• Title/Summary/Keyword: Burn Rate

Search Result 212, Processing Time 0.027 seconds

Cesium Release Behavior during the Thermal Treatment of High Bum-up Spent PWR Fuel (고연소도 경수로 사용후핵연료의 열처리에 따른 세슘 방출거동)

  • Park, Geun-Il;Cho, Kwang-Hun;Lee, Jung-Won;Park, Jang-Jin;Yang, Myung-Seung;Song, Kee-Chan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.1
    • /
    • pp.53-64
    • /
    • 2007
  • The dynamic release behavior of Cs from high burn-up spent PWR fuel was experimentally performed under the conditions of a thermal treatment process such as voloxidation and sintering conditions. In voloxidation process, influence of the oxidation and reduction atmosphere on the Cs release characteristic using fragment type of spent fuel heated up to $1,500^{\circ}C$ was compared. In sintering process, temperature history effect on Cs release behavior was evaluated using green pellet under 4% $H_2/Ar$ environment. Temperature range for complete Cs release from spent fuel fragment under voloxidation condition was about $800^{\circ}C{\sim}1,200^{\circ}C$, but that of green pellet under the reduction atmosphere was $1,100^{\circ}C{\sim}1,400^{\circ}C$. Key parameters on Cs release behavior from spent fuel was powder formation as well as the diffusion rate of Cs compound to grain boundary and fuel surface.

  • PDF

A Survey on the Occupational Health Nursing Activities for primary care (산업간호사의 의료행위 직무지침서 활용 및 의료행위직무 수행실태)

  • Yun, Soon Nyoung;Kirn, Soon Lae;Kim, Young Im;Song, Young Sook;An, Jung Hae;June, Kyung Ja;Cho, Tong Ran;Kim, Jeong Hees
    • Korean Journal of Occupational Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.5-17
    • /
    • 2000
  • The occupational health nursing guideline for primary care was developed by the Korean Academic Society of occupational health nursing and the organization for occupational health nurses (currently known as the Korean Association of Occupational Health Nurses) in 1993. Since then, there have been many changes in the health care environment and job performance of occupational health nurses. Appropriate revisions are necessary of the guidelinea based on this background. The purpose of this study was to describe the use of the occupational health nursing guideline for primary care and to analyze the characteristics of primary care activities by occupational health nurses. The questionnaire was mailed to 150 occupational health nurses(OHNs) with the response rate of 64%. The results can be summarized as follows; 1. 65.6% of OHNs have been using the guideline for primary care and 75.9% of them agreed that the guideline was be helpful for their job. 2. Common symptom care, emergency care and chronic illness care were more frequently implemented than occupational disease care by OHNs. In manufacturing industries, emergency care was more frequently implemented than chronic illness care in contrast to the service industries. 3. Most frequent common symptoms treated by OHNs were indigestion, diarrhea, abdominal pain, headache, and coughing. In the case of chronic illness, OHNs more frequently treated diseases of the gastro-intestinal system, skin and sensory organs, and the respiratory system. Emergency care for bruises, burn, and abrasions was more frequently provided. VDT syndrome was the most common occupational disease cared by OHNs in manufacturing and service industries. 4. OHNs prescribed the medicine for external application more frequently than internal medicine. Remedy for colds, analgesics, vitamins, and digestives were more frequently used. From these results, we suggest that the guideline should be revised to emphasize the activities consisting problem finding such as health assessment, physical examinations, monitoring and screening, and to renew the drug list in the range of over- the counter medication (OTC). In the future, the guideline will include the strategies for the role as the case manager.

  • PDF

Characteristics of Pediatric and Adolescent Trauma-Database Review of Single Level Trauma Center in Gangwon Province

  • Lee, Tae Han;Jung, Pil Young;Kwon, Hye Youn;Shim, Hongjin;Jang, Ji Young;Bae, Keum Seok;Kim, Seongyup
    • Journal of Trauma and Injury
    • /
    • v.30 no.3
    • /
    • pp.75-79
    • /
    • 2017
  • Purpose: Although trauma is the most common cause of death under age 18, Korean national pediatric trauma data has lack of clinical data. This study is to prepare manpower resources, equipment, and make a correct policy decision on pediatric trauma victims Methods: The study enrolled 528 patients under age 16 with traumatic injury visited Wonju Severance Christian Hostpital Trauma Center, from February 12, 2015 to December 31, 2016. We analyzed the distribution of gender, age, place and time of the accident, injury mechanism, injury severity, and injured organ by medical record. Results: The major injury mechanisms were blunt injury in 485 (91.90%), penetrating injury in 27 (5.10%), burn in 13 (2.50%), near drowning in 2 (0.40%), and foreign body ingestion in 1 (0.20%). Ninety-seven (18.4%) patients were injured at home and 67 (12.7%) patients were injured at school. The overall mortality rate was 1.13% (n=6). 5 mortalities were related to automobile accident and one was fall down. Mean Injury Severity Score (ISS) was 4 (2, 8). No statistical significance was observed in the mean ISS between each age group. The peak time of accident occurrence was between 16 and 17 o'clock. The mean ISS was higher in blunt injury group than penetrating injury with statistical significance ($6.50{\pm}7.60$ vs. $3.00{\pm}8.10$; p<0.05). The most common injury site was upper extremity. Mean ISS was highest in thorax injury. However, mean ISS of thorax injury was higher with statistical significance only compared with face, neck and upper extremity injury. Conclusions: We reported our pediatric trauma patients data of our hospital level I trauma center, which is the only one level I trauma center of Gangwon Province. These data is useful to prevent and prepare for pediatric trauma.

Effectiveness of Simple Trauma Team Activation Criteria on Prognosis of Severe Trauma Patients (단순 외상팀 활성화 조건이 중증 외상 환자의 치료 결과에 미치는 영향)

  • Lee, Dong Keon;Lee, Kang Hyun;Cha, Kyoung Chul;Park, Kyoung Hye;Choi, Han Joo;Kim, Hyun;Hwang, Sung Oh
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2009
  • Purpose: The goal of this study was to compare the outcome of the after trauma team (AfterTT) group to the before trauma team (BeforeTT) group. Methods: All trauma patients who visited to emergency room (ER) between July 1, 2006 and February 29,2008 based on trauma registry, with systolic blood pressure (SBP) < 90 mmHg or GCS < 9 were included in this study. We compared the amount of packed RBC transfusion, the ER stay time, the ER visit to CT evaluation time, the ER visit to operation time, the length of ICU stay, the length of hospital admission and the survival discharge rate between the AfterTT group and the BeforeTT group. Patients with brain injuries had little chance of survival. Burn patients, who visited the ER 24 hours after injury and patients who were dead on arrival (DOA) were excluded from this study. Results: Total of 93 patients were included in this study: 42 in the AfterTT group and 51 in the BeforeTT group. The AfterTT group and the Before TT group showed no differences in Revised Trauma Score (RTS) and mean age. The amount of packed RBC transfusion was lower in the AfterTT group, but no statistically significant difference was noted (AfterTT 11${\pm}$11units, BeforeTT 16${\pm}$15units, p=0.136). The ER visit to operation time was shorter in the AfterTT group, but there were no statistically significant difference between the groups (AfterTT 251${\pm}$223 minutes, BeforeTT 486${\pm}$460 minutes, p=0.082). The length of ICU stay was shorter in the AfterTT group, but the difference was not statistically significant (AfterTT 11${\pm}$12 days, Before TT 15${\pm}$30 days, p=0.438). The length of Hospital admission was shorter in the AfterTT group (AfterTT 43${\pm}$37 days, BeforeTT 68${\pm}$70 days, p=0.032), but this difference was not statistically significant. Conclusion: Simple Trauma team activation criteria decreased the amount of packed RBC transfusion and the hospital admission duration. Hemodynamic instability (SBP < 90 mmHg) and decreased mental state (GCS<9) are good indices for activating the trauma team.

Numerical Study of Evaporation and Ignition of in-line Array Liquid Droplets (액적 배열의 증발과 착화에 관한 수치해석적 연구)

  • 김충익;송기훈
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • The spreading fire of very small floating particles after they are ignited is fast and t therefore dangerous. The research on this area has been limited to experiments and global simulations which treat them as dusts or gaseous fuel with certain concentration well m mixed with air. This research attempted micro-scale analysis of ignition of those particles modeling them as liquid droplets. For the beginning, the in-line array of fuel droplets is modeled by two-dimensional, unsteady conservation equations for mass, momentum, energy and species transport in the gas phase and an unsteady energy equation in the liquid phase. They are solved numerically in a generalized non-orthogonal coordinate. The single step chemical reaction with reaction rate controlled by Arrhenius’ law is assumed to a assess chemical reaction numerically. The calculated results show the variation of temperature and the concentration profile with time during evaporation and ignition process. Surrounding oxygen starts to mix with evaporating fuel vapor from the droplet. When the ignition condition is met, the exothermic reactions of the premixed gas initiate a and burn intensely. The maximum temperature position gradually approaches the droplet surface and maximum temperature increases rapidly following the ignition. The fuel and oxygen concentration distributions have minimum points near the peak temperature position. Therefore the moment of ignition seems to have a premixed-flame aspect. After this very short transient period minimum points are observed in the oxygen and fuel d distributions and the diffusion flame is established. The distance between droplets is an important parameter. Starting from far-away apart, when the distance between droplets decreases, the ignition-delay time decreases meaning faster ignition. When they are close and after the ignition, the maximum temperature moves away from the center line of the in-line array. It means that the oxygen at the center line is consumed rapidly and further supply is blocked by the flame. The study helped the understanding of the ignition of d droplet array and opened the possibility of further research.

  • PDF

EPMA Analysis of Inter-reaction Layer in Irradiated U3Si-Al Fuels (EPMA를 이용한 U3Si/Al 조사 핵연료의 반응층 분석)

  • Jung, Yang-Hong;Yoo, Byung-Ok;Kim, Hee-Moon;Park, Jong-Man;Kim, Myung-Han
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.355-362
    • /
    • 2004
  • Fission products and Inter reaction layer of $U_3Si-Al$ dispersion fuel, irradiated in HANARO research reactor with 121 kW/m of maximum liner power and 63 at% of average burn-up, was characterization by EPMA (Electron Probe Micro Analyzer). The fuel punching system developed by Irradiated Materials Examination Facility (IMEF) has used to make these samples for the EPMA. With this system a very small and thin specimen which is 1.57 mm in diameter and 2 mm in thickness respectively has been fabricated to protect the EPMA operator from high radioactive fuel and to mini-mize the equivalent dose rate less than 150 mSv/h. EPMA was performed to observe layers of sectional, Inter-reaction and oxide with specimens of cutting and polished. Stoichiometry in the Inter-reaction layer with $16{\mu}m$ of thickness was $U_{2.84}$ Si $Al_{14}$ with calibration of $UO_2$ and $U_{3.24}$ Si $Al_{14.1}$ with calibration of standard specimen. metallic precipitates in this layer were not observed using fission products examination.

Quantitative Analysis of Damage Impacts in case of Bunkering NH3 from Tank Lorry to Fishing Vessel (어선-탱크로리 간의 NH3 이적 시 누출에 따른 정량적 피해영향분석)

  • Lim, Sang-Jin;Choi, Bu-Hong;Lee, Yoon-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.10-20
    • /
    • 2022
  • About 21% of domestic chemical accidents are caused by transport vehicles for the past 10 years in Korea. Also, ammonia is a chemical substance with the largest number of accidents, 82 out of 672. In this study, supposed seasonal alternative scenario and worst scenario in case of releasing ammonia during bunkering it from tank lorry to fishing vessel and interpreted seasonal impact and range through Python, ALOHA, Probit analysis. Radiation impact range of possibility for 2nd burn and for maximum radiation in winter scenario, which is one of the alternative scenarios, was the highest(range: 41m, radiation: 5.01kW/m2) while overpressure impact was less than minimum standard of impact. And toxicity impact range(EPRG-2) of the summer scenario was the widest(5.0km) and took a very high death rate near accident area(port area, tourist area) according to Probit analysis. the wort scenario had a similar impact and range of summer scenario.

Review of Production, Husbandry and Sustainability of Free-range Pig Production Systems

  • Miao, Z.H.;Glatz, P.C.;Ru, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1615-1634
    • /
    • 2004
  • A review was undertaken to obtain information on the sustainability of pig free-range production systems including the management, performance and health of pigs in the system. Modern outdoor rearing systems requires simple portable and flexible housing with low cost fencing. Local pig breeds and outdoor-adapted breeds for certain environment are generally more suitable for free-range systems. Free-range farms should be located in a low rainfall area and paddocks should be relatively flat, with light topsoil overlying free-draining subsoil with the absence of sharp stones that can cause foot damage. Huts or shelters are crucial for protecting pigs from direct sun burn and heat stress, especially when shade from trees and other facilities is not available. Pigs commonly graze on strip pastures and are rotated between paddocks. The zones of thermal comfort for the sow and piglet differ markedly; between 12-22$^{\circ}C$ for the sow and 30-37$^{\circ}C$ for piglets. Offering wallows for free-range pigs meets their behavioural requirements, and also overcomes the effects of high ambient temperatures on feed intake. Pigs can increase their evaporative heat loss via an increase in the proportion of wet skin by using a wallow, or through water drips and spray. Mud from wallows can also coat the skin of pigs, preventing sunburn. Under grazing conditions, it is difficult to control the fibre intake of pigs although a high energy, low fibre diet can be used. In some countries outdoor sows are fitted with nose rings to prevent them from uprooting the grass. This reduces nutrient leaching of the land due to less rooting. In general, free-range pigs have a higher mortality compared to intensively housed pigs. Many factors can contribute to the death of the piglet including crushing, disease, heat stress and poor nutrition. With successful management, free-range pigs can have similar production to door pigs, although the growth rate of the litters is affected by season. Piglets grow quicker indoors during the cold season compared to outdoor systems. Pigs reared outdoors show calmer behaviour. Aggressive interactions during feeding are lower compared to indoor pigs while outdoor sows are more active than indoor sows. Outdoor pigs have a higher parasite burden, which increases the nutrient requirement for maintenance and reduces their feed utilization efficiency. Parasite infections in free-range pigs also risks the image of free-range pork as a clean and safe product. Diseases can be controlled to a certain degree by grazing management. Frequent rotation is required although most farmers are keeping their pigs for a longer period before rotating. The concept of using pasture species to minimise nematode infections in grazing pigs looks promising. Plants that can be grown locally and used as part of the normal feeding regime are most likely to be acceptable to farmers, particularly organic farmers. However, one of the key concerns from the public for free-range pig production system is the impact on the environment. In the past, the pigs were held in the same paddock at a high stocking rate, which resulted in damage to the vegetation, nutrient loading in the soil, nitrate leaching and gas emission. To avoid this, outdoor pigs should be integrated in the cropping pasture system, the stock should be mobile and stocking rate related to the amount of feed given to the animals.

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF

Clinical Experience of $VNUS^{(R)}Closure$ fast in Treatment of Varicose Vein: Comparison with Traditional Radiofrequency Ablation (하지정맥류 치료를 위한 2세대 고주파 열폐쇄술($VNUS^{(R)}Colosure$ fast)과 기존의 고주파 열폐쇄술($VNUS^{(R)}Closure$ plus)의 임상치험 비교 분석)

  • Kim, Woo-Shik;Lee, Jeong-Sang;Jeong, Seong-Cheol;Shin, Vong-Chul
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.635-641
    • /
    • 2010
  • Background: Radiofrequency endovenous ablation of incompetent saphenous vein has gaining popularity over the conventional ligation and stripping as a minimally invasive technique. The latest version of radiofrequency endovenous catheter, $VNUS^{\circledR}Colosure$ fast VNUS medical Technologies, San Jose, CA, adopted a segmental ablation system, instead of continous pullback, is designed to reduce treatment time in comparison with the previous model $VNUS^{\circledR}Colosure$ plus VNUS medical Technologies, San Jose, CA. The purpose of this study is to compare the difference between two endovenous radiofrequency ablation systems in terms of treatment efficacy and complication rates. We analyze the initial efficacy and complication rates of $VNUS^{\circledR}Colosure$ fast with $VNUS^{\circledR}Colosure$ plus. Material and Method: Between June 2006 and August 2009, $VNUS^{\circledR}Colosure$ plus was performed to treat varicose vein on 59 limbs in 41. patients and $VNUS^{\circledR}Colosure$ fast was performed on 76 limbs in 67 patients. We retrospectively compared in both group with sex, mean treatment time, mean treatment diameter, conjugated treatment, and complications after the procedure. Result: All patient were symptomatic and diagnosed as varicose vein and underwent level 2 clinical classification with color duplex scan. The mean treatment time for the great saphenous vein was significantly less with $VNUS^{\circledR}Colosure$ fast ($17.0{\pm}6.5min$) than $VNUS^{\circledR}Colosure$ plus ($62.7{\pm}9.8min$). There was no significant difference in 1 yr closure rate between groups (p=0.32). Minor complications such as skin burn, thrombophlebitis, ecchymosis, hematoma, cellulitis, tenderness, and there were not different between the groups. Conclusion: Both $VNUS^{\circledR}Colosure$ fast and $VNUS^{\circledR}Colosure$ plus are effective methods of endovenous saphenous ablation. $VNUS^{\circledR}Colosure$ fast is superior to the previous model with less treatment time preserving compatible efficacy and complications. The efficacy of $VNUS^{\circledR}Colosure$ fast for long term closure rate remains to be established.