• Title/Summary/Keyword: Button battery

Search Result 16, Processing Time 0.028 seconds

A Case of Esophageal Foreign Body by Mercury Button Battery (단추형 수은전지에 의한 식도이물 1례)

  • 이진춘;김창수;박형진;노환중
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.1
    • /
    • pp.73-77
    • /
    • 1999
  • The risk of foreign body by small button-disc battery in children has been increasing because the batteries are widely used in electronic device and plaything and easily contact with children. Foreign body of mercury type button-disc battery, when lodged in the esophagus, leak a caustic solution which causes a rapid necrosis of esophageal mucosa. So it should be removed immediately when the radiologic diagnosis is made. We experienced a case of esophageal foreign body by mercuric disc battery in a 14-month-old male. This case will be discussed with literature review.

  • PDF

Two Cases of Colonoscopic Retrieval of a Foreign Body in Children: A Button Battery and an Open Safety Pin

  • Lee, Eun Joo;Yang, Hye Ran;Cho, Jin Min;Ko, Jae Sung;Moon, Jin Soo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.20 no.3
    • /
    • pp.204-209
    • /
    • 2017
  • Ingestion of foreign body in children is a relatively common problem among paediatric population. The foreign bodies mostly pass spontaneously through the gastrointestinal tract. However, complications can occur according to its anatomical location, the characteristics of the foreign body, and delays in management. Although the cases of ingested button batteries or sharp objects impacted at the gastrointestinal tract can be very serious, there have been very only a few cases have reported colonoscopic removal of these dangerous foreign bodies in adults, and there have been no case reports in children. We report one case of a button battery and one case of an open safety pin, both impacted in the terminal ileum that had moved from the stomach within a few hours of ingestion and were eventually managed by colonoscopy without any complications.

Foreign Body Ingestion in Children: Should Button Batteries in the Stomach Be Urgently Removed?

  • Lee, Jun Hee;Lee, Jee Hoo;Shim, Jung Ok;Lee, Jung Hwa;Eun, Baik-Lin;Yoo, Kee Hwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.19 no.1
    • /
    • pp.20-28
    • /
    • 2016
  • Purpose: Foreign body (FB) ingestion is common in children, and button battery (BB) ingestion has been increasing in recent years. This study was to identify factors related to outcomes of FB ingestion, particularly BBs in the stomach. We evaluated whether the current recommendations are appropriate and aimed to suggest indications for endoscopic removal of BB in the stomach in young children. Methods: We investigated patient age, shape, size, location of FBs, spontaneous passage time and resulting complications among 76 children. We observed types, size, location of BB and outcomes, and analyzed their associations with complications. Results: Coins and BB were the two most common FBs. Their shapes and sizes were not associated with the spontaneous passage time. Size, spontaneous passage time, and age were also not associated with any specific complications. For BB ingestion, all 5 cases with lithium batteries (${\geq}1.5cm$, 3 V) presented moderate to major complications in the esophagus and stomach without any symptoms, even when the batteries were in the stomach and beyond the duodenum, while no complications were noted in 7 cases with alkaline batteries (<1.5 cm, 1.5 V) (p=0.001). All endoscopies were conducted within 24 hours after ingestion. Conclusion: The type and voltage of the battery should be considered when determining whether endoscopy is required to remove a BB in the stomach. For lithium battery ingestion in young children, urgent endoscopic removal might be important in order to prevent complications, even if the child is asymptomatic and the battery is smaller than 2 cm.

Implementation of a Mobile One-Button Game (모바일 원-버튼 게임의 구현)

  • Oh, Sun-Jin;Choi, Se-Young;Lee, Young-Dae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.71-75
    • /
    • 2008
  • The big issue according to the advance of wireless internet is the design of on-line game under mobile computing environment. The current mobile games have constraints in implementation of on-line game due to the low performance processor. small memory size and short battery time. Therefore, nowadays one-button games which are simple and easy to manipulate, have attracted great interests. In this paper, we designed and implemented the trandition Jeki-chaki game, which is a kind of one-line game, using a mobile handset.

  • PDF

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Monitoring System of Blind Areas in a Skiing Resort using a USN (USN을 이용한 스키장 사각 지역 감시 시스템)

  • Lee, Hyung-Bong;Jung, Ui-Min;Park, Lae-Jeong;Moon, Jung-Ho;Chung, Tae-Yun
    • The KIPS Transactions:PartD
    • /
    • v.16D no.2
    • /
    • pp.249-256
    • /
    • 2009
  • This paper introduces an efficient USN (ubiquitous sensor network) for monitoring blind areas in a skiing resort, developed as a part of u-Sport showcase project of Gangwon Province. Blind areas of a skiing resort are dangerous and/or steep areas located aroud ski slopes, which are rarely traveled and not easily seen by a ski patrol. If an accident occurs in such a blind area, the main control center of the sking resort can hardly recognize the accident and provide first aid and rescue services promptly. The blind area monitoring system proposed in this paper monitors a blind area of a skiing resort using five battery-powered sensor nodes each of which has an image sensor on it and wirelessly transmits images around the blind area to the main control center on a regular basis, therebly allowing real-time monitoring of the blind area and prompt rescue services in case of accidents. Additionally, the monitoring system provides an emergency button which skiers injured in the blind area can push. If the button is pushed, an image around the button and an alarm signal are transmitted to the main control center and therefore the main control center can take prompt actions for rescuing the injured skiers.

A Study on the Separation of Mercury from Spent Mercury Batteries (단추형 폐수은 전지로부터 수은 분리에 관한 연구)

  • 손정수;박경호
    • Resources Recycling
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 1994
  • Mercury in spent button type batteries can be separated and recovered with vacuum distillation method. It was found that mercury in the battery began to distill at $150^{\circ}C$ and organic substanced like a packing material was decomposed at$ 300^{\circ}C$. More than 99.9% of mercury contained in the battery was distiled and separated at about $250^{\circ}C$ and 20 torr with 8 hours' reaction time. The dissolution tests of the residue after distillation showed that mercury concentration in the solution were lower than 5 ppb and this values satisfied the environ-mental condition. Also as the furnace heating rate was above $15^{\circ}C$/min, it was found that the spent battery was destroyed because of increased pressure in the battery inside.

  • PDF

Development of a Portable Cardiac Event Recorder (휴대용 심전도 이벤트 기록기 개발)

  • Chun, H.G.;Kim, H.C.;Lee, C.Y.;Kim, I.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.187-188
    • /
    • 1998
  • A low cost, low power, portable cardiac event recorder as a tether-free biological signal processor was developed. Dual channel ECG signals are sampled at 128Hz in 12 bits resolution. Sampled data are continuously recorded in a circular buffer. If event button is pressed, 2 minutes data before and after the event are recorded in 512 Kbyte SRAM. Total 11 events can be recorded. Data can be transferred to PC through RS-232 protocol. It operates for two months by a half AA size 3.6V Lithium battery. The system size is $55\times55\times13[mm^3]$.

  • PDF

Feasibility study for the self powered wireless emergency call button using electromagnetic energy harvesting mechanism (전자기유도방식의 에너지 하베스팅을 이용한 자가발전 무선 비상호출기 구현 연구)

  • Kim, Il-Jung;Choi, Yeon-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.111-119
    • /
    • 2014
  • This paper describes the design and implementation of a electromagnetic energy harvesting mechanism and electronic circuit for autonomous emergency call system. This analysis results show the power output of the proposed harvesting mechanism and circuit up to max power output 5V and it can hold up to 65 msec of the power generation and 10msec of the RF transmission. Based on the these testing results, the implementation of autonomous emergency call device without battery power or any external power source is feasible.