• Title/Summary/Keyword: Building thermal performance

검색결과 635건 처리시간 0.023초

창호 리트로피트를 통한 에너지 절감 및 실내 열환경 개선 효과 분석에 관한 연구 (Energy Saving Effect and Improvement of Indoor Thermal Environment through the Window Retrofit)

  • 정진우;주정훈;조동우
    • 한국태양에너지학회 논문집
    • /
    • 제38권3호
    • /
    • pp.29-36
    • /
    • 2018
  • The goal of this study is to retrofit the windows of residential buildings and to activate the green remodeling by verifying energy saving and indoor thermal environment. As a result of analysis of the energy saving effect of 458 units window retrofits, it was possible to reduce the energy requirement by 48.20% ~ 54.97%. According to the improvement on indoor environment, it was possible to operate by reducing heating temperature and supply time. The actual gas consumption of the heating period was reduced by 25% compared with that of the window retarder to save 28,968 thousand won of heating energy cost. Resident's satisfaction surveys were conducted one year after window retrofit. More than 80% of the respondents answered that they satisfied the improvement on window performance, indoor thermal environment and indoor sound environment. As a result, we verified the energy saving effect and the improvement on the indoor environment through window retrofits.

국내 여름철 기후조건에서 DOAS와 TABS 통합시스템 냉방운전시 실내온열환경 및 운전특성 평가 (Evaluation on the Indoor Thermal Environment and Cooling Operation Characteristics of Thermally Activated Building System integrated with Dedicated Outdoor Air System during Cooling Operation in Hot and Humid Climate of Seoul)

  • 이윤선;이겨레;정웅준;임재한
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.45-55
    • /
    • 2018
  • To reduce the energy consumption of HVAC system in buildings, thermally activated building system(TABS) has been applied to low energy building because of energy efficient performance and reduction of peak load. DOAS coupled with a parallel sensible cooling could be promising because TABS handles sensible heat load only. The purpose of this study was to evaluate the indoor thermal environment and cooling operation characteristic of TABS with dedicated outdoor air system(DOAS) in Korea climate. Indoor thermal environment and operation characteristic of TABS integrated with DOAS are investigated at different TABS operation schedules and climate conditions by simulation tests. The result shows that the DOAS is more suitable for hot and humid climates. And also it show that the potential of intermittent operation of TABS.

건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구 (An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.203-211
    • /
    • 2021
  • 최근 건축물의 에너지 사용 저감을 위한 단열 설계기준은 강화되고 있다. 단열공사는 건축물의 단위면적당 1차 에너지 소요량 저감을 위한 가장 효율적인 방법임에도 불구하고, 건축 시공 및 준공검사 과정에서 단열성능에 대한 평가(검사) 기준이 없는 실정이다. 본 연구는 열관류율 측정장비(TESTO 435)를 활용하여 공동주택의 외벽 열관류율을 간편하게 실험 할 수 있는 방법과 분석기법에 대한 기준을 구축하여 객관적인 데이터를 제공하는 데 목적이 있다. 실험 대상 외벽의 단위면적당 비열(열용량)이 20 kJ(m2·K)를 초과하여 ISO 9869-1에 적합한 종료 시점의 데이터를 평균법으로 분석했다. 3일 연속 열관류율 측정값은 설계값 대비 +5% 이내로 허용오차 범위 내로 수렴했고, 일자별 열관류율의 표준편차는 1-Day > 3-Day > 2-Day 순으로 작아졌고, 시간대별 열관류율 표준편차는 00:00~24:00 > 19:00~07:00 > 00:00~07:00 순으로 줄어 들었다. 특히, 측정일자별로 00:00~07:00 시간대의 열관류율 값은 설계값 대비 -3%~+2% 편차로 거의 일치하였다.

단열 기준에 따른 기둥-보 목조주택의 단열 상세 및 에너지 성능 (Insulation Details and Energy Performance of Post-Beam Timber House for Insulation Standards)

  • 김세종;박주생
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.876-883
    • /
    • 2015
  • 국립산림과학원에서는 한옥의 전통건축기술을 바탕으로 한국형 기둥-보 목조주택인 ?그린 프로젝트를 2006년부터 진행해오고 있다. 최근에는 에너지 절약 기술요소를 적용하여 건물의 에너지성능을 개선하고자 하였다. 본 연구에서는 강화된 단열기준에 따른 기둥-보 목조벽체의 단열상세를 제시하고 그에 따른 건물 에너지 절감 효과를 평가하고자 하였다. 건물외피의 열관류율은 현행법 수준과 저에너지주택인 패시브하우스 수준인 두 단계로 나누었으며 건물에너지 성능을 평가하기 위하여 건물의 기밀성능은 국내 신축 목조주택 수준인 $3.0h^{-1}$과 패시브하우스 수준이 $0.6h^{-1}$ 두 단계로 나누어 열관류율과 기밀성능의 조합에 따라 4가지 경우에 대한 건물에너지 성능 평가가 이루어졌다. 대상건물은 서울에 위치하였으며 에너지 성능은 상용 건물에너지성능 평가 프로그램인 CE3가 사용되었다. 강화된 열관류율에 따라 시뮬레이션을 진행한 결과 연간 난방에너지 요구량은 $14kWh/(m^2{\cdot}a)$ 절감효과를 나타냈다.

지역별 건물에너지 효율에 관한 슈퍼윈도우 단열 성능 평가 연구 (A Study on the Insulation Performance of the Super window considering the evaluation of Building Energy Rating)

  • 장철용;안병립;김치훈;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.39-44
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficience rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

A NUMERICAL INVESTIGATION OF INDOOR AIR QUALITY WITH CFD

  • Sin Vai Kuong;Sun Ho I
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.87-93
    • /
    • 2005
  • Macao, a city with three sides bounded by water, is hot and humid in weather in more than six months of a year. This uncomfortable weather induces the frequency of operating air-conditioners. Choice of location for installation of air-conditioner in a building will affect the performance of cooling effect and thermal comfort on the occupants, which in turn will affect the indoor air quality (IAQ) of the building. In the paper, investigation of distribution on carbon dioxide, room air temperature and velocity, as well as air diffusion performance index (ADPI) of a single bedroom in Macao is studied by using the computational fluid dynamics (CFD) software FLOVENT 3.2. Simulations of locating the air-conditioner at 4 different walls will be done and comparisons and analyses of the results will be performed to decide a proper location for the air-conditioner for obtaining good thermal comfort.

전기열풍기를 이용한 동절기 콘크리트 가열양생공법 적용 및 적정성 효과 검증 (Confirmation of Applicability of Heating and Curing Method of Concrete in Winter Using Electric Heating System)

  • 김세종;박종훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.131-132
    • /
    • 2022
  • Looking at recent construction cases at winter construction sites, there is a risk that heat sources such as kerosene fans and fossil fuels (brown coal, molded carbon) used in concrete will cure rapidly, so in situations where further curing is impossible after formwork removal, the outer wall and the entire slab are exposed to rapid external deterioration, resulting in delays in concrete strength expression and until collapse accidents. In this study, we applied kerosene fans and tropical circulating electric heat fans mainly used as curing heat sources at construction sites, comparative analysis. also verified the performance of structures during concrete curing due to thermal convention / circulation performance, concrete demand strength expression, and implementation of electric heat fans by heavy disaster methods.

  • PDF

목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석 (Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material)

  • 서정기;정수광;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권3호
    • /
    • pp.343-359
    • /
    • 2017
  • 건축물에서 사용되는 에너지를 줄이기 위하여 다양한 연구 및 정책이 진행되고 있으나 건축물에서 구조재 및 실내 외 마감재로 폭넓게 사용되는 목재의 열적 특성에 관한 연구는 미미한 실정이다. 이에 따라, 본 연구는 목질재료와 비 목질재료의 전열성능을 분석하기 위하여 목질재료가 주로 이용되는 주거용 건축물을 대상으로 열성능이 취약한(열교 발생) 부위를 선정하고, 각 부위별로 구조재와 마감재의 구성에 따라 총 16 Case에 대해 전열성능 분석을 실시하였다. 전열 해석 시뮬레이션 도구는 ISO 10211의 계산 방법을 따르는 Physibel Trisco를 이용하였다. 해석 부위의 모델링 역시 ISO 10211에서 제시된 기준에 의해 실시하였으며, 경계 온도 조건은 에너지절약설계기준에 따라 실내온도 $20^{\circ}C$, 실외온도 $-11.3^{\circ}C$(서울 기준)로 설정하였다. 구조는 콘크리트구조와 비 목질재료마감, 콘크리트구조와 목질재료마감 그리고 목구조에 목질재료마감의 경우에 따라 구분하였다. 부위는 벽체, 지붕, 층간바닥 및 최하층 바닥 등으로 구분하여 시뮬레이션을 진행하였다. 결과로서, 콘크리트구조의 경우 형상적 원인에 의해, 목구조의 경우 형상적인 원인에 재료적 원인이 더해져 다발적으로 열교가 발생함을 확인할 수 있었다. 추가적으로 콘크리트구조에서는 단열재의 불연속 부위에서 구조적인 열교가 발생하고 목구조에서는 구조적인 열교와 이질재료의 적용 부위에서 재료적 원인에 의한 열교가 발생하는 것을 확인할 수 있었다. 또한 콘크리트 구조에 목질 실내마감재를 적용하였을 경우에는 벽체의 선형 열관류율 값이 감소하는 것을 확인할 수 있었다.

IGBT 배열과 설치 위치에 따른 히트 싱크 방열 성능 (Thermal Performance of a Heat Sink According to Insulated Gate Bipolar Transistor Array and Installation Location)

  • 박승재;윤영찬;이태희;이관수
    • 설비공학논문집
    • /
    • 제30권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Thermal performance of a heat sink for an inverter power stack was analyzed in terms of array and installation location of an Insulated Gate Bipolar Transistor (IGBT). Thermal flow around the heat sink was calculated with a numerical model that could simulate forced convection. Thermal performance was calculated depending on the array and location of high- and low-power IGBTs considering the maximum temperature of IGBT. The optimum array and installation location were found and causes were analyzed based on results of numerical analysis. For the numerical analysis, experiment design considered the installation location of IGBT, ratio of heat generation rates of high- and low-power IGBTs, and velocity of the inlet air as design variables. Based on numerical results, a correlation that could calculate thermal performance of the heat sink was suggested and the maximum temperature of the IGBT could be predicted depending on the installation method.

공동주택에서의 실내환경의 질 평가에 관한 연구 - 미국 공동주택 사례를 중심으로 - (A Study on Indoor Environmental Quality Evaluation in Apartment Buildings - Focus on Apartment Buildings in USA -)

  • 윤성훈
    • 한국실내디자인학회논문집
    • /
    • 제18권4호
    • /
    • pp.79-87
    • /
    • 2009
  • Residential Buildings should provide high-quality, comfortable environments to support the activities of their occupants. The indoor environment of residential buildings, which includes thermal, lighting, acoustic, and indoor air quality, has a significant impact on health and quality of life. The comfortable living environment in residential buildings result from appropriately combining these environmental quality factors, and the performance of building systems must be compatible with the activities of the occupants. The objective of this research is to investigate and analyze the relationship between physical environmental conditions and occupant responses for improving environmental quality (EQ) in apartment buildings with four different building orientations (i.e. E, W, S, N) in two different seasons (i.e. winter and summer). The occupant survey was conducted in actual apartment buildings. The Physical environmental conditions in apartment buildings differed substantially depending on space, outdoor weather conditions and building orientations. Each space within the same apartment building had different environmental conditions. Combinations of unbalanced physical environmental conditions in apartment building decrease occupants' satisfactions and their perceptions of overall residential quality. Occupants' satisfaction and their responses to physical characteristics of their residential environment is related to thermal, lighting, acoustic, and indoor air conditions in their buildings. The result from this research will help designers and researchers to identify problems and develop solutions for improving environmental quality from the occupants' point of view.