• 제목/요약/키워드: Burning property

검색결과 60건 처리시간 0.024초

삼초(三焦)와 영위(營衛)의 상관성(相關性) (The Relation of Three Burning Space And Nutrient & Defensive Qi)

  • 문성식;강정수
    • 혜화의학회지
    • /
    • 제9권1호
    • /
    • pp.105-112
    • /
    • 2000
  • Three burning space concentrating mainly on the text of ${\ll}NeiChing{\gg}$, we got this conclusion by looking at a longitudial perspective of three burning space function, nutrient & defensive qi creation, movement and numbers. 1. Longitudial movement is the law of the universe, by looking at oriental medicine by the thought of heaven and man unity we can tell that longitudial movement concept is used to analyze the physiology of our body. And we can look at our body in a cubic movement suck as top and bottom, left and right, outside and inside, internal and external, upward and downward movement. 2. In Nei Ching the concept of three burning space is seperated in to four different types of three burning space which are three burning space as a fu, three burning space as a water metabolism and excretion organ, and three burning space by its position. 3. nutrient & defensive qi's movement in the channel is the same as the twelve regular channels movement in our body, nutrient qi circulates the yang part twenty five during the day and circulates the ying part twenty five times during the night. Since channel functions corresponds with the sun, moon, and the stars the ups and downs of nutrient & defensive qi's property varies with the difference of the periods. 4. By comparing nutrient & defensive qi's production and property with three burning space's positional property, we can see that three burning space's positional property comes out from the longitudial movement of nutrient & defensive qi.

  • PDF

Mg Alloy의 Burning과 Plasma Electrolyte Oxidation 표면처리에 대한 연구 (The Characteristic in Mg Alloy with Burning and Plasma Electrolyte Oxidation Surface Treatment)

  • 유재인;최순돈;장호경
    • 한국진공학회지
    • /
    • 제19권5호
    • /
    • pp.326-330
    • /
    • 2010
  • Plasma electrolyte oxidation (PEO) 표면처리된 Mg 합금을 scanning electron microscopy (SEM) 방법으로 표면에 형성된 산화 막을 조사 분석하였다. 측정은 상온에서 수행하였다. Burning 및 PEO 방식의 표면처리 방법을 통해 제작 된 시료의 산화막을 SEM, EDS 및 I-V 측정을 통해 분석하였다. 그 결과 burning 방식의 표면처리가 PEO보다 내식성이 떨어지는 단점이 있지만, 전도성이 부여되는 결과를 나타낸다.

산화성고체-조연제 혼합물의 연소성에 관한 연구 (A Study on Combustion Property of Oxidizing Solid-Combustible Support Mixtures)

  • 송영호;강민호;정국삼
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.71-75
    • /
    • 2003
  • The purpose of this study was to review the factors that influence on the combustion experiment of oxidizing solid such as mixing ratio of oxidizing solid and combustible support content ratio of oxidizing solid, ambient temperature, maturing time, combustible support, and additives. The 30g mixing compound samples of oxidizing solid and combustible support were tested with different mixing ratios. As a result, the Infest burning time was measured when mixing ratio was 4 (oxidizing solid) : 1 (combustible support). And the burning time was decreasing as the ambient temperature and maturing time were increasing.

표준모타를 이용한 추진제 연소특성 분석 (Combustion Property Analysis of Propellant using Standard Motor)

  • 박의용;최성한;황종선
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2003
  • 메인모타 추진제의 연소속도를 예측하기 위하여 표준모타를 제작하고 지상연소시험을 수행하였다. 이를 위하여 중, 소형 모타의 시험에 적합한 지상연소시험장을 구축하고 경량화된 6 inch 급의 표준모타를 개발하여 여러 차례의 시험에 적용하였고, 메인모타의 연소속도와 비교하였다. 그 결과 표준모타를 이용하는 방법이 기존의 연소속도 측정 방법에 비해 메인모타의 연소속도를 비교적 잘 반영하는 것으로 나타나, 앞으로의 추진제 개발 활동 및 양산품의 품질보증 활동에 적극 활용할 계획이다.

  • PDF

Single Port 하이브리드 로켓의 고체연료 물질전달수(B Number)를 고려한 연소특성 연구 (Influences of B Number Effect on the Burning Rate of Solid Fuel in Single Port Hybrid Rocket)

  • 이정표;김수종;유우준;조성봉;문희장;김진곤
    • 한국항공우주학회지
    • /
    • 제36권3호
    • /
    • pp.264-270
    • /
    • 2008
  • 하이브리드 로켓 고체 연료의 연소율(Burning Rate)을 묘사하는 후퇴율은 연료 유속, 산화제 유속과 더불어 연료길이의 함수로 나타내어지나 일반적으로 가장 영향이 큰 산화제 유속만의 함수로 모델링된다. 그러나 이는 연료가 갖고 있는 고유의 열화학적 특성에 대한 영향이 내포되어 있지 않아 다양한 연료에 대한 공통된 관계를 나타내기 어렵다. 본 연구에서는 고체연료의 열화학적 특성과 연소에 따른 공기역학적 특성이 고려된 물질전달수(B Number)를 도입하여 다양한 연료에 공통으로 사용될 수 있는 연소율 관계식을 제시하고, 물질전달수 내의 공기역학적 특성의 영향을 분석하였다. 물질전달수와 산화제 유속의 함수로 표현된 연소율 식은 고정된 실험 지수항과 상수항으로 PMMA, PP 및 PE의 연소율을 모두 묘사할 수 있었고, 연소율 관계식에서 B Number에 내포된 공기역학적 효과는 미미하였다.

PVC 바닥상재용 광경화형 내열 코팅액의 제조 및 응용에 관한 연구 (Manufacture and Application of UV-Cured Anti-cigar burning Coating Compounds for PVC Tile)

  • 박보람;하진욱
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.608-613
    • /
    • 2010
  • 본 연구는 건축용 바닥재로 널리 이용되는 PVC 상재의 표면을 열에 의한 손상으로부터 보호하기 위하여 기존에 사용하는 광경화형 우레탄-아크릴 수지에 내열성(anti-cigar burning)을 향상시킨 광경화형 수성도료 개발에 관한 것이다. PVC 바닥상재용으로 사용되는 내열기능성이 없는 우레탄-아크릴 수지에 인계화합물을 주원료로 합성한 내열재, 구아니딘을 주원료로 합성한 내열재, 일시적 방염제로 사용되는 제 2인산암모늄을 수지의 양 대비 함량(wt%)을 10, 20, 30%로 변화하여 첨가한 후 배합하여 수지의 내열성을 향상시킨 코팅액을 제조하였다. 제조한 코팅액은 코팅층의 두께조절이 가능한 Bar-coating을 사용하여 PVC 바닥상재에 코팅한 후, 내열성, 부착력, 내화학성, 코팅두께 등의 코팅층 표면물성을 평가하였다. 연구결과, 수지에 인계화합물을 주원료로 합성한 내열재 30%를 혼합하여 제조한 코팅액을 Bar-coater No.12로 코팅한 코팅표면이 열에 의한 손상이 가장 적고, 부착력 100%, 내화학성 양호로 가장 좋은 물성을 보였다. 전반적으로 내열재 함량이 높고, 코팅 두께가 두꺼울수록 내열성이 우수한 것으로 나타났다.

Friability 시험을 이용한 HTPE 및 HTPB 추진제의 충격 민감도 (Impact Sensitivity of HTPE & HTPB Propellants using Friability Test)

  • 김창기;유지창;민병선
    • 한국추진공학회지
    • /
    • 제15권1호
    • /
    • pp.29-34
    • /
    • 2011
  • Hydroxyl terminated polyether(HTPE) 추진제는 전술용 모터에 현재까지도 적용되고 있는 HTPB/AP 추진제를 대체할 수 있는 추진제로서 최근에 개발되고 있다. 본 연구에서는 HTPE와 HTPB 추진제에 대한 파쇄성 시험을 수행하고 그 결과를 분석하였다. 추진제의 파쇄성은 바인더함량, 기계적 특성 및 연소속도에 의해 영향을 받았으며 연소속도가 증가할수록 기계적 인성이 낮아질수록 파쇄성은 증가하는 경향을 보였다.

폐콘크리트계 미분말의 소성조건에따른 수화성 회복 (Recovering Hydration Performance of Cementitious Powder by Concret Waste according to Burning Temperature)

  • 강태훈;정민수;안재철;강병희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.81-87
    • /
    • 2003
  • The purpose of this study is the development of a recycling process to recover the hydrated ability of cement hydrate which accounts for a large proportion of cementitious powder by concrete waste in order to recycle cementitious powder by concrete waste as recycle cement. Therefore, after having theoretical consideration based on the properties of high-heated concrete, we consider the properties of hydration of cementitious powder in hardened mortar under various temperature conditions. As a result of experiment, it is revealed that an effective development of recycling cement is possible since the cementitious powder by concrete waste recovers a hydraulic property during burning at $600^{\circ}C$ or $700^{\circ}C$. And it is shown that the fluidity of mortar decreases rapidly as the burning temperature of recycle cement increases. however, the improved effect of fluidity is predominant if adding the additive such as fly-ash or blast furnace slag.

  • PDF

결합제 함량에 따른 HTPB/AP/Al 추진제의 특성 연구 (A Study on Properties of HTPB/AP/Al Propellant to Contents of Bonding Agents)

  • 이영우;하수라;장명욱;김태규;이정준;손현일
    • 한국연소학회지
    • /
    • 제22권3호
    • /
    • pp.47-52
    • /
    • 2017
  • The propellant tile and crack which account for the greatest proportion of solid rockets are profoundly affected by viscosity and mechanical properties of solid propellant. In this paper HTPB/AP/Al system propellant has been researched for the viscosity, mechanical properties and burning properties with type and contents of bonding agents. The viscosity of propellant was changed significantly depending on the type and contents of bonding agents, and mechanical properties of HTPB/AP/Al system propellant were also varied. Considering both lower viscosity and stable mechanical properties, the optimum type and contents of bonding agents can be identified as the main factors to the HTPB/AP/Al system propellant.

합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度) (Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권4호
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF