Production of Compost Using Organic wastes

  • Lee, Jang-Hoon;Jung, Joon-Oh;Kwon, Hyuk-Ku;Nam, Youn-Ku;Yun, Jung-Won
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.406-409
    • /
    • 2005
  • Since 2003, Korean government has restricted landfill application of organic waste, which shares approximately 56% of total waste sludge from municipal and industrial wastewater treatment plants. In addition, enforcement of the ocean disposal prohibition law is effective from 2005. Organic sludge was composted for the purpose of converting to organic fertilizer. After moisture content was regulated with bulking agents aerobic treatment performed. When composting was conducted, commercial and activated microbe materials, identified from soil were seeded in sewage sludge. Carbon dioxide production was increased sharply after 24 hours. Temperature and pH of compost reached to $66.2^{\circ}C$ and 8. Heavy metals were lower than their regulatory limits, which enable it to utilize as organic fertilizer.

  • PDF

A Study on the COD Removal in the Paste-board Wastewater by Activated Sludge Process (활성오니법에 의한 판지폐수중의 COD 제거에 관한 연구)

  • 도갑수;김영운
    • Journal of the Korean Professional Engineers Association
    • /
    • v.18 no.3
    • /
    • pp.28-35
    • /
    • 1985
  • As the paper industry consumes much water in process and discharge wastewater containing suspended solid and COD(chemical oxygen demand), relevant law against this discharge has been set up to limit the total containment of COD in discharge. This study has been carried out to improve the treatment method for the soluble COD in wastewater produced during the process of paste-board production, which is made of semichemical pulp and waste paper. Applicated methods are, O$_2$AS : O$_2$ activated sludge process DAS : Deep well activated sludge process SAS : standard activated sludge process and proper combination of DAS and SAS 1) As a result of this experiment, we get the following conclusion between in COD sludge loading "X" and COD removable rate in the process of treating waste-water. COD removable rate(%)=(0.778+0.0146/X)${\times}$100(%)……(7) 2) In case that the COD sludge loading is high, it has been cleared out that the COD removable rate shall become low due to unknown unsoluble substances contained in the process. Meanwhile, to increase the efficiency rate of treatment, it is thought to be necessary, to provide long-time contacts with activated sludge. 3) Once the COD of original waste-water and the target COD of treated water are decided, COD sludge loading is obtained from equation(7), and capacity of aeration tank in the effective systems such as O$_2$AS, DAS, to bet the required COD removable rate can be decided. Therefore the choice among SAS, O$_2$AS, DAS methods is made in consideration of required COD removable rate and allowable installation area. 4) In the sedimentation tank with sludge bulking, it is possible to increase the COD removable rate by 3~7% but still there exist many obstacles to manage this operation.

  • PDF

A Study on the Municipal Wastewater Treatment Using Biofilm Process (생물막공법을 이용한 도시하수처리에 관한 연구)

  • Kwak, Byung Chan;Tak, Seong Jae;Kim, Nam Cheon;HWang, Yong Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.62-75
    • /
    • 2000
  • Most of biological treatment to remove contaminants in municipal wastewater have been conducted by activated sludge process. But, the process have several probIems such as enormous site needed for construction of treatment facilities, unstable treatment due to limited ability to control load fluctuation, frequent sludge bulking and appearance of lots of surplus sludge. In this study, the experiments were performed through submerging biofilm of PEPP media in existing aeration tank with raw water from municipal wastewater treatment plant and then submerging PVDC and PEPP media, different from shape and chemical peculiarity in anoxic reactor. Throughout the experience, nutrient removal efficiency according to HRT, nitrogen phosphorous removal efficiency, behavior of nitrogen and dewatering efficiency have been compared and analysed with those of activated sludge process. As the results, BOD removal efficiency according to BOD volumetric load and F/M ratio was not found any differency in two processes, but was decreased below 90% as going along the condition of high load in activated sludge process. Kinetic coefficient was $K_{max}=1.162day^{-1}$, $K_s=53.77mg/L$, $Y=0.166mgVSS/mgBOD_{rem}$. and $K_d=0.019day^{-1}$. It was found that the removal efficiency, even though in aerobic condition, in biofilm process equipped anoxic reactor was higher than the one in activated sludge process within the range of 70~80%, and became better as HRT increased. Phosphorous removal efficiency was not found any differency in two processes. In biofilm process, treament efficiency even in conditions of high load was not decreased, because the biomass concentration could be maintained in high condition compared with activated sludge process. As HRT increased, suspended and attached biomass was increased and the other hand, F/M ratio was decreased as biomass' increasing. Biomass thickness was increased. from $10.43{\mu}m$ to $10.55{\mu}m$ as HRT increased and density of biomass within $40.79{\sim}41.16mg/cm^2$. The results also present that the dewatering efficiency of sludge generated in biofilm process was higher than in activated sludge process, and became better as HRT increased.

  • PDF

Development of Operating Parameters for Composting of Municipal Sewage Sludge (도시 생활하수 슬러지의 퇴비화를 위한 부숙공정지표 설정)

  • Lee, Hong-Jae;Cho, Ju-Sik;Choi, Hyoung-Sub;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.382-389
    • /
    • 1997
  • To study the optimum conditions of composing with sewage sludge, the variations of temperature and $CO_2$ generation amount during composting periods were investigated. The conditions were that sewage sludge added to bulking agents such as sawdust and rice hull were used and differently treated with microorganism seeding or not, initial C/N ratio, air flow rate and initial moisture contents. The results were summarized as follows : Seeding of 5% microorganism was higher temperature than not seeding. And using rice hull as bulking agents, and adjusting 21${\sim}$22 of initial C/N ratio, $200ml/l\;{\cdot}\;min$. of air flow rate and 64${\sim}$65% of initial moisture contents were higher temperature than any other conditions. Seeding of 5% microorganism was more $CO_2$ generation amount than not seeding. And using saw dust was more $CO_2$ generation amount than using rice hull as bulking agents. In the case of initial C/N ratio, adjusting 21${\sim}$42 was also more $CO_2$ generation amount than adjusting 12${\sim}$14. Judging from the result, it should be considered that the optimum conditions of composting with sewage sludges were seeding of 5% microorganism and adjusting 21${\sim}$22 of initial C/N ratio, $200ml/l\;{\cdot}\;min$. of air flow rate and 64${\sim}$65% of initial moisture contents.

  • PDF

Characteristics and Control of Microthrix Parvicella Bulking in Biological Nutrient Removal Plant (생물학적 영양소제거공정에서 Microthrix Parvicella에 의한 Bulking 특성 및 제어)

  • Lee, H.;Ahn, K.
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1101-1106
    • /
    • 2006
  • Many BNR (Biological Nutrient Removal) plants have experienced a bulking problem, mainly due to the growth of filamentous organisms, particularly during the winter months. This study investigated the problem of bulking due to the growth of M. parvicella both at a full-scale municipal wastewater treatment plant and a pilot scale plant located in the C city. The full-scale facility was operated at a flow rate of $51,000m^3/d$, an F/M (Food-to-Microorganism) ratio of 0.12 kgBOD/kgMLVSS/d and an SRT (Solids Retention Time) higher than 25 days, respectively. This plant experienced bulking and foaming problems at low temperatures below $15^{\circ}C$ since it was retrofitted with the BNR system in 2003. The pilot plant employed had an identical process configuration as the full scale one and used the same wastewater source. It was operated at a flow rate of $3.8m^3/d$, temperatures between 10 to $25^{\circ}C$ and SRTs between 10 and 25 days. At full scale, the M. parvicella growth and SVI (Sludge Volume Index) patterns were studied in conjunction with temperature variations. At pilot scale, DO and SRT variations were also explored, in addition to the filamentous bacteria growth and SVI patterns. During the full-scale investigation, over a 3 year period, it was noted that the SVI was maintained within acceptable operational values (i.e. under 160) during the summer months. Moreover settling in the secondary clarifiers was good and was not affected by the presence of M. parvicella. In contrast, at low mean temperatures during winter, the SVI increased to over 300. Overall, as the temperature decreased, the predominance of M. parvicella became apparent. According to this study, M. parvicella growth could be controlled and SVI could drop under 160 by a change in operational conditions which involved an increase in DO concentration between 2 and 4 mg/L and a decrease in SRT to less than 20 days.

A Study on the Operation Aid Expert System for Activated Sludge Process (활성슬러지 공정에서의 조업지원용 전문가 시스템에 관한 연구)

  • Cho, Wook-Sang;Lee, Jin-Woo;Park, Sang-Jin;Won, Jong-Sik;Kim, Sang-Wook
    • Applied Chemistry for Engineering
    • /
    • v.7 no.2
    • /
    • pp.371-378
    • /
    • 1996
  • A prototype of expert system which can support the operation for the municipal waste water treatment plant located at Kyoung-Ki Do, Kwang-ju Kun was developed and tested. This system provides (i) tracking the cause of the problem, (ii) analysis, and (iii) solution Knowledge-base consists of about 100 production-rules for the biological wastewater process, such as bio-reactor and final clarifier. Rules were obtained from the analysis of the problems such as sludge bulking. The system provides stable process control and management and effectively helps inexperienced operators with advanced and standard technologies. Future works will focus to develop a statistical process control model and associate with expert system. The control model can process the operation data statistically; analyze the relationship between affecting factors and control variables; and provide optimum operation parameters.

  • PDF

A Study on the Separation of Activated Sludge by Dissolved Air Flotation (가압부상법(加壓浮上法)에 의한 활성(活性)슬러지 혼합액(混合液)의 고액분리(固液分離)에 관한 연구(研究))

  • Yang, Sang Hyun;Ra, Deog Gwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.21-29
    • /
    • 1985
  • An effective technique of sludge separation is required for concentrated activated sludge process. The dissolved-air flotation (DAF) has been shown to be efficient process for sludge separation. The factors affecting DAF process for activated sludge separation are type and concentration of sludge, air/solid ratio, ratio of pressurized water flow, pressure, sludge detention time, temperature, sludge and hydraulic loading rate, recycle flow rate of sludge and type and quantity of chemical aid. In order to study the optimal operation condition for sludge separation, the influence factors such as type and concentration of sludge, ratio of pressurized water flow and pressure are investigated by the batch and continuous reactor experiments of DAF and sedimentation test. By the experimental investigation, the results are as follows; 1. For the bulking and concentrated sludge, DAF is more effective than sedimentation for the sludge separation. 2. In DAF, the critical ratio of pressurized water flow exist. The critical value varies with the pressure in the tank. That is, according to the pressure changes from 3 to $5kg/cm^2$, the critical value varies from 0.25 to 0.67 accordingly. 3. Pressure affects the ratio of pressurized water flow, but it does not show any influence upon the DAF efficiency directly. 4. Continuous experimental results was not better than those of batch.

  • PDF

Changes in several physco-chemical properties of aged food waste and feeding response of tiger worms(Eisenia fetida) on it (부숙된 음식물 쓰레기의 이화학성상 변화 및 줄지렁이의 섭식반응)

  • Bae, Yoon-Hwan;Lee, Byung-Do
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.4
    • /
    • pp.130-138
    • /
    • 2004
  • Food wastes with different regional origins were mixed with bulking agent such as paper mill sludge or night soil, and aged for 21 days or 28 days. And aged food wastes were fed to the earthworm(tiger worm, Eisenia fetida) for 60 days. There were no significant physico-chemical differences among the food wastes with different regional origins. EC values and NaCl concentrations in food wastes were too high for earthworms to survive. Food wastes mixed with paper mill sludge were vermicomposted more efficiently than food wastes mixed with night soil, but the over-all vermicomposting rates on the food wastes were much lower than that on paper mill sludge because EC values and NaCl concentrations were still high for earthworm to compost the feeds. Earthworm population did not increase its biomass on the food wastes mixed with paper mill sludge or night soil, whereas earthworm population fed with paper mill sludge increased its biomass by 20% for 60 days. It could be concluded that a solution for reducing NaCl concentrations in food waste should be developed to vermicompost food waste.

  • PDF

Application of Electron Beam for Accelerating Composting of Sewage Sludge (하수슬러지 퇴비화촉진을 위한 전자빔의 응용)

  • Kang, Ho;Shin, Kyung-Sook;Jeong, Ji-Hyun;Schuchardt, Frank
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.2
    • /
    • pp.62-70
    • /
    • 2010
  • A feasibility test for accelerating composting of sewage sludge irradiated with electron beam(3kGy) was investigated. Dried wood chip and leaves were used as a bulking agent and carbon source, respectively. The test variables included changes in temperature, organics and nutrients, and bioactivities from experimental and control composters. Results indicates that the temperature rose up to $60^{\circ}C$ within 1 day and maintained high temperature above $50^{\circ}C$ for more than 5 days in the irradiated sludge cake composter. It resulted in the fast degradation of organics during the initial 5 days, showing that approximately 70% of total amount of carbon degraded within 20 days was destroyed. It is likely that the composting of electron beam irradiated sludge cake is able to reduce it's maturing period significantly.

Effects of Sewage Treatment on Characteristics of Sludge as a Composting Material (하수처리가 퇴비화를 위한 하수 슬러지 특성에 미치는 영향)

  • Kim, Jae-Koo;Kim, Jong-Soo
    • Applied Biological Chemistry
    • /
    • v.41 no.2
    • /
    • pp.181-186
    • /
    • 1998
  • The effects of sewage treatment on characteristics of sludge as a composting material were investigated for a year during the initial operation at the full-scale Chunan sewage treatment plant. Due to the shortage of design capacity of belt press, a sludge dewatering unit, non-volatile solids were recirculating and concentrating in the treatment plant, resulting in an increase of MLSS and a decrease in F/M ratio at the activated sludge system. Special attention is required for long term operations since the increase of non-volatile solids in the plant would deteriorates the treatment efficiency. The sewage sludge of the Chunan sewage treatment plant showed 79.5% of water content, 11.6% of organic content, and C/N ratio of 6.1, and contained As 1.8 mg/kg, Cd 27 mg/kg, Hg <0.1 mg/kg, Pb 54 mg/kg, T-Cr 370 mg/kg, and Cu 1,100mg/kg of heavy metals. In order to be used as raw material for optimum composting, the sewage sludge requires bulking agents for moistrure/porosity control and a carbon source for adjusting C/N ratio. However, the sewage sludge is not adequate as a soil conditioner after composing due to a high content of heavy metals. If the sewage sludge has to he used as a soil conditioner after composting, it as required to identify and remove tire industrial wastewater portions in tire influent of the plant since heavy metals in the influent were mostly concentrated in dewatered sludge.