  • For vibration control of stay cables in cable-stayed bridges, viscous dampers are frequently used, and they are regularly installed between the cable and the bridge deck. In practice, neoprene rubber bushings (or of other types) are also widely installed inside the cable guide pipe, mainly for reducing the bending stresses of the cable near its anchorages. Therefore, it is important to understand the effect of the bushings on the performance of the external damper. Besides, for long cables, external dampers installed at a single position near a cable end can no longer provide enough damping due to the sag effect and the limited installation distance. It is thus of interest to improve cable damping by additionally installing dampers inside the guide pipe. This paper hence studies the combined effects of an external damper and an internal damper (which can also model the bushings) on a stay cable. The internal damper is assumed to be a High Damping Rubber (HDR) damper, and the external damper is considered to be a viscous damper with intrinsic stiffness, and the cable sag is also considered. Both the cases when the two dampers are installed close to one cable end and respectively close to the two cable ends are studied. Asymptotic design formulas are derived for both cases considering that the dampers are close to the cable ends. It is shown that when the two dampers are placed close to different cable ends, their combined damping effects are approximately the sum of their separate contributions, regardless of small cable sag and damper intrinsic stiffness. When the two dampers are installed close to the same end, maximum damping that can be achieved by the external damper is generally degraded, regardless of properties of the HDR damper. Field tests on an existing cable-stayed bridge have further validated the influence of the internal damper on the performance of the external damper. The results suggest that the HDR is optimally placed in the guide pipe of the cable-pylon anchorage when installing viscous dampers at one position is insufficient. When an HDR damper or the bushing has to be installed near the external damper, their combined damping effects need to be evaluated using the presented methods.

변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구 (A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer)

  • 김도현;조남욱;윤충호;박필용;박근성
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.53-62
    • /
    • 2017
  • 경제 및 산업의 원천 에너지원인 전력은 생산과 소비의 지역적 상이함으로 장거리 수송을 필수로 하며, 다중환상망(Multi-loop) 형식의 송배전계통으로 전력을 공급한다. 실질적 사용에 앞서, 변전소내 변압기를 통해 변전과정을 거쳐 각 사용처의 특성을 고려하여 전력공급이 이루어지고 있으며 변압기는 본체, 권선, 절연유, 부싱등의 구조로 결합되어 있다. 변전소에서 발생하는 변압기화재는 가구와 상업시설등에 전기공급을 중단시키고 각종 안전사고를 발생시키는 1차 손실뿐만 아니라 2차적으로 경제 손실을 야기한다. 화재의 원인은 부싱 하부파손에 따른 절연유 유출과 약 1초 이내 발화점에 도달하는 절연유에 의한 화재의 연쇄반응으로 파악된다. 화재피해의 최소화를 위해 연기감지기, 자동소화설비 등이 구축되어있으나 감지기의 동작 및 소화가스 방출지연 등으로 화재진화를 위한 골든타임 확보의 부재가 문제되고 있다. 이에 본 연구는 초기 화재진화에 따른 골든타임 확보의 중요성에 따라 화재확산을 방지하고 절연유 누출을 차단하는 능동적 메커니즘의 필요에 따라 수행되었다. 따라서 화염에 의해 팽창하는 고온형상 유지물질과 기계적 화염차단장치를 적용한 부싱방화구조체를 개발하였다. 실제 부싱 및 프렌지규격을 적용하여 제작된 변압기모형에 부싱방화구조체를 설치하여 실규모 화재실험을 수행하였다. 초기화염으로부터 3초내에 정확한 위치와 높이에 부싱방화구조체가 작동함을 확인하였으며 이는 실제 변압기화재 시 화염 확대를 효과적으로 차단할 수 있을 것으로 사료된다.