A Study on Estimation of Cooling Load for Effective Control of Ice Thermal Storage System (빙축열 시스템의 효율적인 제어를 위한 냉방부하 예측에 관한 연구)

  • Yoo, Seong-Yeon;Han, Kyu-Hyun;Lee, Je-Myo;Han, Seung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.128-136
    • /
    • 2008
  • It is necessary to estimate the cooling load of the next day for effective control of ice thermal storage system. In this paper, new methodology is proposed to estimate the cooling load using design parameters of building and predicted weather data. Only six input parameters such as sensible heat coefficient and constant, latent heat coefficient and constant, maximum and minimum temperature are necessary to obtain hourly distribution of cooling load for the next day. Two benchmarking buildings(hospital and research institute) are selected to validate the performance of the proposed method, and the estimated cooling loads in hourly and daily bases are calculated and compared with the measured data for E hospital. The estimated results show fairly good agreement with the measured data for both buildings.

Study on Fresh Air Load Reduction System by Using Geothermal Energy - Effect on Thermal Characteristic arid Air Pattern of System by Opening Configuration - (지열을 이용한 공조외기부하저감 시스템에 관한 연구 -지하피트 공간 내의 개구부 형상이 시스템의 열적 특성 및 기류성상에 미치는 영향-)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1092-1100
    • /
    • 2004
  • This paper presents the effect of opening configuration on the thermal behavior and air pattern of earth tube system. The earth tube system is a fresh air load reduction system by using underground double floor space for air-conditioning. In order to analyze the effect of opening configuration on thermal performance of this system and air pattern in underground double floor space quantitatively, we used a model dealing with tree-dimensional profile of wind velocity and temperature in underground double floor space. In conclusion, it is confirmed that heat exchange of a fresh air is mainly performed with upper and lower wall in underground double floor space, and that heat exchange area increased by installing the opening near the wall.

Causes of local collapse of a precast industrial roof after a fire

  • Bruno Dal Lago;Paride Tucci
    • Computers and Concrete
    • /
    • v.31 no.5
    • /
    • pp.371-384
    • /
    • 2023
  • Precast roofing systems employing prestressed elements often serve as smart structural solutions for the construction of industrial buildings. The precast concrete elements usually employed are highly engineered, and often consist in thin-walled members, characterised by a complex behaviour in fire. The present study was carried out after a fire event damaged a precast industrial building made with prestressed beam and roof elements, and non-prestressed curved barrel vault elements interposed in between the spaced roof elements. As a consequence of the exposure to the fire, the main elements were found standing, although some locally damaged and distorted, and the local collapse of few curved barrel vault elements was observed in one edge row only. In order to understand and interpret the observed structural performance of the roof system under fire, a full fire safety engineering process was carried out according to the following steps: (a) realistic temperature-time curves acting on the structural elements were simulated through computational fluid dynamics, (b) temperature distribution within the concrete elements was obtained with non-linear thermal analysis in variable regime, (c) strength and deformation of the concrete elements were checked with non-linear thermal-mechanical analysis. The analysis of the results allowed to identify the causes of the local collapses occurred, attributable to the distortion caused by temperature to the elements causing loss of support in early fire stage rather than to the material strength reduction due to the progressive exposure of the elements to fire. Finally, practical hints are provided to avoid such a phenomenon to occur when designing similar structures.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

Properties of Foamed Concrete According to Types and Concentrations of Foam Agent (기포제 종류 및 희석 농도에 따른 기포 콘크리트의 특성)

  • Kim, Jin-Man;Jeong, Ji-Yong;Hwang, Eui-Hwan;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.61-70
    • /
    • 2012
  • Recently, the government has been working feverously to save energy and reduce greenhouse gas emission by enacting Basic Act on Low Carbon Green Growth at the national level. Improving the insulation performance of building exterior and insulator can reduce the energy in the building sector. This study is about developing light-weight foamed concrete insulation panel that can be applied to buildings to save energy and to find the optimal condition for the development of insulation materials that can save energy by enhancing its physical, kinetic and thermal characteristics. Various experimental factors and conditions were considered in the study such as foam agent types (AES=Alcohol Ethoxy Sulfate, AOS=Alpha-Olefin Sulfonate, VS=Vegetable Soap, FP=Fe-Protein), foam agent dilution concentration (1, 3, 5%), and foam percentage (30, 50, 70%). Experiment results indicated that the surface tension of aqueous solution including foam agent, was lower when AOS was used over other foam agents. FP produced relatively stable foams in 3% or more, which produced unstable foams containing high water content and low surface tension when diluted at low concentration. Depending on foam agent types, compressive strength and thermal conductivity were similar at low density range but showed some differences at high concentration range. In addition, when concentrations of foam agent and foaming ratio increased, pore size increased and open pores are formed. In all types of foam agent, thermal conductivity were excellent, satisfying KS standards. The most outstanding performance for insulation panel was obtained when FP 3% was used.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

A study on the relationship between the existing building load for the advance ZEB certification system (ZEB 인증제 고도화를 위한 기존 건축물 부하별 연관성 연구)

  • Lee, Hangju;Maeng, Sunyoung;Kim, Insoo;Ahn, Jong-Wook
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.21-27
    • /
    • 2018
  • In accordance with the implementation of the Zero Energy Building Certification System, it for the activation and expansion of the private sector is being steadily upgraded. Also The government has set up a step-by-step mandatory roadmap until it is expanded to the private sector, starting with the public sector. We analyzed the energy requirements of existing buildings from 2016 to 2017 and the by load relationships of major factor. Of the existing buildings, 714 buildings in central and southern areas excluding residential buildings such as apartments and officetels were classified and their primary energy requirements were analyzed. As new design technologies are applied, the demand for energy from the passive side is steadily declining. In addition, there is a need to interpret various methods to improve the zero energy building certification standard in the point that the zero energy building pilot project is continuously carried out in relation to the activation of renewable energy supply.

A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices (실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구)

  • Kim, Tae-Jung;Kang, Jae-Sik;Park, Jun-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.89-99
    • /
    • 2014
  • The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient (SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to $-45^{\circ}$, $0^{\circ}$, and$-45^{\circ}$. For the roll screen, measurements were taken with the roll screen in the closed position. In result, the venetian blind reduced SHGC by 21.2~28.4% at $45^{\circ}$, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind $-45^{\circ}$, $0^{\circ}$ and $45^{\circ}$, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.

An Experimental Study on the Effect of Air Temperature and Humidity on Humidification Performance of the Humidifying Element Used for Air Conditioning (공기 온습도가 공조용 가습 소자의 가습 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.732-740
    • /
    • 2019
  • Evaporative humidification using a humidifying element is widely used for humidification of a building or a data center. The performance of a humidifying element is commonly expressed as humidification efficiency, which is used independent of air temperature, humidity and water temperature. In this study, a series of tests were conducted at two air conditions (data center and commercial building) using two different humidifying elements (cellulose/PET and Glasdek) changing the frontal air velocity and water temperature. Results showed that the measured humidification efficiency was dependent on the air condition and water temperature. In fact, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. The reason was due to the inlet water temperature, which was lower than the dew point air temperature. As the difference between the inlet water and the dew point air temperature increased, the humidification efficiency decreased. This suggest that proper thermal model should account for the inlet region, where the amount of moisture transfer may be different from the other part of the humidification element. A simple analysis on the thermal performance of the cellulose/PET humidification element showed that the Sherwood number was adequately predicted, whereas the friction factor was ovepredicted, probably due to the simplification of the channel geometry and the neglection of the water film on the element surface.

A Basic Study on the District Cooling System of LNG Cold Thermal Energy (LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.36-43
    • /
    • 2003
  • This paper provides the possibility of the district cooling system by using a LNG cold thermal energy. A liquefied natural gas provides a plenty of cooling source energy during a gasification of a liquefied natural gas. In recent, an ice thermal storage system is used for cooling a building, and a deep water source cooling system has been introduced as a district cooling system in which is used to cool the office towers and other large buildings in old and new downtown. LNG cooling energy refers to the reuse of a large body of naturally cold fluids as a heat sink for process and comfort space cooling as an alternative of conventional, refrigerant based cooling systems. Coincident with significant clean energy and operating cost savings, LNG cold energy cooling system offers radical reductions in air-borne pollutants and the release of environmentally harmful refrigerants in comparison to the conventional air-conditioning system. This study provides useful information on the basic design concepts, environmental considerations and performance related to the application of LNG cold thermal energy.

  • PDF