• 제목/요약/키워드: Building thermal performance

검색결과 634건 처리시간 0.029초

3L House의 설계, 시공 및 평가 (The Technology Applied 3 Liter House, Super Energy Saving Building)

  • 박선효;박용승;원종서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.814-819
    • /
    • 2006
  • This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

  • PDF

창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석 (A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size)

  • 김성범;이수열;김동윤;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

하중재하조건을 고려한 초고강도 콘크리트의 열변형거동특성 평가 (Evaluation on Thermal Strain Behavior Properties of Ultra High Strength Concrete considering Load)

  • 이영욱;김규용;최경철;김홍섭;이보경;윤민호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.162-163
    • /
    • 2015
  • Thermal deformation behavior of high-strength concrete (HSC) exposed to fire is different from that of normal strength concrete (NSC). In case of ultra-high-strength concrete (UHSC), it is well known that thermal deformation behavior is greater than HSC. With increasing research of UHSC in buildings, it is necessary to understand the performance of UHSC at elevated temperatures considering loading condition. Therefore, evaluation on properties of thermal strain behavior properties of ultra high strength concrete by loading and high temperature was conducted.

  • PDF

하중재하조건을 고려한 초고강도 콘크리트의 열변형거동특성 평가 (Evaluation on Thermal Strain Behavior Properties of Ultra High Strength Concrete considering Load)

  • 이영욱;김규용;최경철;김홍섭;이보경;윤민호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.80-81
    • /
    • 2015
  • Thermal deformation behavior of high-strength concrete (HSC) exposed to fire is different from that of normal strength concrete (NSC). In case of ultra-high-strength concrete (UHSC), it is well known that thermal deformation behavior is greater than HSC. With increasing research of UHSC in buildings, it is necessary to understand the performance of UHSC at elevated temperatures considering loading condition. Therefore, evaluation on properties of thermal strain behavior properties of ultra high strength concrete by loading and high temperature was conducted.

  • PDF

혼합 양에 따른 경질 폴리우레탄폼의 밀도 및 열전도율에 관한 연구 (A Study on the Density and Thermal Conductivity of Rigid Polyurethane Foam According to Mixing Amount)

  • 신종현;조수연;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.127-128
    • /
    • 2021
  • Rigid urethane foam is widely applied because it is light and has superior insulation performance compared to insulation materials such as EPS or glass wool. However, it has the disadvantage of being vulnerable to fire. Therefore, in this study, before proceeding with the research to improve the fire resistance of the rigid polyurethane foam, we would like to investigate the change in density and thermal conductivity of the rigid polyurethane foam according to the change in the mixed weight of the main material and the curing agent. It was found that the density increased as the mixed weight increased. The thermal conductivity showed similar values overall. As for the density distribution, the central part was low and the outer part was high.

  • PDF

파라핀 기반 상변화 물질을 이용한 태양광 반사 페인트 개발에 관한 연구 (Paraffin-Based Phase Change Materials for Solar Reflective Paints Applications)

  • 잔낫;소우멘 만달;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.67-68
    • /
    • 2023
  • This paper reports on the synthesis of paraffin-based phase change materials (PCMs) designed for use in solar reflective paint (SRP) as a thermal energy storage (TES) medium. These PCMs are prepared using the sol-gel process and are encapsulated in silica. The focus of this research is to evaluate the suitability of these synthesized PCMs for efficient thermal energy storage within SRP applications. The obtained PCMs have nanometric dimensions, which make them well-suited for integration into paint formulations. The study also includes a thorough analysis of the chemical, thermal, and structural stabilities of these materials, confirming their applicability in solar reflective paint.

  • PDF

건물 냉난방수배관의 단열성능 향상을 위한 기준 연구 (A Standard Study for Improving Thermal Performance of the Hot and Cold Water Pipe Insulation in Buildings)

  • 최승혁;김유승;윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.21-30
    • /
    • 2017
  • Recently, It has increased the importance of building energy saving. Pipe insulation as well as building envelope insulation is to improve energy efficiency and reduce the energy loss. However, there continues to use the old standard for pipe insulation that is one of the most important elements in energy savings in buildings. The purpose of this study is to propose suitable pipe insulation thickness for reducing building energy use. The study also reviews pipe insulation thickness standard in accordance to Korea standard, ASHRAE 90.1 and BS5422 and analyzed through thermal simulation. As a result, it is necessary to apply the performance design method of the pipe insulation thickness to reduce the energy loss of the piping.

발코니 확장비용 가이드라인에 따른 창호 열성능 분석 (Analysis of Window Thermal Performance according to Guidelines on the Balcony Expansion Costs)

  • 최경석;강재식;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.863-868
    • /
    • 2008
  • In accordance with the guidelines on the balcony structure changes in December 2005, most of tenants were moving into apartment housing, expand the balcony, but some large deviation between the price construction costs set of cases, due to overuse and the cause of the dispute, and the housing law amended in 2007 due to price cap system is implemented, the cost of expansion the balcony overdose pointed out that there is set to boost the sale price has been raised. These issues in order to improve the government in January 2008, the "Note costs by the balcony expansion" suggested guidelines to protect the rights of tenants and wants to promote the settlement of the sale price cap system. This study calculated the "Note costs by the balcony expansion" window system based on double or single, high performance insulation window system of the quantitative performance analysis of each type window that purpose.

  • PDF

공기식 집열 지붕 난방시스템의 실험 연구 (An Experimental Study of Solar fir Roof Heating System With PVT Collector)

  • 강준구;김진희;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.232-237
    • /
    • 2008
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This research is about the development of solar roof system with PV/T collector to apply into buildings. A test cell experiment was performed with the PVT roof installed: It found that the hot air supply from the PVT air collector contributed to increase the heating efficiency by 2 times and the electrical efficiency by about 8%.

  • PDF

PHC 파일 기초를 이용한 지중 열교환기 개발 및 성능 평가 (Development & Performance Evaluation of Ground Heat Exchanger Utilizing PHC Pile Foundation of Building)

  • 유형규
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.56-64
    • /
    • 2008
  • The objective of this study is to develope ground heat exchanger using PHC file used to building foundation, and it's element technology. So we construct PHC ground heat exchanger in the apartment house's PHC foundation and evaluate it's performance. First, we study PHC file type, heat exchanger pipe, grouting materials, and present apartment house's foundation condition for PHC ground heat exchanger and design it's proto type. Second according to grouting materials, we estimate construction convenience, and it's performance. Construction convenience side, PB 22 A pipe and sand grouting with moisture was good for PHC ground heat exchanger elements. Experiment result is very superior. Thermal conductivity B, C type(sand, gravel) was respectively 32.4 W/m$^{\circ}C$, 36.5 W/m$^{\circ}C$, D(concrete) Type 27.8 W/m$^{\circ}C$, E(bentonite) Type 19.6 W/m$^{\circ}C$. Thermal interference for 4 day experiment period in 3.8 m was very small. So PHC file is good for using ground heat exchanger.