• Title/Summary/Keyword: Burst Type

Search Result 155, Processing Time 0.019 seconds

Physiologic Phonetics for Korean Stop Production (한국어 자음생성의 생리음성학적 특성)

  • Hong, Ki-Hwan;Yang, Yoon-Soo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.17 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • The stop consonants in Korean are classified into three types according to the manner of articulation as unaspirated (UA), slightly aspirated (SA) and heavily aspirated (HA) stops. Both the UA and the HA types are always voiceless in any environment. Generally, the voice onset time (VOT) could be measured spectrographically from release of consonant burst to onset of following vowel. The VOT of the UA type is within 20 msec of the burst, and about 40-50 msec in the SA and 50-70 msec in the HA. There have been many efforts to clarify properties that differentiate these manner categories. Umeda, et $al^{1)}$ studied that the fundamental frequency at voice onset after both the UA and HA consonants was higher than that for the SA consonants, and the voice onset times were longest in the HA followed by the SA and UA. Han, et $al^{2)}$ reported in their speech synthesis and perception studies that the SA and UA stops differed primarily in terms of a gradual versus a relatively rapid intensity build-up of the following vowel after the stop release. Lee, et $al^{3)}$ measured both the intraoral and subglottal air pressure that the subglottal pressure was higher for the HA stop than for the other two stops. They also compared the dynamic pattern of the subglottal pressure slope for the three categories and found that the HA stop showed the most rapid increase in subglottal pressure in the time period immediately before the stop release. $Kagaya^{4)}$ reported fiberscopic and acoustic studies of the Korean stops. He mentioned that the UA type may be characterized by a completely adducted state of the vocal folds, stiffened vocal folds and the abrupt decreasing of the stiffness near the voice onset, while the HA type may be characterized by an extensively abducted state of the vocal folds and a heightened subglottal pressure. On the other hand, none of these positive gestures are observed for the SA type. Hong, et $al^{5)}$ studied electromyographic activity of the thyroarytenoid and posterior cricoarytenoid (PCA) muscles during stop production. He reported a marked and early activation of the PCA muscle associated with a steep reactivation of the thyroarytenoid muscle before voice onset in the production of the HA consonants. For the production of the UA consonants, little or no activation of the PCA muscle and earliest and most marked reactivation of the thyroarytenoid muscle were characteristic. For the SA consonants, he reported a more moderate activation of the PCA muscle than for the UA consonant, and the least and the latest reactivation of the thyroarytenoid muscle. Hong, et $al^{6)}$ studied the observation of the vibratory movements of vocal fold edges in terms of laryngeal gestures according to the different types of stop consonants. The movements of vocal fold edges were evaluated using high speed digital images. EGG signals and acoustic waveforms were also evaluated and related to the vibratory movements of vocal fold edges during stop production.

  • PDF

The Probability of Solar Proton Events (SPEs) depending on solar and interplanetary type II bursts

  • Youn, Sae-Poom;Moon, Young-Jae;Park, Jin-Hye
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.28.4-29
    • /
    • 2011
  • Solar Proton Events (SPEs, ${\geq}\;10\;cm^{-1}s^{-1}sr^{-1}$ with >10 MeV) are very important for space weather forecasting. It is well known that they are associated with solar flares and/or CME-driven shocks. Especially, the CME-driven shocks have been observed as solar and interplanetary type II bursts. In this study, we estimated the occurrence probability of SPEs depending on three groups: (1) metric, (2) decameter-hectometric (D-H), and (3) meter-to-kilometric (m-to-km) type II bursts. For this work, we used SPEs and all available type II burst data in 1996-2004. The primary findings of this study are as follows. First, the majority (77%) of the m-to-km type II bursts are associated with SPEs and its probability is noticeably higher than D-H type II bursts probability strongly depend on longitude: eastern (0%), center(45%), and western (33%) for X-class associated metric type II bursts, eastern (15%), center (55%), and western (50%) for X-class associated D-H type II bursts, eastern (17%), center (77%), and western (64%) for X-class associated m-to-km type II bursts. Third, for m-to-km type II bursts, the SPE probability increases with CME speed: 400km/s${\leq}$V <1000km/s (36%), 1000km/s ${\leq}$V<1500km/s (40%), 1500km/s${\leq}$V (66%). Finally, we expect that these results will be used for setting up more reasonable solar proton event forecasting models.

  • PDF

Optimization on Weight of High Pressure Hydrogen Storage Vessel Using Genetic Algorithm (유전 알고리즘을 이용한 고압 수소저장용기 중량 최적화)

  • Lee, Y.H.;Park, E.T.;Kim, J.;Kang, B.S.;Song, W.J.
    • Transactions of Materials Processing
    • /
    • v.28 no.4
    • /
    • pp.203-211
    • /
    • 2019
  • In this study, the weight of type IV pressure vessel is optimized through the burst pressure condition using the finite element analysis (FEA) based on the genetic algorithm (GA). The optimization design variables include the thickness of composite layers and the winding angles. The optimized design variables are validated using the numerical simulations for the pressure vessel. Consequently, the weight is decreased by about 6.5% as compared to the previously reported results for Type III pressure vessel. Additionally, a method which reduces the entire optimization time is proposed. In the original method, the population size is constant across all generations. However, the proposed method could reduce the workload through the reduction of the population size by half for every 25 generations. Thus, the proposed method is observed to increase the weight by about 0.1%, however, the working time for the optimization could be decreased by about 46.5%.

Preparation of Core-shell Type Nanoparticles of Poly($\varepsilon$-caprolactone) /Poly(ethylene glycol)/Poly( $\varepsilon$-caprolactone) Triblock Copolymers

  • Ryu, Jae Gon;Jeong, Yeong Il;Kim, Yeong Hun;Kim, In Suk;Kim, Do Hun;Kim, Seong Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.5
    • /
    • pp.467-475
    • /
    • 2001
  • A triblock copolymer based on $poly(\varepsilon-caprolactone)$ (PCL) as the hydrophobic part and poly(ethylene glycol) (PEG) as the hydrophilic portion was synthesized by a ring-opening mechanism of ${\varepsilon}-caprolactone$ with PEG containing a hydroxyl group at bot h ends as an initiator. The synthesized block copolymers of PCL/PEG/PCL (CEC) were confirmed and characterized using various analysis equipment such as 1H NMR, DSC, FT-IR, and WAXD. Core-shell type nanoparticles of CEC triblock copolymers were prepared using a dialysis technique to estimate their potential as a colloidal drug carrier using a hydrophobic drug. From the results of particle size analysis and transmission electron microscopy, the particle size of CEC core-shell type nanoparticles was determined to be about 20-60 nm with a spherical shape. Since CEC block copolymer nanoparticles have a core-shell type micellar structure and small particle size similar to polymeric micelles, CEC block copolymer can self-associate at certain concentrations and the critical association concentration (CAC) was able to be determined by fluorescence probe techniques. The CAC values of the CEC block copolymers were dependent on the PCL block length. In addition, drug loading contents were dependent on the PCL block length: the larger the PCL block length, the higher the drug loading content. Drug release from CEC core-shell type nanoparticles showed an initial burst release for the first 12 hrs followed by pseudo-zero order release kinetics for 2 or 3 days. CEC-2 block copolymer core-shell type nanoparticles were degraded very slowly, suggesting that the drug release kinetics were governed by a diffusion mechanism rather than a degradation mechanism irrelevant to the CEC block copolymer composition.

Internal Stress and Physical Properties of Multi-layered Paper (다층지의 내부응력과 물성)

  • Won, Jong Myoung
    • Journal of Forest and Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.89-100
    • /
    • 1998
  • The study was carried to investigate the change of internal stress and physical properties of paper by the mutiplying of paper structuring that is an useful means to maximize the performance and use of the fiber raw material. The effects of recycled fiber on the physical properties of multiplied paper also were studied. The beating increased the internal stress of single layered paper, while filler loading decreased the internal stress. Multiplying the structure of paper decreased the internal stress and the most of physical properties except for tear index. It was found that the properties of paper could be changed by the pulp type, beating and the combination of raw materials. The introduction of filler in the middle and/or outer layer could improved the internal stress, tensile index, tear index and burst index. The addition of recycled fiber increased the opacity and stiffness of paper in both single layered and multiplied paper. Multiplying the structure of paper improved the air permeability and stiffness, while decreased burst index.

  • PDF

Fast Acoustic Radiation Force Impulse Imaging Using Non-focused Transmission in Medical Ultrasound Imaging (초음파 의료 영상에서 비집속 송신을 이용한 고속 음향 복사력 임펄스 영상법)

  • Choi, Seung-Min;Park, Jeong-Man;Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.151-160
    • /
    • 2012
  • In medical ultrasound imaging, elasticity imaging helps to diagnose tumors such as cancer. This paper is concerned with the application of acoustic radiation force to soft tissue of interest to implement elasticity imaging. In order to reduce the data acquisition time, instead of relying on transmit focusing, a plane wave of burst type is transmitted to apply the acoustic radiation force simultaneously to an entire imaging region to be observed. A homogeneous phantom experiment confirms that increasing the transmit excitation duration instead of employing transmit focusing generates a high enough acoustic radiation force to obtain elasticity images. It is found, however, that a different displacement versus time characteristic is observed unlike the case of using a conventional focused acoustic radiation force. Experimental results obtained through the use of an ultrasound phantom and a bovine liver show that lesions can be correctly differentiated.

A Study on the Modularization of LED Driver for Illumination Using a Fly-Back Converter (플라이백 컨버터를 이용한 조명용 LED Driver의 모듈화 연구)

  • Choi, Jin-Bong;Kim, Kwan-Woo;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.504-513
    • /
    • 2009
  • This paper proposes the new type LED driver modularization for illumination LED driver. The proposed LED driver circuit insulates a hot GND of AC input power and a cold GND of LED driver part by using a fly-back converter. In order to control easily the current of the LED, the fly-back converter is operated in the discontinuous mode with excellent dynamic characteristics, and the characteristics of the LED are verified after the closed loop control is performed using a KIA2431. The LED driver module allows the wide AC power input ranges and realizes the burst dimming function which directly regulates a PWM control IC. This paper describes the operation principle of the LED driver module and it is proved the usefulness through the real model with experimentation. Besides, this paper proposes the multi-channel LED driver which the miniaturized and modularized LED driver module are connected by parallel, and verified its propriety by experiments.

Development of an Electric Pulp Tester with Constant Current Source (정 전류원을 이용한 치수 검사기의 개발)

  • 김재성;남기창;김수찬;이승종;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • Electric stimulation of teeth has been used for assessing pulp vitality. The principle is based upon the assumption that a subject feels the pain produced by electrical current stimulation of intradental nerve. Because of very high and wide range of impedance of the enamel, it is very difficult to determine stimulation levels regardless of teeth status. Most pulp testers adopt voltage stimulation method and thus, their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation due to different enamel thickness. And it is also necessary to test teeth vitality with a wide current range regardless of tooth impedance. In this study, we constructed a burst-wave type pulp tester to reduce the pain using a current stabilizing circuit with the maximum current of 150 uA.

Circuit Design and Performance Analysis of CCFL Dimming Controller With Frequency Modulation

  • Kim, Cherl-Jin;Ji, Jae-Geun;Yoon, Shin-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.201-205
    • /
    • 2004
  • The CCFL dimming control methods are generally used lamp current regulation or average current adjustment method feeding the CCFL inverter. Inverter operation frequency is higher than resonant frequency for safe operation. In this study, we design the half-bridge type series and parallel resonant converter circuit that switches at variable frequency modulation methods to control the output power. This method has advantages such as low EMI and reduced harmonics, and it is convenient for dimming control using a microprocessor. The validity of this study is confirmed from the simulation and experimental results.

A Study on Waveform Parameter for the Electrotactile Stimulation (경피(經皮) 전기자극(電氣刺戟)을 파형(波形) 파라메터에 관한 연구(硏究))

  • Ham, K.K.;Min, H.K.;Lee, H.J.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.198-202
    • /
    • 1992
  • In this paper, we have performed an experiment to obtain an optimized electric stimulation condition on the tip or a ringer skin. The desired parameters for stimulation of the finger tip skin are waveforms, frequency, stimulation intensity, duty cycle. As a result, when the finger skin was stimulated with monophasic, biphasic, and differntial phasic, the most appropriate condition was 200 to 250[Hz] in frequency, 10 to 25[%] in duty cycle. Burst type pulse was more sensitive effect than that of continuous pulse methode.

  • PDF