• Title/Summary/Keyword: Burn Model

Search Result 149, Processing Time 0.029 seconds

Development of Flight Model of Segmented Nut Type Holding and Release Mechanism Using Burn Wire Cutting Method for On-orbit Verification (열선절단형 분리너트식 구속분리장치의 궤도검증을 위한 비행모델 개발)

  • Lee, Myeong-Jae;Lee, Yong-Keun;Kang, Suk-Joo;Oh, Hyun-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.911-915
    • /
    • 2014
  • Pyrotechnic devices are widely used for space appendages. However, a cube satellite requirements do not permit the use of explosive pyrotechnic device. A nichrome burn wire release has typically been used for holding and release of deployable appendages of the cube satellite due to its simplicity and low cost. However, relatively low mechanical constraint force and system complexity for application of multi-deployable systems are disadvantages of the conventional mechanism. To overcome these drawbacks, we have developed a segmented nut type holding and release mechanism based on the nichrome burn wire release. The great advantages of the mechanism are much lower shock level and larger constraint force than the conventional mechanism using pyro. Flight model for on-orbit verification was developed and verified through release function test, vibration test and thermal vacuum test.

  • PDF

Comparison of NOx Reduction Characteristics of NOx Storage Catalyst and TWC for Lean-burn Natural Gas Vehicles (희박 천연가스 자동차용 NOx 흡장촉매와 TWC의 NOx 반응특성 비교)

  • 최병철;정우남;이춘희
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.79-84
    • /
    • 2004
  • We evaluated the reduction performance of NOx storage catalyst and TWC for lean-burn natural gas engine by the model gas. The method of unsteady state reaction was used to compare with reduction performances of NOx storage catalyst and TWC. It was found that the effective parameter was rich spike duration, temperature of the model gas. In the presence of $CO_2$ and $H_2O$ in the reaction mixture was decreased the NOx reduction performance.

In-Cylinder Flow Analysis of a Lean-Burn Engine(I) (희박 엔진 연소실내의 유동해석(I))

  • Yang, H.C.;Lee, J.S.;Yoo, J.Y.;Choi, H.C.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.188-198
    • /
    • 1995
  • Turbulent flow characteristics of a lean-burn engine were qualitatively studied in order to obtain the optimum design parameters. 3-D lean-burn model engine was made up of an intake port, an intake valve and a cylinder. Computational grids were generated using PATRAN which was a FEM grid-generation software and numerical calculations were performed using STAR-CD. The predicted results showed that swirl and tumble structures were significantly changed by the valve lifts.

  • PDF

A Study on Turbulent Flame Propagation Model of S. I. Engines (스파크 점화기관의 난류 화염전파모델에 관한 연구)

  • 유욱재;최인용;전광민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2787-2796
    • /
    • 1994
  • The modeling of combustion process is an important part in an engine simulation program. In this study, calculated results using a conventional B-K model and the other model which is called GESIM were compared with experimentally measured data of a three-cylinder spark-ignition engine under wide range of operating conditions. The burn rates calculated from the combustion models were compared with the burn rate calculated from the one-zone heat release analysis that uses measured pressure data as an input data. As a result of the two models' comparison, the GESIM combustion model conformed to be closer to the data acquired from the experiment in wide operating ranges. The GESIM model has been improved by introducing a variable that considers the flame size, the area of flame conacting the piston surface into the model, based on the comparison between the experimental result and the calculated results. The improved combustion model predicts experimental results more precisely than that of GESIM combustion model.

Corrosive Stricture Model Induced-Esophageal Burn : Animal Pilot Data (NaOH 용액을 이용한 부식성 식도 협착 동물모델 형성에 관한 연구)

  • Kim, Min-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.643-647
    • /
    • 2021
  • The purpose of this study was to access the possibility and ideal model for corrosive-induced tissue hyperplasia in the rat esophagus. Twenty rat were divided into two group: a healthy group, corrosive group. corrosive burn in esophagus were produced using 30% NaOH on the distal esophagus. After surgical procedure, behavioral and weight changes were monitored on a weekly. At 3 weeks after surgical procedure, fluoroscopic esophagogram was performed and then all rats sacrificed for histological analysis by administering inhalable pure carbon dioxide. Technical surgery for corrosive stricture were 100%. A total of 2 rats died in corrosive group from a corrosive burn related to dysphagia within 14 days. The esophageal stenosis ratio was significantly higher in the corrosive group than in the healthy group (40.1 ± 9.2 % and 1.4 ± 7.2%, respectively; p = 0.001). The tissue hyperplasia ratio was also significantly higher in the Corrosive group (62.5 ± 9% and 22.08 ± 6%, respectively; p = 0.001). Infusion of 30% NaOH may suggest alternative option to evaluation tool for preclinical study in a rat corrosive model.

Studies on the Wound Healing by the PVA-soft hydrogel (화상 및 창상 치료용 외용제제 개발에 대한 기초 연구)

  • 조동현;신영희
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.55-59
    • /
    • 2004
  • A PVA-soft hydrogel, which is a semi-solid form in container, whereas after applying on the skin, it formed a thin layer within a few minutes. In this study, we prepared a novel type PVA-soft hydrogel containing 6-methyluracil as active drug, and the therapeutic value was characterized. To evaluate the therapeutic value of the PVA-soft hydrogel containing drug, various animal models, thermal burn model, incision & excision wound rat model were used. We also measured the wound size and breaking strength to calculate the wound healing extent after single or multiple administration. The wound size of soft hydrogel treated group decreased rapidly than that of control group after multiple dosing in excision wound model. And, the breaking strength of the soft hydrogel treated group was greater than that of control group in incision wound model.

Creation of Consistent Burn Wounds: A Rat Model

  • Cai, Elijah Zhengyang;Ang, Chuan Han;Raju, Ashvin;Tan, Kong Bing;Hing, Eileen Chor Hoong;Loo, Yihua;Wong, Yong Chiat;Lee, Hanjing;Lim, Jane;Moochhala, Shabbir M.;Hauser, Charlotte A.E.;Lim, Thiam Chye
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.317-324
    • /
    • 2014
  • Background Burn infliction techniques are poorly described in rat models. An accurate study can only be achieved with wounds that are uniform in size and depth. We describe a simple reproducible method for creating consistent burn wounds in rats. Methods Ten male Sprague-Dawley rats were anesthetized and dorsum shaved. A 100 g cylindrical stainless-steel rod (1 cm diameter) was heated to $100^{\circ}C$ in boiling water. Temperature was monitored using a thermocouple. We performed two consecutive toe-pinch tests on different limbs to assess the depth of sedation. Burn infliction was limited to the loin. The skin was pulled upwards, away from the underlying viscera, creating a flat surface. The rod rested on its own weight for 5, 10, and 20 seconds at three different sites on each rat. Wounds were evaluated for size, morphology and depth. Results Average wound size was $0.9957cm^2$ (standard deviation [SD] 0.1845) (n=30). Wounds created with duration of 5 seconds were pale, with an indistinct margin of erythema. Wounds of 10 and 20 seconds were well-defined, uniformly brown with a rim of erythema. Average depths of tissue damage were 1.30 mm (SD 0.424), 2.35 mm (SD 0.071), and 2.60 mm (SD 0.283) for duration of 5, 10, 20 seconds respectively. Burn duration of 5 seconds resulted in full-thickness damage. Burn duration of 10 seconds and 20 seconds resulted in full-thickness damage, involving subjacent skeletal muscle. Conclusions This is a simple reproducible method for creating burn wounds consistent in size and depth in a rat burn model.

Therapeutic Effects of Acupuncture and Herbal External Preparation on Healing of Deep Partial Thickness Burn Wound in Rats (심재성 2도 화상이 유발된 흰쥐의 조직 회복에 대한 침 및 한약외용제의 효과)

  • Jo, Hee-Guen;Park, Ae-Ryon;Choi, Jin-Bong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.3
    • /
    • pp.87-98
    • /
    • 2014
  • Objectives The present study aimed to investigate the effects of acupuncture and herbal external preparation on wound healing procedure in a deep partial thickness burn model in rats. Methods A total of 40 male Sprague-Dawley rats were allocated into four groups with an equal number in each group: acupuncture treatment group, herbal external perparation group, Silver sulfadiazine dressing group and control group. We describe the effect of acupuncture and herbal external preparation on morphologic and histologic changes, epithelial growth factor (EGF), hematological value of the deep partial thickness burn wound in rats. Results At 21th day after wounding the wound size in acupuncture treat group and herbal external preparation group were decreased more significantly compared to control group. In addition, epidermal regeneration on acupuncture treatment was than other treatment and control group in histological finding. Hematological findings revealed that acupuncture treatment group and herbal external prepartion group was more effective than control group in reducing inflammation response induced by burn. In acupuncture treated group, neutrophil and leukocyte level were significantly decreased compared to other treatment group. Also, this study showed that EGF was obviously expressed in nascent tissue when wounds were treated with the acupuncture and herbal external preparation after injury. In particular, acupuncture treatment group had a significant increase of EGF expression in burn wound healing area when compared with the other treatment groups. Conclusions These findings suggest that acupuncture and herbal external prepration may improve burn wound healing through decreasing inflammatory reaction, increasing tissue regeneration and expression of EGF. Moreover, acupuncture treatment could be more effective in comparison with Silver sulfadiazine dressing.

Launch and On-orbit Environment Verification Test of Flight Model of Hinge Driving Type Holding and Release Mechanism based on the Burn Wire Release (열선분리방식을 이용한 힌지구동형 구속분리장치 비행모델의 발사 및 궤도환경 검증시험)

  • Lee, Myeong-Jae;Lee, Yong-Keun;Kang, Suk-Joo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.3
    • /
    • pp.274-280
    • /
    • 2016
  • Hinge driving type holding and release mechanism based on the burn wire release for application of cubesat is main payload of STEP Cube Lab. (Cube Laboratory for Space Technology Experimental Project) to be launched at 2015. It has high constraint force, low shock level as well as surmounting drawbacks of conventional nichrome burn wire release method that has relatively low constraint force and system complexity for application of multi-deployable systems. In this paper, we have proposed a flight model of holding and release mechanism for the verification of the constraint force and deployment status signal acquisition. To validate the effectiveness of the flight model, launch and on-orbit environment verification test have been performed.