• Title/Summary/Keyword: Built-up

Search Result 1,827, Processing Time 0.027 seconds

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.10 no.3
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

Study on Change in Landscape Structure over Time in Suburban Area by Using GIS -Case Study of Kawachinagano City, Osaka-

  • Kaga, Horoyuki;Izaki, Noriaki;Shimomura, Yasuhiko;Masuda, Noboru
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.1
    • /
    • pp.67-74
    • /
    • 2001
  • Now that importance of landscape planning unique to each area is emphasized, it is necessary to conduct landscape planning by taking advantage of natural environments unique to each ares, because its natural environments are regarded as one of the assets the area possesses. This study targets at Kawachinagano City, Osaka, one of the residential areas that I not only rich in natural and historical elements, but also has been rapidly growing. The purposes of this study are to evaluate change in landscape structure over time by analyzing relation between landform and pattern of expanding the built-up area at three time points of 1932, 1967, and 1994 with GIS (ARC/INFO 7.0.3, ARC/View 3.0 (ESRI)), as well as to make some suggestions for planning landscape unique to the area. Data on main ridges, sub ridges, main rivers, and other landform were read from the elevation map, and data on woodland, and parks and open spaces (having more than 3 ha area) were read from the existing land use map. The data were used to understand the natural structure of the city from topographic viewpoint. Next, the existing land use map prepared with data on the built-up area and urban axes consisting of roads and streets were overlaid on the elevation map in order to understand relation between pattern of expanding the built-up area and the natural structure.

  • PDF

A Study on the Minimum Production Cost of Welded Built-up Beams (용접 조립보의 최소 생산 비용에 관한 연구)

  • Chang-Doo Jang;Seung-Il Seo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.154-164
    • /
    • 1994
  • In this study, to find an economical production method which yields welded built-up beams with high quality, simulation techniques and optimization method are used. At first, fabrication variables such as welding current, voltage and speed and heated depth and breadth are selected and fabrication cost of a built-up beam is expressed by these parameters, which is optimized under the constraints. As advanced studies, total production cost including the fabrication cost and the material cost of the beam is expressed by the fabrication and design variables, and optimized with the design constraints by the class rules. In addition, assuming that heating for straightening is impossible. the optimization method of multi-objective functions based on the weighting method is applied to obtain the compromised optimal solutions of the total production cost and the welding deformation.

  • PDF

Structural behaviour of stainless steel stub column under axial compression: a FE study

  • Khate, Kevinguto;Patton, M. Longshithung;Marthong, Comingstarful
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1723-1740
    • /
    • 2018
  • This paper presents a Finite Element (FE) study on Lean Duplex Stainless Steel stub column with built-up sections subjected to pure axial compression with column web spacing varied at different position across the column flanges. The thicknesses of the steel sections were from 2 to 7 mm to encompass a range of section slenderness. The aim is to study and compare the strength and deformation capacities as well as the failure modes of the built-up stub columns. The FE results have been compared with the un-factored design strengths predicted through EN1993-1-4 (2006) + A1 (2015) and ASCE8-02 standards, Continuous Strength Method (CSM) and Direct Strength Method (DSM). The results showed that the design rules generally under predict the bearing capacities of the specimens. It's been observed that the CSM method offers improved mean resistance and reduced scatter for both classes of cross-sections (i.e. slender and stocky sections) compared to the EN1993-1-4 (2006) + A1 (2015) and ASCE 8-02 design rules which are known to be conservative for stocky cross-sections.

Stiffening schemes for CFS built-up I-beams with large global imperfections: Capacity and behaviour

  • Dar, M. Adil;Anbarasu M.;Dar, A.R.;Islam, Naqeeb Ul;Ghowsi, Ahmad Fayeq;Carvalho, Hermes
    • Steel and Composite Structures
    • /
    • v.42 no.4
    • /
    • pp.447-458
    • /
    • 2022
  • Cold-formed steel (CFS) sections are thin-walled, therefore, more susceptible to different types of geometric imperfections. Global type of geometric imperfections has a significant impact on the load-carrying capacity of flexural members. This paper reports an experimental study that discusses the influence of global imperfections on the flexural response of CFS built-up I-beams composed of two lipped channels, with simply supported ends, under four-point loading. Global imperfections of magnitude over eight times the maximum permissible ones were induced in the specimens, leading to their distress. Using various simple stiffening schemes, the capacity and stiffness of the distressed specimens were improvised. The performance comparisons were made based on the maximum loads resisted, flexural stiffnesses offered, and failure modes experienced by the specimens. As experimental data on such distressed specimens are currently lacking in the literature, the test results of the present study will provide the necessary data needed by future researchers to numerically extend this study further, which will help in the development of necessary design guidelines for the same. The stiffening schemes significantly improved the structural efficiency of distressed specimens in terms of strength and stiffness, by over 60%. As a result, an effective and time-saving solution to such realistic structural engineering problems is given.

Seismic response of built-up double-I column in steel moment resisting frame using welded external diaphragm plate

  • Tabebordbar, Amir;Dehghan, Seyed Mehdi;Fathi, Farshid;Najafgholipour, Mohammad Amir
    • Steel and Composite Structures
    • /
    • v.41 no.5
    • /
    • pp.747-759
    • /
    • 2021
  • Built-up Double-I (BD-I) columns have been commonly used for mid-rise steel-frame structures in Iran. These columns consist of two hot rolled IPE sections which are connected by two cover plates and fillet welds. Until 2017, BD-I columns were employed in intermediate moment resisting frames (MRF) using welded flange plate (WFP) connections. To evaluate the seismic behavior of the connections, four samples were made and tested based on cyclic loading according to AISC 341-16. It was concluded that typical samples cannot satisfy the seismic provisions related to intermediate MRFs. In contrast, the proposed connections retrofitted with two-part external diaphragms were able to satisfy not only the seismic requirements related to intermediate MRFs but also those related to special MRFs according to AISC. The numerical modeling of these samples was performed using ABAQUS finite element software. This study compared the hysteresis moment-rotation curves, plastic strains, and behavior modes in both experimental samples and numerical models.

A Study on the Development of Ship Building for the Wooden Canoe by Piling-up Laminated Wooden Plates Kit [1] - A Design for canoe hull and laminating wooden plates for piling-up kit - (적층식 평판 키트형 카누 건조 기술 개발에 관한 연구 [1] - 카누 선체의 설계 및 적층식 평판 키트 분할 기법 -)

  • Kim, Heui-Jung;Kim, Shung-Hyun;Jeong, Jae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.762-769
    • /
    • 2009
  • A canoe is one of the most popular boats in leisure on the water. Generally canoe has been built by good wooden strips. And canoe built by FRP is used for business recently. But by the users' demands for good quality and the restriction to environmental pollution the wooden canoes are required for personal and canoe building business. The modern wooden canoes were built by the strip construction method are used typically. However it is not suitable for the mass productivity requires effective resource operations and managements of men, materials, times, and price. On this paper the new construction method, called the piling-up laminated construction method, is studied to building a canoe using the piling-up with the laminated wooden plates gives more productivity than the others. First a canoe with various curved surfaces is designed from 3D design system. And the hull of canoe model is divided horizontally to generating the laminated plates that will be converting real wooden plates available from the market and will be routed by the manufacturing machine. After the simulating and analyzing of piling-up with the laminated plates, the canoe is building with less times, less men, less resources, and lower price than other method, avoid of the requirements of additional building tools. On the next paper the constructing of a real canoe using the manufactured wooden plates will be studied.

A Study on the Standardization of the Built-in Wardrobe by Housing Inside Dimension (공동주택 안목치수 설계기준에 의한 붙박이장의 표준화방안 연구)

  • Lee, Ga-Kyung;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.53-60
    • /
    • 2010
  • Built-in wardrobe is constructing after ordering and making, because built-in wardrobe's size is fixed as housing measurement. It is hard to speak built-in wardrobe components of construction in these ways, and application of an MC (Modular Coordination) design system is meaningless too. And above all, measurement before construction isn't to expect standardization, and to increase custom-made furniture. So I suggest the standardization of built-in wardrobe utilizing standard last finish and reference plane in order to prevent an evil influence of built-in wardrobe's construction. And we utilized a reference plane, and we present construction document and design plan in order to solve these problems. The first stage, we investigate manufacture of a preferential domestic system kitchen and construction state, and we derive from a problem in viewpoints of standardization for this. And we analyze an effect got by application of the assembly basis aspect that we presented, and we can raise efficiency of standardization of housing and construction industry, and we light ultimately up. I will apply a standardization plan as above, and define that this assures a standardization of components and an economic effect.

Strength Evaluation for Adhesive Bonds of Adhesive with FRP Ship Body Structure (FRP 선체구조용 접착제의 접착강도 평가)

  • Ahn, Seok-Hwan;Choi, Han-Kyu;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.146-152
    • /
    • 2010
  • Recently, the applied frequency of composite materials was increased from the viewpoint of lightweight, high strength and low cost when a leisure boat and a fishing boatwere built. However, studies on the mechanical properties of composite material with ship are rare. Specially, a leisure boat and fishing boat with FRP had been built by hand lay-up method. However, the vacuum infusion method is rising recently for ship building. The manufactured these FRP plates were combined by using the adhesive. Therefore, in this study Cleavage peel strength, Shear strength and fatigue limit of adhesive bonds by tensileloading were estimated. From test results, the strengths of FRP specimens made by the vacuum infusion method are higher than that of the hand lay-up method.

Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds (블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구)

  • Joe, Won-Hwa;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.2
    • /
    • pp.97-104
    • /
    • 2010
  • This study evaluated the energy efficiency of a windows system using built-in blinds, with regard to their insulation performance and their blocking of solar radiation. The study took advantage of the "Physibel Voltra" program as a physical simulation of heat transfer. To simulate the "Physibel Voltra" program, I practiced a mock-up test to determine heating quality and translation condition. I analyzed the propensity to annual energy consumption, the annual quantity of heat transfer, and the annual cooling and heating cost through a computer simulation for one general household in an apartment building. In the test, it was found that compared to a general windows system, a windows system with built-in blinds reduced the annual heat transfer by 10% in cooling states and by 11% in heating states when the blind was up. When the blind was down, the windows system with built-in blinds reduced the annual heat transfer by 25% in cooling states and 30% in heating states. When a windows system with built-in blinds is compared with a general windows system, the quantity of cooling and heating loads is reduced by 283.3kw in cooling states and 76.3kw in heating states. This leads to a reduction in the required cooling and heating energy of 359.6kw per house. It is thus judged that the use of a windows system with built-in blinds is advantageous in terms of reducing greenhouse gas emissions, because the annual TOE (tons of oil equivalent) per house is reduced by 0.078TOE, while $tCO_2$ is reduced by $0.16tCO_2$. In addition, compared with a general windows system, the cost of cooling and heating loads in the system reduces the annual cooling cost by 100,000won, and the annual heating cost by 50,000won. Ultimately, this means that cooling and heating loads are cut by 150,000won per year.