• 제목/요약/키워드: Bus Control

검색결과 895건 처리시간 0.025초

GPS와 무선통신망을 이용한 지능형 버스 제어시스템에 관한 연구 (A STudy on the Intelligent Bus Control System using GPS and Wireless Communication Network)

  • 홍석주
    • 정보학연구
    • /
    • 제8권1호
    • /
    • pp.83-93
    • /
    • 2005
  • This paper again to present position of a bus that is running in bus government organization small grasp and Can instruct control about the vehicles progress speed in government organization small to bus driver. Therefore, Inform a bus that own wants to ordinary people who carry transfer communication terminal is situated to where present, ad Do by purpose that offer system that inform running information of a bus to ARS and FAX, internet and ordinary people through PC communication. Also, Intelligence style bus control system that see also includes function that do as can guide arrival expectation depot automatically without driver's manufacturing when run a bus.

  • PDF

모터컨트롤센터의 BUS BAR 이상 감지를 위한 실험적 연구 (A study on sensing for abnormality of BUS BAR in motor control center)

  • 김성대
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5838-5842
    • /
    • 2011
  • 본 연구는 고용량의 모터를 구동하기 위한 모터컨트롤센터(MCC)의 내부 구조 중 각 상(R,S,T)의 BUS BAR의 온도와 BUS BAR 볼트 체결부의 온도변화가 모터컨트롤센터의 노후화 및 진동에 따라 어떠한 차이가 있는지를 적외선 온도센서가 설치된 온도측정용 2차원 기구부를 설계 제작하고 모터컨트롤센터의 내부에 설치하여 BUS BAR의 온도 및 전류 변화량을 상시 모니터링 하였다. 실험을 통하여 부하에 따른 BUS BAR의 온도 변화를 BUS BAR 나사 체결부위를 중심으로 측정하였으며, BUS BAR의 온도변화와 소모 전류에 대한 비례관계를 확인할 수 있었다. 또한 이러한 비접촉식 2차원 온도측정 시스템을 모터컨트롤센터 내부에 장착하면 부하의 과전류로 인한 온도 상승이나 접촉 불량 등으로 발생될 수 있는 정전이나 화재 사고를 예방할 수 있을 것으로 기대된다.

버스운행관리 및 수송전략에 관한 연구 (A Study on the Bus Operation Management and Transport Strategy)

    • 한국항만학회지
    • /
    • 제13권2호
    • /
    • pp.323-332
    • /
    • 1999
  • The bus should supply an equal service to the whole community as feeder trip. However the existing bus route can not supply an effective feeder service in spite of the changes in the latent demand by the variety of regional structural change. This study aimed to establish the concept which frames the bus operation and management to cope with the latent demand to the bus. This study tackled this evidence by analyzing the transportation problems in terms of the urban growth emphasizing the following issues ; First, the strategy to improve the bus operation Second the land use control appropriate for the public transportation network Third economical range to justify the bus operation Second, the land use control appropriate for the public transportation network Third, economical range to justify the bus operation Fourth, the allowance for the private transportation mode On the latter part, the difference on the bus operation was compared to determine the range within which the bus operation could be justified. This study would provide some implications to improve the management for bus operation and fundamental information to develop the bus operation system.

  • PDF

퍼지제어를 이용한 비선형 2기 5모선 전력계통의 안정화 (Stabilization of nonlinear two-generator five-bus power systems using fuzzy control)

  • 문운철
    • 제어로봇시스템학회논문지
    • /
    • 제6권1호
    • /
    • pp.42-49
    • /
    • 2000
  • This paper presents the application of a FARMA controller to stabilization of nonlinear Two-Generator Five-Bus power Systems. The control rules and the membership functions of the FARMA controller are generated automatically without using any plant model high complexity and severe nonlinearity of power systems are introduced and two-Machine Five -Bus Power system stabilization problem is formulated. The simulation results demonstrate the effectiveness and application possibility of the FARMA controller to the control problem of high order and nonlinear plants.

  • PDF

DC 전력시스템에서의 Voltage Bus Conditioner의 제어기법 비교 (The Comparison of Two Control Algorithm for a Voltage Bus Conditioner in a DC Power Distribution System)

  • 나재두;이용근
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.47-53
    • /
    • 2006
  • A Voltage Bus Conditioner (VBC) is used to mitigate the voltage transients on a common power distribution bus. The VBC described here utilises inductive storage and unlike its counter part with capacitive storage, it can employ the entire stored energy towards transients' mitigation. The performances of adaptive duty ratio control and sliding mode control have been compared. The simulation results (with the package SABER) indicate that the sliding mode control results in the shortest and the smallest bus voltage excursions.

Analog Controller for Battery to Stabilize DC-bus Voltage of DC-AC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.66-67
    • /
    • 2014
  • Stabilization of the DC bus voltage is an important task in DC-AC microgrid system with renewable energy source such as solar system. A battery energy storage system (BESS) has become a general solution to stabilize the DC-bus voltage in DC-AC microgrid. This paper develops the analog BESS controller which requires neither computation nor dc-bus voltage measurement, so that the system can be implemented simply and easily. Even though others methods can stabilize and control the DC-bus voltage, it has complicated structure in control and low adaptive capability. The proposed topology is simple but is able to compensate the solar source variation and stabilize the DC-bus voltage under any loads and distributed generation (DG) conditions. In addition, the design of analog controller is presented to obtain a robust system. In order to verify the effectiveness of the proposed control strategy, simulation is carried out by using PSIM software.

  • PDF

대용량 통신위성 전력조절을 위한 전력제어장치개발 (Power Control & Distribution Unit Development for Bus Power Control of Communication Satellite with Large Capacity)

  • 최재동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.85-89
    • /
    • 2004
  • This paper presents Power Control and Distribution Unit development of GEO satellite with 3kW power output. The sensing error of bus voltage produce control signal of the shunt switch assembly and battery power converter, and the tolerance of error signals generated decide the stability of proposed system. The dynamic characteristics of main bus according to the load changing and the control logic of FPGA are simulated. In order to verify the proposed design, the simulation and experimental results for solar array shunt switch, battery power converter and bus controller are shown.

  • PDF

병렬 펄스 부하를 갖는 직류 전력시스템을 위한 Voltage Bus Conditioner의 전류 센서 없는 제어 (Current Sensorless Control of the Voltage Bus Conditioner for a DC Power System with Parallel Pulsed Power Loads)

  • 이병헌;장한솔;나재두;김영석
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1617-1624
    • /
    • 2012
  • A DC power system has many loads with varied functions. Also, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, Voltage Bus Conditioner(VBC) without any current sensors is proposed to damp the bus voltage transients by parallel pulsed loads. The proposed control approach requires only one voltage sensor and carries out both the functions of damping the bus voltage transients and maintaining the level of energy stored. The proposed control technique has been implemented on a TMS320F2812 Digital Signal Processor(DSP). Simulated results by a Matlab Simulink and experimental results are presented which verify the control principles and demonstrate the practicalty of the approach.

VME bus를 이용한 Step & Scan형 노광장비의 Control System 구성 (VME bus based control system for step & scan exposure tool)

  • 최용만;오병주;김도훈;정해빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.672-675
    • /
    • 1997
  • This paper proposes a structure of the control system for the step & scan exposure tool. The step & scan exposure tool is used for the manufacturing process of the semiconductor DRAM memory of giga bit. The control system employs the VME bus instead of the conventional ISA bus so that all control signals and data can be managed separately by the 4 VME-PCs for fast and fault-free flow of signals for multi-tasking. A high speed I/O card is equipped for the real-time monitoring and control of the sub module equipment. Then all the subsystems are integrated and aligned for the operation of the step & scan exposure tool with the VME bus and, I/O card.

  • PDF

분산형 에너지 관리시스템의 직렬접속 BUS 적용 (Serial interconnection BUS in the distributed energy management systems)

  • 김정호;김정훈;채영도
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.389-393
    • /
    • 1987
  • This paper describes the configuration of serial interconnection BUS, BitBUS, for Energy Management Systems, and it provides low cost, high performance approach in distributed data acquisition and control applications.

  • PDF