• 제목/요약/키워드: Building thermal performance

검색결과 635건 처리시간 0.023초

실험을 통한 BIPV/T 시스템 성능분석-2.시스템 열성능 (Performance Analysis of the BIPV/T system by the performance Test- Part2. Thermal Performance)

  • 조혜진;이현주
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.255-259
    • /
    • 2012
  • BIPV/T (Building Intergrated PhotoVoltaic/Thermal) is combined system produces electricity and thermal energy. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. The test system is installed to top floor of the experimental house in the KEPCO Research Institute. The experimental performance is executed from 13th February to 13th March, 2012. The expected system's thermal performance is 1.9kWh under the horizontal solar radiation is $600W/m^2$ and the air flow in the system is $20CMH/m^2$.

  • PDF

Tilt & Sliding 시스템창호의 단열성능 실측과 시뮬레이션 비교 분석 (A Comparative study on the Insulation Performance of the Tilt & Sliding System Window by Actual Survey and Simulation)

  • 장철용;안병립;김치훈;홍원화
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.222-226
    • /
    • 2009
  • The parts of building which has the most influence on thermal load are skins, outer walls and windows. Among them, window is the worst weak point of building even if it has many advantage of solar radiation gain than other parts. The present time, many researches on various performance of window and many types of system-window are being made. This study evaluates thermal performance of tilt & sliding system window by simulation program Therm 5.2 and Window 5.2. After making a sample model improving it's thermal weak point, this study evaluates real thermal performance of system window. As a result, this study understands manufacture ability condition of domestic company and proposes a research plan of system window.

  • PDF

슬래브축열 공조시스템의 축열성능에 관한 실험적 연구 (An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.

빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구 (In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System)

  • 신영기;양훈철;태춘섭;조수;김영일
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.

동적 단열재의 열성능 측정에 관한 연구 (A Measurement Study of a Dynamic Insulator Thermal Performance)

  • 고선미;강은철;이의준
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.361-368
    • /
    • 2010
  • Due to the insulation and the air-tightness requirement in modern buildings have resulted NBS(New Building Syndrome) and SBS(Sick Building Syndrome) of IAQ problems. Therefore, energy efficient way of solving such IAQ issues are of major concern in these days and building industries. This paper introduces a method to improve thermal performance with a DI(Dynamic Insulation) concept. The characteristic of the dynamic insulation is that the lower U-value as the higher air velocity through the DI in a micro level. A thermal performance monitoring study has been conducted to show the energy impact of porous DI over the static insulation material. The results show that up to 45% could be improved in the case with DI compared to the conventional insulation.

주거용(住居用) 건물(建物) 외벽(外壁)의 단열공법별(斷熱工法別) 열성능(熱性能) 변동(變動)에 관한 비교(比較) 연구(硏究) (A Comparative Study on the Thermal Performance Changes by the Insulating Construction Types of Exterior Walls in Residential Buildings)

  • 김문한;조균형;김광우
    • 태양에너지
    • /
    • 제8권1호
    • /
    • pp.22-32
    • /
    • 1988
  • It is known that the energy consumption and indoor thermal comfort in residential buildings are affected by the thermal performance of building envelopes. The thermal performance of building envelopes varies with their design methods. In this study, the thermal performance changes by the insulating construction types of exterior walls were analyzed, 1) by varing the thickness of the insulation 2) by varing the location of the insulation 3) by varing the location of the plane airspace The analyzed results are presented and the thermal performance evaluating factors were compared and discussed.

  • PDF

고효율 로이유리 창호의 정량적 단열성능 평가 (An Evaluation for the Quantitative Thermal Performance of High Energy Efficiency Low-e Window)

  • 최경석;최현중;강재식;양관섭;이숭언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2006
  • In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this study is to draw up a technical counterplan for the intensification of windows energy efficiency and spread promotion by quantitative thermal performance with KS test method for a comparison between the general Pair glass windows and the Low-e pair glass windows.

  • PDF

노후건축물 벽체의 열관류율 측정 및 분석 (Measurement and Analysis on Thermal Performance of Walls for Old Building)

  • 심찬형;홍구표
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.283-284
    • /
    • 2023
  • Green remodeling of pubic buildings for improving indoor environment and reducing energy consumption is increasingly promoted. The objective of this study is to measure and analyze for wall's thermal performance, thermal transmittance, of existing buildings. The method of this present study refered the ISO 9869-1 and is to measured heat flow, surface temperature of wall, and in/outdoor temperature over 7 days. And it was compared the calculated thermal transmittance with measured one. The measured wall's thermal transmittance value is about two times than the calculated thermal transmittance value.

  • PDF

실험을 통한 BIPV/T 시스템 성능분석-1. PV 발전효율 (Performance Analysis of the BIPV/T system by the performance Test- Part1. PV efficiency)

  • 이현주;조혜진
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.445-450
    • /
    • 2012
  • BIPV/T (Building Intergrated PhotoVoltaic/Thermal) is combined system produces electricity and thermal energy. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. The efficiency of the PV system's performance will raise by the system removes heat from the PV. The test system is installed to top floor of the experimental house in the KEPCO Research Institute. The planned experiment is following. (1) Supplying heat energy to top floor. (2) Supplying heat and cool energy to thermal storage in the bottom of the top floor. (3) Supplying heat energy to EHP for improved performance. The experimental performance is executed from 13th February to 13th March, 2012. The solar generation of electricity is 4.04kWh under the horizontal solar radiation is $1000W/m^2$ and the air temperature is $25^{\circ}C$.

  • PDF

난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가 (Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis)

  • 장철용;김정국;안병립;김준섭;한찬훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF