• Title/Summary/Keyword: Burn through

Search Result 243, Processing Time 0.03 seconds

Effective Delivering Method of Umbilical Cord Blood Stem Cells in Cutaneous Wound Healing (제대혈 유래 중간엽 줄기 세포를 이용한 피부 창상 치료시 세포 투여 방법에 따른 창상치유 효과의 비교)

  • Park, Sang Eun;Han, Seung Bum;Rah, Dong Kyun;Lew, Dae Hyun
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.519-524
    • /
    • 2009
  • Purpose: This study was conducted to establish the most effective method of cell therapy by comparing and analyzing the level of wound healing after various cell delivery methods. Methods: Human mesenchymal stem cells were administered using 5 different methods on full thickness skin defects which were deliberately created on the back of 4 - week old mice using a 8 mm punch. Different modes of administration, cell suspension, local injection, collagen GAG matrix seeding, fibrin, and hydrogel mix methods were used. In each experiment group, $4{\times}105$ mesenchymal stem cells were administered according to 5 deferent methods, and were not for the corresponding control group. Results: The wound healing rate was fastest in the local injection group. The wound healing rate was relatively slow in the collagen matrix group, however, the number of blood vessels or VEGF increased most in this group. Conclusion: For rapid wound healing through wound contraction, it is advantageous to administer MSC by the local injection method. For the healing process of a wide area, such as a burn, the seeding of cells to collagen matrix is thought to be effective.

Lessons Learnt from an 11-year Experience with Lymphatic Surgery and a Systematic Review of Reported Complications: Technical Considerations to Reduce Morbidity

  • Ciudad, Pedro;Escandon, Joseph M.;Manrique, Oscar J.;Bustos, Valeria P.
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.227-239
    • /
    • 2022
  • Complications experienced during lymphatic surgery have not been ubiquitously reported, and little has been described regarding how to prevent them. We present a review of complications reported during the surgical management of lymphedema and our experience with technical considerations to reduce morbidity from lymphatic surgery. A comprehensive search across different databases was conducted through November 2020. Based on the complications identified, we discussed the best approach for reducing the incidence of complications during lymphatic surgery based on our experience. The most common complications reported following lymphovenous anastomosis were re-exploration of the anastomosis, venous reflux, and surgical site infection. The most common complications using groin vascularized lymph node transfer (VLNT), submental VLNT, lateral thoracic VLNT, and supraclavicular VLNT included delayed wound healing, seroma and hematoma formation, lymphatic fluid leakage, iatrogenic lymphedema, soft-tissue infection, venous congestion, marginal nerve pseudoparalysis, and partial flap loss. Regarding intra-abdominal lymph node flaps, incisional hernia, hematoma, lymphatic fluid leakage, and postoperative ileus were commonly reported. Following suction-assisted lipectomy, significant blood loss and transient paresthesia were frequently reported. The reported complications of excisional procedures included soft-tissue infections, seroma and hematoma formation, skin-graft loss, significant blood loss, and minor skin flap necrosis. Evidently, lymphedema continues to represent a challenging condition; however, thorough patient selection, compliance with physiotherapy, and an experienced surgeon with adequate understanding of the lymphatic system can help maximize the safety of lymphatic surgery.

Research on Fashion Design Using the Formative Features of Ecology (에콜로지의 조형적 특징을 활용한 패션디자인 연구)

  • Park, Hanhim
    • Journal of Fashion Business
    • /
    • v.26 no.2
    • /
    • pp.15-27
    • /
    • 2022
  • The purpose of this study is to perform research of ecology concepts expressed in fashion and to propose a new ecology fashion design based on the results. As a specific research method, first, to determine the concept of ecology, the contents related to ecology were extracted and organized through literature research, and then a fashion collection research was conducted to acquire basic design data, such as silhouettes, materials, details, and colors. From WGSN, and a total of 57 images were selected and used as basic data for the design suggestions. As a result of collecting the collection images, it was found that cotton or denim fabrics were mainly used, and in particular, the frequency of use was high mainly for bright tones. The use of chambray, lace, and wrinkles, was also frequent, and the use of expression techniques using burn-out, bleach, and bleaching effects or parts, or entire dyeing was often noticeable. The colors showed neutral and pastel-toned characteristics, and the silhouette was mainly composed of long silhouettes centered on maxi, such as a top or calf based on the knee, rather than a mini. Fabrics for the final designs were linen and sappan wood, and they were used for the dye and red was used as the overall color. The silhouettes were simplified, and care was taken to prevent unnecessary waste, such as paper or materials, from being generated during the production stage. We tried to achieve the purpose of eco-logy by refraining from excessive trimming, except for essential subsidiary materials, such as zippers.

Endoscopic Laser Irradiation Condition of Urethra in Tubular Structure (관형 요도 조직 대상 내시경적 레이저 조사 조건 연구)

  • Hwarang, Shin;Seonghee, Lim;Yeachan, Lee;Hyun Wook, Kang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.85-91
    • /
    • 2023
  • Stress urinary incontinence (SUI) occurs when abdominal pressure increases, such as sneezing, exercising, and laughing. Surgical and non-surgical treatments are the common methods of SUI treatment; however, the conventional treatments still require continuous and invasive treatment. Laser have been used to treat SUI, but excessive temperature increase often causes thermal burn on urethra tissue. Therefore, the optimal conditions must be considered to minimize the thermal damage for the laser treatment. The current study investigated the feasibility of the laser irradiation condition for SUI treatment using non-ablative 980 nm laser from a safety perspective through numerical simulations. COMSOL Multiphysics was used to analyze the numerical simulation model. The Pennes bioheat equation with the Beer's law was used to confirm spatio-temporal temperature distributions, and Arrhenius equation defined the thermal damage caused by the laser-induced heat. Ex vivo porcine urethral tissue was tested to validate the extent of both temperature distribution and thermal damage. The temperature distribution was symmetrical and uniformly observed in the urethra tissue. A muscle layer had a higher temperature (28.3 ℃) than mucosal (23.4 ℃) and submucosal layers (25.5 ℃). MT staining revealed no heat-induced collagen and muscle damage. Both control and treated groups showed the equivalent thickness and area of the urethral mucosal layer. Therefore, the proposed numerical simulation can predict the appropriate irradiation condition (20 W for 15 s) for the SUI treatment with minimal temperature-induced tissue.

Evaluation of the Remineralization Capacity of Water-based Silver Fluoride

  • Gwangsuk Kim;Juhyun Lee;Haeni Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.80-87
    • /
    • 2024
  • Silver diamine fluoride, which can arrest dental caries, is alkaline and may cause mild soft tissue irritation. Water-based silver fluoride has a neutral pH, which is closer to the physiological range, and is biocompatible for use in the oral environment. This study aimed to evaluate the effect of water-based silver fluoride on remineralizing early enamel lesions by comparing it with other fluoride agents through microhardness and quantitative light-induced fluorescence measurements. An in vitro study with intact bovine incisors was performed. Artificial enamel lesions were induced and subjected to microhardness and quantitative light-induced fluorescence testing. Specimens were randomly divided into 4 groups for treatment. The specimens in group I were treated with water-based silver fluoride and potassium iodide, group II with silver diamine fluoride and potassium iodide, group III with sodium fluoride varnish, and group IV with distilled water. After 8 days of pH cycling, the specimens were subjected to microhardness and quantitative light-induced fluorescence testing. Water-based silver fluoride and silver diamine fluoride showed the greatest increases in microhardness and quantitative light-induced fluorescence, with no significant differences between the two. Sodium fluoride varnish also exhibited a significant increase in microhardness and quantitative light-induced fluorescence, but the differences were smaller than those for water-based silver fluoride and silver diamine fluoride. Water-based silver fluoride is considered useful in a clinical setting for remineralizing enamel lesions, with the advantages of no risk of tissue burn and improved taste and smell.

Effects of Low-power Laser and TDP on the Cutaneous Wound Healing (피부상처 치유에 대한 저에너지레이저와 특정전자파의 효과)

  • Ahn So-Youn;Park Sang-Ock
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.1-18
    • /
    • 1997
  • The purpose of this study is to investigate the effects of the low power Helium Neon-Infra Red(HeNe-IR) laser and the special electromagnetic therapeutic apparatus stimulation, which is usually designated as TDP by using the initial of Tending Diancibo Pu which is the Chinese inscribed with English, on wound healing in rat. The seventy-five Sprague-Dawley adult female and male rats were assigned to the experimental and control groups. Each rat was anesthetized with pentobarbital sodium, and three full-thickness incisions with 12mm length wert made on the back of the half cf the rats and three deep second degree burns were made on the back of the remainder of the rats. From 34 hours after being injured, the rats of the experimental laser group were irradiated with the 157mW electric power HeNe-IR laser for 2 minutes every day and the rats of the experimental TDP group were stimulated with TDP irradiation with the 4km spot distance for 20 minutes every day during the 17 days. The rats were sacrificed and the wound parts of its were incised on the first day, 4th day, 7th day, 10th day and 17th day respectively after the beginning of wound treatment with laser and TDP irradiation. The incised wound parts were processed appropriately for the light microscopic and electron microscopic examination. The length of incised wound was measured with microcaliper before the wound part was incised. There was a significant decrease in the length of the incised wound of the experimental laser and TDP group, compared with that of control group at 4th day, 7th day and 10th day(p<0.01) after surgery. Through the histological examination of the wound site, the more rapid epithelialization and collagen formation in experimental groups were showed, compared with control group. The histological results were analyzed and summarized as the follows; The epidermis begins to be regenerated and the granulation tissue begins to be changed to the mature pattern in the H-E stained incised skin of the laser and TDP treatment group on the 4th day. The epidermis shows the complete regeneration and the granulation tissue in the dermis in mostly to be matured in the laser and TDP treatment group on the 7th day, compared with control group. The chronic inflammatory cells are oberved and the necrosis of the collagen fibers are partially observed in control group on the 10th day. The dermis of the laser and TOP treatment group reveals relatively compactly arranged collgen bundles with the mature collagen fibers on the 10th day. The epidermis and dennis of the laser and TDP group are repaired normally and the hair follicles are well regenerated on the 17th day. The mild edema and the granulation tissue is observed in the dermis of the control groups and the delayed treatment process is observed on the 17th day. The Most of proliferated collagen fibrils are found to be compact and regular in electron micrograph of burn skin of the laser treatment group on the 10th day hut the interstitial eadema and some inflammatory cells are found in the control group. The above results suggest that through the visual and histological examination the epithelized epithelium and the proliferation of the collagen liters in the dermis occur very effectively with the low power laser treatment and the TDP treatment in the incised wound healing and the burn wound healing.

  • PDF

Study on Horn-shaped Moxa Treatment in the Annals and Anthologies of Joseon-Korea (조선 왕실의료문헌과 문집에 나타난 우각구법(牛角灸法) 연구)

  • Oh, Jun-Ho;Kim, Jin-Hee;Ahn, Sang-Woo
    • The Journal of Korean Medicine
    • /
    • v.31 no.4
    • /
    • pp.38-48
    • /
    • 2010
  • Objectives: Moxa treatment has outstanding effects that are frequently facilitated in a clinical setting, and it is also known to have positive effects for immunity and relief of pain through various studies. Currently, moxa treatment has become diversified in many ways. One of the moxa treatment techniques that was frequently used during the Joseon Dynasty was Woogakgubeop (牛角灸法, horn-shaped moxa treatment). This articles aims to disclose the fact that the Woogakgubeop is the technique applicable to the origin of the Large moxa treatments of today. Also, the writings of Woogakgubeop recorded in the royal medical documentations, such as the Chronicles of the Royal Families of the Joseon Dynasty, the Seungjeonwonilgi (The Daily Records of Royal Secretariat) and others, are analyzed and the characteristics of the Woogakgubeop are cleared through it. Methods: From the royal medical documents, the Chronicles of the Royal Families of the Joseon Dynasty and the Seungjeonwonilgi, articles related Woogakgubeop were extracted and analyzed. Records of each document were facilitated for the DB search. In addition to these two documents, the records of written literature were surveyed as well. The written literature are appropriate to express the experiences of intellectuals at the time. Results and Conclusions: 1. Considering that Woogakgubeop is a single therapy, there exists relatively many records in addition to the specialized medical documents, and through them, it is known that Woogakgubeop was a widely known therapy in the middle to later parts of Joseon in general. 2. Woogakgubeop is a method that addresses problems contained within the existing moxa treatment techniques. By enlarging the size of the mugwort wick, it strengthens the heat energy of the moxa treatment to reduce the frequency of applying moxa treatment. When undertaking the method to empty the wick inside the mugwort, the pain of a fever patient will be reduced and burn damage to the skin is minimized. 3. Wind-cold type weakness and other general moxa treatment techniques have been used for various symptoms detailed, including chest pain, tinnitus, carbuncle, cellulites, cold sense of leg, colic, diarrhea and other illnesses. In addition, it may generate strong fever, and was used to implement the Yeonjebeop (煉臍法). 4. Woogakgubeop is applicable to the origin of Large moxa treatment of today and it provides important bibliographic base thereof.

A case of venous stasis ulcer treated by subfascial endoscopic perforator ligation and split thickness skin graft (내시경적 교통정맥 결찰술과 부분층 피부이식술로 치료한 정맥성 궤양의 치험례)

  • Moon, Seong ho;Lee, Jong wook;Koh, Jang hyu;Seo, Dong kook;Choi, Jai koo;Jang, Young chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.336-340
    • /
    • 2009
  • Purpose: The wound of a patient who has chronic venous insufficiency is easy to recur. Also they develop a complication even after the conservative therapy or skin graft. We have to diagnose the venous stasis ulcer correctly and remove the cause to improve the effectiveness of treatment. We operated endoscopic perforating vein ligation and splitt thickness skin graft on a patient with venous stasis ulceration on right leg. Methods: A 26 year old male patient who had a scalding burn on his right leg in July 2005 checked into our hospital in March 2008. Even though he got three operations - the split thickness skin graft - at different clinics, the wound did not heal. The size of the wound was 12 by $8cm^2$ and granulation with edema and fibrosis had been formed. We kept observation on many collateral vessels and perforating vein through venogram and doppler sonography and firmly get to know that the wound came with chronic venous insufficiency. After a debridement and an application of VAC$^{(R)}$ for two weeks, the condition of granulation got better. So we proceeded with the operation using subfascial endoscopic perforating surgery and split thickness skin graft. Results: Through the venogram after the operation, we found out that the collateral vessels had been reduced compared to the previous condition and the widened perforating vein disappeared. During a follow up of 6 months, the patient did not develop recurrent stasis ulcer and postoperative complications. Conclusion: Subfascial endoscopic perforator ligation is relatively simple technique with a low complication rate and recurrence rate. Split thickness skin graft with subfascial endoscopic perforator surgery can be valuable method for treating severe venous stasis ulcers.

Characteristics of Ti-SPAC as Fluidizing Phase Photocatalyst (Ti-구형활성탄의 유동상 광촉매 특성 평가)

  • Lee, Joon-Jae;Suh, Jeong-Kwon;Hong, Ji-Sook;Park, Jin-Won;Lee, Jung-Min
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.375-381
    • /
    • 2006
  • In this sturdy, spherical activated carbon(SPAC) contained $TiO_2$ was made by ion-exchanged treatment and heat treatment for applying fluidizing bed system. The ion-exchange resin was treated by $TiCl_3$ aqueous solution. The treated resin and raw resin were heat-treated under nitrogen condition to convert into Ti-SPAC. During the heat-treatment, burn-off weight amounts and the element were measured by means of TGA and TGA/MS, individually. The physicochemical properties of Ti-SPAC was characterized by means of XRD, SEM, EDS, BET, EPMA, ESR, intensity and titanium content. The Ti-SPAC had spherical shape with diameter size about $350{\mu}m{\sim}400{\mu}m$ and $617m^2/g$ specific surface area. Structure of $TiO_2$ in Ti-SPAC was anatase and rutile form. Also, $TiO_2$ on SPAC were found that the $TiO_2$ were uniformly distributed through EPMA analysis. Moreover, the Ti-SPAC showed indirect photocatalyst activity estimation through ESR analysis, characteristics of photocatalyst potentially. Over all results, Ti-SPAC was used in fluidizing bed UV/photocatalyst system to remove HA(Humic Acid). That results were HA removal efficiency was about 70% and Ti-SPAC intensity was preserved during reaction. Ti-SPAC showed practical possibility as photocatalyst in fluidizing bed system.

Study of Combustion Characteristics with Variations of Combustion Parameter in Ultra-Lean LPG Direct Injection Engine (연소제어인자의 변화에 따른 직접분사식 초희박 LPG엔진의 연소특성 연구)

  • Park, Yun Seo;Park, Cheol Woong;Oh, Seung Mook;Kim, Tae Young;Choi, Young;Lee, Yong Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.6
    • /
    • pp.607-614
    • /
    • 2013
  • Nowadays, automotive manufacturers have developed various technologies to improve fuel economy and reduce harmful emissions. The ultra-lean direct injection engine is a promising technology because it has the advantage of improving thermal efficiency through the deliberate control of fuel and ignition. This study aims to investigate the development of a spray-guided-type lean-burn LPG direct injection engine through the redesign of the combustion system. This engine uses a central-injection-type cylinder head in which the injector is installed adjacent to the spark plug. Fuel consumption and combustion stability were estimated depending on the ignition timing and injection timing at various air-fuel ratios. The optimal injection timing and ignition timing were based on the best fuel consumption and combustion stability.