Park, Yong-S.;Han, Sung-H.;Moon, Jung-Tae;Jeon, Suk-Hee
Journal of the Ergonomics Society of Korea
/
v.24
no.3
/
pp.1-10
/
2005
The primary objective of this study is to design input methods for assisting button selection tasks on a PDA screen. Familiar methods in the existing computing environments were investigated to develop aiding methods. Factors manipulated in the experiment included aiding method, button size, and users' prior experience with PDAs. A total of sixteen participants examined the usability of button selection tasks. Two types of button selection tasks were used as experimental tasks; one was selecting a target button, and the other was selecting multiple target buttons consecutively. The results showed that the aiding method and the button size had significant effects on the subjective satisfaction as well as the performance. In addition, users' prior experience with PDAs affected the performance significantly. The interaction between the aiding method and the button size was found to have significant effects on the performance. However, the interaction effect between the button size and the PDA experience was significant on the task performance time only for the multiple button selection tasks. Design considerations were proposed based on the experimental results. These can be applied to the PDA interaction design to make the PDAs more usable.
Journal of Korean Institute of Industrial Engineers
/
v.16
no.2
/
pp.99-107
/
1990
Many accidents related to robot operation occur during the robot teaching process. This paper deals with recommendations for the teach pendant design parameters to enhance safety and performances in human-robot interactions. In order to investigate the optimum location and the size of the emergency stop button on the teach pendant, an experiment was conducted with a simulated teach pendant which can accomodate four different locations and three sizes of the button. Under a simulated emergency condition, the reach time to the emergency stop button was measured at random combination of the location and the size of button. The reach time was significantly affected by the location and the size of the emergency stop button. The fastest average reach time was attained with 1.5 inch-diameter button on the upper center of the teach pendant.
The tactical computer is currently being developed and installed in armored vehicles and tanks for reinforcement. With the tactical computer, Korea Army will be able to grasp the deployment status of our forces, enemy, and obstacles under varying situations. Furthermore, it makes the exchange of command and tactical intelligence possible. Recent studies showed that the task performance is greatly affected by the user interface. The U.S. Army is now conducting user-centered evaluation tests based on C2 (Command & Control) to develop tactical intelligence machinery and tools. This study aims to classify and regroup subordinate menu functions according to the user-centered task performance for the Korea Army's tactical computer. Also, the research suggests an ergonomically sound layout and size of main touch buttons by considering human factors guidelines for button design. To achieve this goal, eight hierarchical subordinate menu functions are initially drawn through clustering analysis and then each group of menu functions was renamed. Based on the suggested menu structure, new location and size of the buttons were tested in terms of response time, number of error, and subjective preference by comparing them to existing ones. The result showed that the best performance was obtained when the number of buttons or functions was eight to conduct tactical missions. Also, the improved button size and location were suggested through the experiment. It was found in addition that the location and size of the buttons had interactions regarding the user's preference.
Kim, Tae-Hun;Han, Seong-Ho;Gwon, Min-Jeong;Lee, Seung-Hui
Journal of the Ergonomics Society of Korea
/
v.25
no.2
/
pp.23-32
/
2006
Window buttons located on a task bar provide information about windows that have been open as well as active. When the number of buttons on the task bar increases, the button size gets smaller and as a result, it is more difficult to identify. This study proposes new alternatives of presenting window buttons to search for a target button efficiently. An experiment was conducted to evaluate the usability of the new. Factors manipulated in the experiment include 'button arrangement methods' and 'order of buttons'. The 'button arrangement methods' factor is composed of three levels, 'one line', 'changeable line', and 'grouping buttons'. The 'order of buttons' factor is composed of three levels, 'fixed order', 'click-right', and 'order control by user'. The results showed that the main effects were significant in search time. In subjective satisfaction, the interaction effect was also significant. The results could be applied to the design of small screens such as PDA or cellular phones.
The objective of the study is to develop selfie sticks to enhance portability and prevent error of pushing mobile phone button. The main target of selfie sticks is women and the size of selfie sticks is too big to put it in their bag. Also when people put mobile phone in a selfie stick, people push its button easily. Sometimes mobile phone is turned off or the volume is controlled because of pushing its button. The researcher focused on designing a solution that enhances portability and preventing error of pushing the button. The researcher understood structure of selfie stick. It consists of a mobile phone supporter and a length adjuster. The researcher designed the mobile phone supporter for enhancing portability and the length adjuster for preventing to push the mobile phone. The researcher designed a part which connects a mobile phone supporter with a length adjuster and made selfie stick fold. Also, sponges are partly put on the mobile supporter. It can reduce situation of pushing the mobile phone button. The selfie stick design from the study has an opportunity to distinguish using the product and carrying it and have people use the selfie stick conveniently.
In this research, three topics were studied for the elderly. The first was the elderly's error characteristics for tracing task and the second was for depth perception. The characteristics were compared with the young's. Twenty two old people and twenty two young people participated in the tracing experiment, respectively. In the depth perception experiment, twenty three old people and twenty two young people participated. A depth perception apparatus and a tracing one were used in the experiment. In the depth perception error, a significant difference was not detected on gender. However significant differences were detected with age and viewing distance. In the tracing error, significant difference was detected with age, also. The third experiment was push-button operation and fifteen old people participated in the experiment. As the result, operation time error was increased with the button size and the moving distance. The result of this study will be able to be considered in its user interface design to reduce the elderly's error while using a product.
Touch input method is unintended difficulties regarding touch and input have increased with touch input methods when compared to using a mouse for input in previously existing menus. This study attempted to analyze usability evaluations according to form and size changes of minimal button forms in button menus. This attempted to verify possibilities through more effective applications of the quantitative performance prediction evaluation model through comparative analysis of Fitts' Law, the representative model of the regression model formula and the interface human performance evaluation method, so that applications can be made in interface designs of touch input methods. Therefore it was significant in that it made reflections on design with consideration given to use user times according to button forms and size changes that can be applied to touch screens.
Purpose: Foreign body (FB) ingestion is common in children, and button battery (BB) ingestion has been increasing in recent years. This study was to identify factors related to outcomes of FB ingestion, particularly BBs in the stomach. We evaluated whether the current recommendations are appropriate and aimed to suggest indications for endoscopic removal of BB in the stomach in young children. Methods: We investigated patient age, shape, size, location of FBs, spontaneous passage time and resulting complications among 76 children. We observed types, size, location of BB and outcomes, and analyzed their associations with complications. Results: Coins and BB were the two most common FBs. Their shapes and sizes were not associated with the spontaneous passage time. Size, spontaneous passage time, and age were also not associated with any specific complications. For BB ingestion, all 5 cases with lithium batteries (${\geq}1.5cm$, 3 V) presented moderate to major complications in the esophagus and stomach without any symptoms, even when the batteries were in the stomach and beyond the duodenum, while no complications were noted in 7 cases with alkaline batteries (<1.5 cm, 1.5 V) (p=0.001). All endoscopies were conducted within 24 hours after ingestion. Conclusion: The type and voltage of the battery should be considered when determining whether endoscopy is required to remove a BB in the stomach. For lithium battery ingestion in young children, urgent endoscopic removal might be important in order to prevent complications, even if the child is asymptomatic and the battery is smaller than 2 cm.
Objective: The aim of this paper is to inquire into the influences form factors and control types affect a search time and comfort at list menu of full touch phone. Background: Various studies have been proceeded that are related to the optimum touch area for enhancing usability of control and legibility in mobile touch device. In the environment of list menu which is widely used to provide various information effectively, however, not only comprehensive consideration for legibility and control is to be seek but also research for control type which is to scroll a list. Method: This study executed form factor experiment to inquire into the influence that font size, height of row and fixed area affect searching time and comfort in the while information processing even if the information on the list is unsorted in alphabetical order. Among the result of form factor experiment, control type experiment was executed by selecting shortest performance time, highest legibility comfort and control comfort. Control type experiment was implemented to figure out the influence which existing flicking type, scrolling bar type, newly established button page type and button raw types affect performance time and subjective comfort depending on location of the information. Results: Font size 12pt, height of row 7mm and fixed area 15mm was shortest performance time and got highest comfort and legibility score in form factor experiment. A Button page which was newly proposed type was shortest performance time and got highest comprehensive comfort in control type experiment. Conclusion: Form factor experiment showed similar results with the study through reading a long passage of character or controlling a grid icon type. However, height of row turned out to affect not only touch area for control but also legibility by ruling space between the lines. Button page type which was newly proposed showed shortest performance time and got highest comprehensive comfort. Because Button page type needs few finger movements than other control types and implements search in the fixed form, unlikely other type which list keeps moving. Application: This study should be applied in deciding form factors and control type for scroll when designing a list menu of full touch phone.
The purpose of this research was to develop an integrated interface for the usability test of systems or products in the design process. It is capable of automatically creating GOMS models which can predict human task performances. It can generate GOMS models to be interacted with the prototype interfaces. It can also effectively manage various design information and various usability test results to be implemented into the new product and/or system design. Thus we can perform usability test for products or system prototypes more effectively and also reduce time and effort required for this test. For usability tests, we established an integrated interface based on GOMS model by the LabVIEW program. We constructed the system that the linkage to GOMS model is available. Using this integrated interface, the menu structure of mobile phone can be constructed easily. User can design a depth and a breath that he want. The size of button and the label of the button is changable. The path to the goal can be defined by the user. Using a designed menu structure, the experiment could be performed. The results of GOMS model and the actual time are presented. Besides, values of operators of GOMS model can be defined as the value that user wants. Using the integrated interface that we developed, the optimal menu structure deducted. The menu structure that user wants can be established easily. The optimal layout and button size can be decided by comparison of numerous menu structures. User can choose the method of usability test among GOMS model and empirical data. Using this integrated interface, the time and costs can be saved and the optimal menu structure can be found easily.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.