately, and then the abrasives included in the media pass the passage and polish the surface of workpiece. The media which is made of polymer and abrasive plays complex have workpiece by its viscoelastic characteristics. In this study, the media for AMF was made by mixing viscoelastic polymer with alumina and silicon carbide abrasive respectively. As a result, alumina include media is also the experiments of deburring the inside burr of in order to analyse the deburring machinability of abrasive flow machining according to various machining parameters which were media flow rate extrusion pressure, passage gap, media viscosity, abrasive content, and abrasive grain size.

  • PDF

Numerical Analysis of Thermal Environment Control in High-Density Data Center (고밀도 데이터센터의 열환경제어를 위한 수치해석)

  • Kwon, Oh-Kyung;Kim, Hyeon-Joong;Cha, Dong-An
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.821-828
    • /
    • 2012
  • Increasing heat generation in CPUs can hamper effective recirculation and by-pass because of the large temperature difference between the exhaust and the intake air through a server room. This increases the overall temperature inside a data center and decreases the efficiency of the data center's cooling system. The purpose of the data center's cooling system is to separate the intake and exhaust air by controlling the computer room air-conditioner(CRAC). In this study, ICEPAK is used to conduct a numerical analysis of a data center's cooling system. The temperature distribution and the entire room are analyzed for different volumetric flow rates. The optimized volumetric flow rate is found for each CPU power. The heat removal and temperature distribution for CPU powers of 100, 120, and 140 W are found to be the best for a volumetric flow rate of $0.15m^3/s$. The numerical analysis is verified through RTI indicators, and the results appear to be the most reliable when the RTI value is 81.

Comparison of Egress Modeling and Experiments for Flow Rate in the Bottleneck (병목현상 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.35-40
    • /
    • 2014
  • Bottleneck occurs as many people crowd into narrow doorway or corridor. Delaying egress time is occurred by bottleneck effect, and it is very important phenomenon on the egress analysis for building fire. An analysis of egress time should includes flow rate for considering bottleneck. Flow rate is numbers of people who pass the narrow gate as door or start point of corridor per unit length and unit time. The flow rate resulted from egress modeling should be approached to the result of experiments. In this study, flow rates from modeling by 'Pathfinder' and experiments was compared. The difference between the result from egress modeling and the one from experiments was verified. The average value of experiments is $4.25N/m{\cdot}s$, and the maximum average value of modeling is $1.55N/m{\cdot}s$.

Numerical investigation into the characteristics of flow and acoustic performances of mufflers for a reciprocating compressor (왕복압축기용 머플러의 유동-음향 성능 특성에 대한 수치적 고찰)

  • Kim, Sanghyeon;Cheong, Cheolung;Kim, Haeseung;Lee, Hyojae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.673-678
    • /
    • 2014
  • In a compressor, highly impulsive pressure fluctuations induced by a reciprocating piston and valves cause noise and vibration to be so critical issues that low noise requirement always challenges engineers developing it. A muffler is frequently used for reducing these impulsive noise components, but has adverse effects on compressor's performance due to additional pressure drop and heat transfer of refrigerant when it pass through the muffler. In this study, compressible full 3-dimensional CFD simulations are performed to investigate both of flow and acoustic performances of a muffler in use for compressors. On a basis of the analysis results, a parametric study using design factors introduced to improve flow and acoustic performances of the existing muffler is carried out. Finally, improved designs are suggested to confirm the current results.

  • PDF