• 제목/요약/키워드: Building thermal performance

검색결과 636건 처리시간 0.023초

우리나라 영유아 보육시설의 친환경 실내를 위한 체크리스트와 디자인안 제안 (Checklist and Design Recommendations for the Interiors of Korean, Eco-healthy Childcare Facilities)

  • 천진희
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.105-114
    • /
    • 2010
  • As children are known to touch and chew everything, green cleaning procedures are an important step in preventing children from ingesting harmful toxins. The objectives of this study are to develop a new, self-evaluation checklist and to suggest design recommendations which comply with easy, adaptable, economical ways to improve the eco-friendly indoor environment of Korean childcare facilities. The information compiled during this study was collected through literature review and internet surveys1) from July, 2009 to February, 2010. The results of this study show that the current Korean childcare accreditation system and practices emphasize clean building interiors, policies for sanitation and cleanliness, and control of humidity and lighting. On the other hand, the information provided by green-building rating systems from GBCC, LEED, and GBTool offers additional and comparative details regarding indoor environment quality and standards regarding the IAQ performance and management plan, ventilation and thermal comfort systems, views from windows, acoustics, and lighting. In conclusion, this document provides an appropriate and easy-to-follow, self-evaluation checklist composed of eight criteria and 51 practical items. This study also provides the design recommendations composed of 27 practical ideas focusing on interior elements. Both the checklist and design recommendations I have suggested can be a post-occupancy tool for evaluating eco-healthy facility standards as well as tips for continuing to maintain eco-healthy childcare facilities.

Effect of firing temperatures on alkali activated Geopolymer mortar doped with MWCNT

  • Khater, H.M.;Gawwad, H.A. Abd El
    • Advances in nano research
    • /
    • 제3권4호
    • /
    • pp.225-242
    • /
    • 2015
  • The current investigation aims to study performance of geopolymer mortar reinforced with Multiwalled carbon nanotubes upon exposure to $200^{\circ}C$ to $1000^{\circ}C$ for 2 hrs. MWCNTs are doped into slag Geopolymer mortar matrices in the ratio of 0.0 to 0.4, % by weight of binder. Mortar composed of calcium aluminosilicate to sand (1:2), however, binder composed of 50% air cooled slag and 50% water cooled slag. Various water / binder ratios in the range of 0.114-0.129 used depending on the added MWCNT, while 6 wt., % sodium hydroxide used as an alkali activator. Results illustrate reduction in mechanical strength with temperature except specimens containing 0.1 and 0.2% MWCNT at $200^{\circ}C$, while further increase in temperature leads to decrease in strength values of the resulting geopolymer mortar. Also, decrease in firing shrinkage with MWCNT up to 0.1% at all firing temperatures up to $500^{\circ}C$ is observed, however the shrinkage values increase with temperature up to $500^{\circ}C$. Further increase on the firing temperature up to $1000^{\circ}C$ results in an increase in the volume due to expansion.

시험공간에 대한 냉방부하 실증실험 및 계산 (Verification Experiment and Calculation of Cooling Load for a Test Space)

  • 유호선;현석균;김용식;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.

유기질 단열재 종류별 수중정치기간에 따른 pH 변화에 관한 연구 (SOrganic matter insulation by type of Study on pH change according to underwater settling period)

  • 홍상훈;유남규;서은석;김해나;김봉주;정의인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2019
  • Research has been conducted in many fields for the zero energy of domestic buildings. Among them, the development of insulation has become an essential element. Accordingly, researches are being made to improve the performance of organic insulating materials, and PF boards having the lowest thermal conductivity among organic insulating materials have been in the spotlight. However, problems have arisen due to the problems of durability of insulation materials such as PF boards and past acidification, and the durability of insulation materials is deteriorated when moisture or water enters due to crack gaps during the insulation of the basement layer or the external insulation method. In regard to the durability of the insulation, when the organic insulators of different kinds were placed in water, the pH was weakly basic in all organic insulation materials except PF, and the PF was about 4 pH. As a result, the PF should be continuously reviewed, and further analysis should be carried out to determine what causes acidification.

  • PDF

지붕형 태양광발전 패널의 공장 지붕 설치에 따른 냉방 및 난방 부하 변화량 연구 (A Study of Cooling and Heating Load Changes with Roof Type Solar Panels Installed on Factory Roof)

  • 조호현;김정민;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.9-15
    • /
    • 2020
  • In this study, effect of reinforced insulation on heating and cooling loads were studied due to installation of PV panels on factory building roof with a floor area of 12,960 m2. For PV panel installation, combination of aluminum, polyurethane, air, polystyrene and steel materials were added to the original roof, which increased thermal insulation performance. Half of the roof were covered with PV panel and the other half without. Temperature and relative humidity were measured for 8 days during summer season for both indoor spaces. PV panel showed the effect of lowering the indoor space temperature by 0.6℃. TRNSYS dynamic simulation showed that with PV panel, cooling load per area is reduced by 1.7 W/m2 and heating by 10.0 W/m2. PV panels installed on building roof not only generate electricity but also can save energy by reducing cooling and heating loads.

Metaheuristic-designed systems for simultaneous simulation of thermal loads of building

  • Lin, Chang;Wang, Junsong
    • Smart Structures and Systems
    • /
    • 제29권5호
    • /
    • pp.677-691
    • /
    • 2022
  • Water cycle algorithm (WCA) has been a very effective optimization technique for complex engineering problems. This study employs the WCA for simultaneous prediction of heating load (LH) and cooling load (LC) in residential buildings. This algorithm is responsible for optimally tuning a neural network (NN). Utilizing 614 records, the behavior of the LH and LC is explored and the captured knowledge is then used to predict for 154 unanalyzed building conditions. Since the WCA is a population-based algorithm, different numbers of the searching agents were tested to find the most optimum configuration. It was observed that the best solution is discovered by 500 agents. A comparison with five newly-developed benchmark optimizers, namely equilibrium optimizer (EO), multi-tracker optimization algorithm (MTOA), slime mould algorithm (SMA), multi-verse optimizer (MVO), and electromagnetic field optimization (EFO) revealed that the WCANN predicts the desired parameters with considerably larger accuracy. Obtained root mean square errors (1.4866, 2.1296, 2.8279, 2.5727, 2.5337, and 2.3029 for the LH and 2.1767, 2.6459, 3.1821, 2.9732, 2.9616, and 2.6890 for the LC) indicated that the most reliable prediction was presented by the proposed model. The EFONN, however, provided a more time-effective solution. Lastly, an explicit predictive formula was elicited from the WCANN.

유기질 단열재 장기 흡수율에 관한 연구 (A Study on the Long-term Absorption Rate of Organic Insulation Materials)

  • 김해나;박준서;신종현;홍상훈;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.195-196
    • /
    • 2022
  • Insulation material absorption rate is closely related to thermal conductivity. In Korea, there is no study on the change of insulation material in a long-term continuous exposure environment. In this study, basic data on the long-term durability of insulation materials were obtained by measuring the absorption rate of insulation materials over time. For the purpose of providing, as a result of the measurement, PIR class2 No.2 and PIR noncombustible show similar absorption rate trends, which is thought to be due to the fact that both are made of rigid urethane foam, and flame retardant EPS has the highest absorption rate except for PF. This is thought to be because there is a space for absorption between the beads and the beads. In the case of XPS, it is thought that the reason for showing the lowest absorption rate is that because it is produced by extrusion, it has a high density and thus has less space for moisture to penetrate.

  • PDF

샌드위치 패널의 외부 색상과 내부 심재에 따른 이면 온도 변화 (The Back Side Temperature Variation According to Color of Sandwich Panel and Internal Core Material)

  • 박준서;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.25-26
    • /
    • 2023
  • The internal core material and external color of a sandwich panel have a significant impact on the performance of the sandwich panel. For use on roofs and walls, the internal core material and external color must be considered. Therefore, the surface and back side temperatures were measured for each exterior color and inner core material type. For the internal core materials, urethane foam and Expanded Poly Styrene(EPS), which are core materials mainly used in sandwich panels, were selected. As colors, black and ivory were selected according to brightness, and a total of five colors were selected: red, blue, and green, which are the three primary colors of light. As a result, there were differences in surface and temperature depending on the external color and type of internal core material. Regardless of the color, the temperature was measured lower for panels with urethane foam than for panels with an internal core of EPS. This is believed to have been influenced by the difference in thermal conductivity of urethane foam being 0.023W/(m·K) and that of EPS being 0.032W/(m·K). In addition, panels with a black exterior color were found to have higher surface and back temperatures than panels of other colors, and ivory-colored panels had lower back temperatures regardless of the core material. This is proportional to the brightness and light-absorbing characteristics.

  • PDF

The New Smart Power Modules for up to 1kW Motor Drive Application

  • Kwon, Tae-Sung;Yong, Sung-Il
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.464-471
    • /
    • 2009
  • This paper introduces a new Motion-$SPM^{TM}$ (Smart Power Modules) module in Single In-line Package (SIP), which is a fully optimized intelligent integrated IGBT inverter module for up to 1kW low power motor drive applications. This module offers a sophisticated, integrated solution and tremendous design flexibility. It also takes advantage of pliability for the arrangement of heat-sink due to two types of lead forms. It comes to be realized by employing non-punch-through (NPT) IGBT with a fast recovery diode and highly integrated building block, which features built-in HVICs and a gate driver that offers more simplicity and compactness leading to reduced costs and high reliability of the entire system. This module also provides technical advantages such as the optimized cost effective thermal performances through IMS (Insulated Metal Substrate), the high latch immunity. This paper provides an overall description of the Motion-$SPM^{TM}$ in SIP as well as actual application issues such as electrical characteristics, thermal performance, circuit configurations and power ratings.

저온 폐열을 이용하기 위한 유기랭킨 사이클의 작동유체 선정에 관한 연구 (Selection of Working fluid for the Organic Rankine Cycle to Utilize Low-Temperature Waste Heat)

  • 조수용;조종현
    • 신재생에너지
    • /
    • 제10권4호
    • /
    • pp.36-46
    • /
    • 2014
  • Low-grade heats are wasted even though an amount of their energy is huge. In the small and medium industrial complex sites, large amount of low-grade thermal energy generated during the manufacturing process is wasted if it is not used directly for building heating or air-conditioning. In order to utilize this waste thermal energy more efficiently, organic Rankine cycle (ORC) was adopted. The range of operating temperature of ORC was set to $60^{\circ}C$ from $30^{\circ}C$ applicable low-temperature waste heat. A study was conducted to select an appropriate organic working fluid based on these operating conditions. More than 60 working fluids were screened. Eleven working fluids were selected based on the requirements as working fluid for ORC such as environmentally friendly, safety, and good operation on the expander. Finally, six working fluids were selected by considering the operating temperature ranges. Then, a cycle analysis was conducted with these six working fluids. As a results, R-245fa and R-134a appeared as appropriate working fluids for ORC operating at low-temperature condition based on the system efficiency and the turbine output power.