• 제목/요약/키워드: Bur

검색결과 360건 처리시간 0.025초

2급 와동 복합레진 인레이 충전 후 변연누출에 관한 연구 (A STUDY ON THE MARGINAL LEAKAGE OF CLASS II COMPOSITE RESIN INLAY)

  • 강현숙;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.191-205
    • /
    • 1992
  • The purpose of this study was to evaluate the microleakage of class II composite resin inlays and compare them with the conventional light-cured resin filling restorations. Class II cavities were prepared in 60 extracted human molars with which cervical margins were located below 1.0mm at the cemento-enamel junction using No. 701 tapered fissure carbide bur. All of the prepared cavities were restored as follows and divided into 6 groups. Group I and 2 were restored using direct filling technique and group 3,4,5 and 6 were restored using direct inlay technique that was cemented with dual-cured resin cements. group I: Cavities were restored with light-curing composite resin, Brilliant Lux. group 2. Cavities were restored with light-curing composite resin, Clearfil PhotoPosterior. group 3: Cavities were restored with Clearfil CR Inlay and heat treated at $125^{\circ}C$ for 7 minutes. group 4: Cavities were restored with same material as group 3 and heat treated at $100^{\circ}C$ for 15 minutes. group 5: Cavities were restored with Brilliant (Indirect esthetic system) and heat treated at $125^{\circ}C$ for 7 minutes. group 6: Cavities were restored with same material as group 5 and heat treated at $100^{\circ}C$ for 15 minutes. All specimens were polished with same method and thermocycled between $6^{\circ}C$ and $60^{\circ}C$, then immersed in a bath of 2.0% aqueous solution of basic fuchsin dye for 24 hours. Dyed specimens were sectioned longitudinally and dye penetration degree was read on a scale of 0 to 4 by Tani and Buonocore's method 45). The results were as follows: 1. Microleakage was observed rather at the cervical margins than at the occlusal margins in all groups. 2. Composite resin inlay groups showed significantly less leakage than direct filling groups at the cervical margins (p < 0.001). 3. In composite resin inlay groups, there was no significant difference in microleakage between specimens by heat treating temperature and time (p > 0.05). 4. There was no significant difference in leakage between each groups at the occlusal margins (p > 0.05).

  • PDF

수종 근관확대 기구의 만곡된 치근관 성형능력 (SHAPING ABILITY OF ROOT CANAL INSTRUMENTS ON CURVED ROOT CANALS)

  • 김명수;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.141-152
    • /
    • 1992
  • Four endodontic instruments from different manufacturers(K - file, Hedstrom - file, K - flex - file, Cavi - Endo) were used to shape 80 mesial canals of extracted posterior teeth. The instrument's ability to enlarge and shape the canals as the original canal shape was assessed by superimposing radiographs of canals obtained before and after canal shaping. The results were as follows 1. Hedstrom - file enlarged canals greater than K - file, K - flex - file, and Cavi - Endo(P<0.05). There are no differences in canal enlargement among K - flex, K - flex - file, and Cavi - Endo(P<0.05). 2. All the instruments showed no difference in canal enlargement between convex side and concave side of B point in proximal and clinical radiographic views, but at the concave side of C point canals were enlarged greater than at the convex side(proximal view of K - file: P<0.05, the others: P<0.01). 3. There was no difference m canal enlargement between convex side and concave side in proximal view of A and D points of K - file and K - flex - file(P<0.05). But in clinical view, canal enlargement at convex side of A point and concave side of D point was greater than that at concave side of A point and convex side of D point respectively. 4. Hedstrom - files showed greater canal enlargement at convex side of A points and concave side of D points (P<0.05 or P<0.01). Cavi - Endo showed no difference in canal enlargement between convex side and concave side at A and D points in proximal view(P<0.05). Bur canal enlargement was greater at concave side than at convex side of D point in clinical view. 5. K - file and Cavi - Endo showed no differences in canal enlargement between convex and concave side in proximal and clinical view (P<0.05). K - flex - file showed greater canal enlargement at concave side in proximal and clinical view(P<0.0:5). Hedstrom file showed no difference in canal enlargement between convex side and concave side in proximal view, but showed greater canal enlargement at concave side in clinical view(P<0.05).

  • PDF

Orthodontic bracket bonding to glazed full-contour zirconia

  • Kwak, Ji-Young;Jung, Hyo-Kyung;Choi, Il-Kyung;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.106-113
    • /
    • 2016
  • Objectives: This study evaluated the effects of different surface conditioning methods on the bond strength of orthodontic brackets to glazed full-zirconia surfaces. Materials and Methods: Glazed zirconia (except for the control, Zirkonzahn Prettau) disc surfaces were pre-treated: PO (control), polishing; BR, bur roughening; PP, cleaning with a prophy cup and pumice; HF, hydrofluoric acid etching; AA, air abrasion with aluminum oxide; CJ, CoJet-Sand. The surfaces were examined using profilometry, scanning electron microscopy, and electron dispersive spectroscopy. A zirconia primer (Z-Prime Plus, Z) or a silane primer (Monobond-S, S) was then applied to the surfaces, yielding 7 groups (PO-Z, BR-Z, PP-S, HF-S, AA-S, AA-Z, and CJ-S). Metal bracket-bonded specimens were stored in water for 24 hr at $37^{\circ}C$, and thermocycled for 1,000 cycles. Their bond strengths were measured using the wire loop method (n = 10). Results: Except for BR, the surface pre-treatments failed to expose the zirconia substructure. A significant difference in bond strengths was found between AA-Z ($4.60{\pm}1.08MPa$) and all other groups ($13.38{\pm}2.57-15.78{\pm}2.39MPa$, p < 0.05). For AA-Z, most of the adhesive remained on the bracket. Conclusions: For bracket bonding to glazed zirconia, a simple application of silane to the cleaned surface is recommended. A zirconia primer should be used only when the zirconia substructure is definitely exposed.

광중합형 글래스 아이오노머 시멘트의 치질접착에 관한 연구 (THE ADAPTATION OF LIGHT CURED GLASS IONOMER CEMENTS TO TOOTH STRUCTURE)

  • 허승면;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.489-504
    • /
    • 1996
  • The purpose of this study was to compare the adaptation to the tooth structure of five light cured glass ionomer cements (Fuji II LC. VariGlass VLC, Vitremer, Dyract and Geristore). Human, non-carious fifty extracted permanent premolars stored in normal saline were used. Class V cavity preparations were created on the buccal surfaces. The occlusal margin of each cavity was placed on the enamel and the gingival margin was placed on the cementum/dentin. The teeth were then distributed at random into five groups of 10 teeth each. Group 1: Fuji II LC, Group 2 : VariGlass VLC, Group 3 : Vitremer, Group 4: Dyract, Group 5 : Geristore. The prepared cavities were restored with one of the five light cured glass ionomer cements. The manipulation of each material was handled according to the manufacturer's instructions. All samples were placed in incubator of 100% relative humidity at $37^{\circ}C$ for 24 hours. The roots of the teeth were removed with the tapered fissure bur and the remaining crowns were sectioned buccolingually through the center of restorations. The cut interfaces were gradually hand polished on sandpapers from 300 up to 1200 grit. The adaptation at the tooth/cements interface was assessed by SEM (JSM-840A, JEOL Ltd.). The results of this study were as follows : 1. Group 2 revealed the best adaptation and groups 1, 4 and 5 revealed similar adaptation pattern to the cavity walls. Group 3 revealed the worst adaptation to the cavity walls. 2. Enamel margins showed better adaptation than dentin/cementum margins with each material except group 3. 3. The hybrid layers were observed between the glass ionomer cement and dentin in groups 2, 4 and 5.

  • PDF

지식의 융합과 경계적 사유 (Convergence of Knowledge and Border Thinking)

  • 박만준
    • 철학연구
    • /
    • 제116권
    • /
    • pp.111-132
    • /
    • 2010
  • 최근 지식의 융합에 관한 논의가 많이 이루어지고 있음에도 불구하고 왜 지식의 융합인가 혹은 지식의 융합이 어떻게 가능한가에 대한 논의는 그리 많지 않다. 이 글은 이를 논의하기 위해 '우리의 지식은 무엇을 위해 존재하는가?'라는 물음에서 출발한다. 지식의 존재 근거가 우리의 생존에 있다는 사실을 전제하기 위해서였다. 지식의 융합을 논하는 이유도 같은 맥락이다. 지식의 융합은 지식의 증가이며, 생존에 관한 올바른 지식이 증가할수록 생존의 위기와 위험은 그만큼 줄어들 것이기 때문이다. 지식의 융합은 단순한 지식의 확장이 아니라 생존과 직결되어 있다. 문제는 방법이다. 어떻게 지식의 융합이 가능한가? 가장 쉽게 생각할 수 있는 것이 경계적 사유와 경계 넘기이다. 경계적 사유는 단순히 두 영역 '사이'나 '중간'에 위치하는 것이 아니다. 두 영역을 함께 보는 것이 곧 경계적 사유이다. 그러므로 경계적 사유는 사유의 영역과 지식의 확장이다. 경계적 사유 자체가 사유의 새로운 영역이며 또 이를 통해 기존의 지식과는 다른 새로운 지식이 생산되기 때문이다. 그렇다면 과연 경계는 어디인가? 경계는 곧 마음이다. 그리고 지식의 생산과 융합은 마음의 프로그램이다. 결국 왜 융합인가에 대한 해답은 지식의 존재 근거와 동일하며, 둘 다 생존을 위한 우리 마음의 프로그램이다.

The push-out bond strength of BIOfactor mineral trioxide aggregate, a novel root repair material

  • Akbulut, Makbule Bilge;Bozkurt, Durmus Alperen;Terlemez, Arslan;Akman, Melek
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.5.1-5.9
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to evaluate the push-out bond strength of a novel calcium silicate-based root repair material-BIOfactor MTA to root canal dentin in comparison with white MTA-Angelus (Angelus) and Biodentine (Septodont). Materials and Methods: The coronal parts of 12 central incisors were removed and the roots were embedded in acrylic resin blocks. Midroot dentin of each sample was horizontally sectioned into 1.1 mm slices and 3 slices were obtained from each root. Three canal-like standardized holes having 1 mm in diameter were created parallel to the root canal on each dentin slice with a diamond bur. The holes were filled with MTA-Angelus, Biodentine, or BIOfactor MTA. Wet gauze was placed over the specimens and samples were stored in an incubator at $37^{\circ}C$ for 7 days to allow complete setting. Then samples were subjected to the push-out test method using a universal test machine with the loading speed of 1 mm/min. Data was statistically analyzed using Friedman test and post hoc Wilcoxon signed rank test with Bonferroni correction. Results: There were no significant differences among the push-out bond strength values of MTA-Angelus, Biodentine, and BIOfactor MTA (p > 0.017). Most of the specimens exhibited cohesive failure in all groups, with the highest rate found in Biodentine group. Conclusions: Based on the results of this study, MTA-Angelus, Biodentine, and BIOfactor MTA showed similar resistances to the push-out testing.

Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparation

  • Farah, Ra'fat I.
    • Restorative Dentistry and Endodontics
    • /
    • 제44권1호
    • /
    • pp.3.1-3.10
    • /
    • 2019
  • Objectives: It was the aim of this study to evaluate the effect of cooling water temperature on the temperature changes in the pulp chamber and at the handpiece head during high-speed tooth preparation using an electric handpiece. Materials and Methods: Twenty-eight intact human molars received a standardized occlusal preparation for 60 seconds using a diamond bur in an electric handpiece, and one of four treatments were applied that varied in the temperature of cooling water applied (control, with no cooling water, $10^{\circ}C$, $23^{\circ}C$, and $35^{\circ}C$). The temperature changes in the pulp chamber and at the handpiece head were recorded using K-type thermocouples connected to a digital thermometer. Results: The average temperature changes within the pulp chamber and at the handpiece head during preparation increased substantially when no cooling water was applied ($6.8^{\circ}C$ and $11.0^{\circ}C$, respectively), but decreased significantly when cooling water was added. The most substantial drop in temperature occurred with $10^{\circ}C$ water ($-16.3^{\circ}C$ and $-10.2^{\circ}C$), but reductions were also seen at $23^{\circ}C$ ($-8.6^{\circ}C$ and $-4.9^{\circ}C$). With $35^{\circ}C$ cooling water, temperatures increased slightly, but still remained lower than the no cooling water group ($1.6^{\circ}C$ and $6.7^{\circ}C$). Conclusions: The temperature changes in the pulp chamber and at the handpiece head were above harmful thresholds when tooth preparation was performed without cooling water. However, cooling water of all temperatures prevented harmful critical temperature changes even though water at $35^{\circ}C$ raised temperatures slightly above baseline.

In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium

  • Suzuki, Ginga;Shimizu, Satoshi;Torii, Mana;Tokue, Ai;Ying, Guo;Yoshinari, Masao;Hoshi, Noriyuki;Kimoto, Katsuhiko;Miura, Hiromi;Hayakawa, Tohru;Ohkubo, Chikahiro
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.369-375
    • /
    • 2020
  • PURPOSE. This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure. MATERIALS AND METHODS. The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test. RESULTS. Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/rpm in machinability tests (P<.05). CONCLUSION. Although the wear resistance and plaque adherence of MDF-Ti were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.

Comparative effects of systemic administration of levofloxacin and cephalexin on fracture healing in rats

  • Golestani, Shayan;Golestaneh, Arash;Gohari, Atousa Aminzadeh
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권2호
    • /
    • pp.94-100
    • /
    • 2022
  • Objectives: This study aimed to compare the effects of systemic administration of levofloxacin or cephalexin on fracture healing in rats. Materials and Methods: In this animal study, tibial fractures not requiring fixation were artificially induced in 30 male Wistar albino rats using a 1.1 mm surgical bur. The rats were randomly divided into 6 groups (n=5). Groups 1 and 2 received daily subcutaneous saline injections. Groups 3 and 4 received subcutaneous injections of 25 mg/kg levofloxacin twice daily. Groups 5 and 6 received daily subcutaneous injections of 20 mg/kg cephalexin. The rats in Groups 1, 3, and 5 were sacrificed after 1 week, while the rats in Groups 2, 4, and 6 were sacrificed after 4 weeks. The score of fracture healing was determined through histological assessment of sections from the fracture site according to Perry and colleagues. Data were analyzed by Kruskal-Wallis and Mann-Whitney tests. Results: The mean score of fracture healing at 4 weeks was significantly higher than that at 1 week in the saline, levofloxacin, and cephalexin groups (P<0.001). At 1 week, no significant difference was noted among the three groups of saline, levofloxacin, and cephalexin in the mean score of fracture healing (P=0.360). However, this difference was significant at 4 weeks (P=0.018), and the mean score in the saline group was significantly higher compared to that in the levofloxacin group (P=0.015). Conclusion: It is recommended not to prescribe levofloxacin for more than 1 week after surgical management of bone fractures due to its possible adverse effects on fracture healing.

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권1호
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.