• Title/Summary/Keyword: Building energy demand

Search Result 339, Processing Time 0.021 seconds

Energy Economic Analysis of Standard Rural House Model with PV System (PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석)

  • Lee, Chan Kyu;Kim, Woo Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1540-1547
    • /
    • 2013
  • The energy economic analysis of the standard rural house model with PV system was performed based on annual energy demand calculation using the EnergyPlus to contribute in reducing building energy which occupies 25% of national energy consumption and in developing a low-energy & eco-friendly house model. Two types of PV system installation was considered to cover electricity demand for cooling, electric, and heating devices. For the selected house model, heating energy demand is 7 times higher than cooling energy demand. For the Case1, it is favorable to use electricity from PV system for cooling and electric devices and to sell surplus electricity. For the Case2, it is favorable to use electricity from PV system for cooling, electricity and heating devices and to sell surplus electricity. Considering the installation cost of PV system and heat pump air conditioning system, the break-even point of Case1 and Case2 are about 13 and 11 years respectively. Although the installation cost of Case2 is more expensive, Case2 provides three times more profit than Case1 after the break-even point. Because the expected average life time of the selected PV system is 25 years, Case2 is more favorable option for the given standard rural house model.

Deformation Demand of the Precast Concrete Frame Buildings with Ductile Connection in Moderate Seismic Regions (연성적인 접합부를 가진 프리캐스트 콘크리트 골조건물의 변형수요)

  • 서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.89-98
    • /
    • 1999
  • This paper evaluates nonlinear response characteristics of precast concrete frame buildings. where plastics hinging occurs in the precast connection. Designs were developed for buildings of 5, 10 and 15 stories in hight for moderate seismic risk regions of the U. S. The responses of the buildings were analyzed using DRAIN-2DX and following Nonlinear static analysis procedure of ATC 19. The main variables of the analyses were the strength and stiffness of the connection. Also, for the analysis, the bi-linear response model, developed and inserted into the DRAIN-2DX program by Shan Shi and D. Fouch, was used. With the results of analysis, the deformation demands of the connection of precast concrete frame buildings are proposed by using equal-dissipated energy capacity. It was shown that the strength of the buildings as well as their displacement capacities decreased with the decrease of either the strength or stiffness in the connections. Therefore such changes also require reductions in the response modification factors for such buildings. However, if the precast concrete frame building has plastic hinging in the connection, and has a more ductile connection than the monolithic frame building, then no reduction in R may be necessary. The deformation demand required of the connection to achieve that condition is evaluated and a simple relation is suggested in the paper.

Time series analysis of the electricity demand in a residential building in South Korea (주거용 건물의 전력 사용량에 대한 시계열 분석 및 예측)

  • Park, Kyeongmi;Kim, Jaehee
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.3
    • /
    • pp.405-421
    • /
    • 2019
  • Predicting how much energy to use is an important issue in society. However, it is more difficult to capture the usage characteristics of residential buildings than other buildings. This paper provides time series analysis methods for electricity consumption in a residential building. Temperature is closely related to electricity demand. An error correction model, which is a method of adjusting the error with time, is applied when a cointegration relation is established between variables. Therefore, we analyze data via ECMs with consideration of the temperature effect.

Optimal earthquake intensity measures for probabilistic seismic demand models of ARP1400 reactor containment building

  • Nguyen, Duy-Duan;Thusa, Bidhek;Azad, Md Samdani;Tran, Viet-Linh;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4179-4188
    • /
    • 2021
  • This study identifies efficient earthquake intensity measures (IMs) for seismic performances and fragility evaluations of the reactor containment building (RCB) in the advanced power reactor 1400 (APR1400) nuclear power plant (NPP). The computational model of RCB is constructed using the beam-truss model (BTM) for nonlinear analyses. A total of 90 ground motion records and 20 different IMs are employed for numerical analyses. A series of nonlinear time-history analyses are performed to monitor maximum floor displacements and accelerations of RCB. Then, probabilistic seismic demand models of RCB are developed for each IM. Statistical parameters including coefficient of determination (R2), dispersion (i.e. standard deviation), practicality, and proficiency are calculated to recognize strongly correlated IMs with the seismic performance of the NPP structure. The numerical results show that the optimal IMs are spectral acceleration, spectral velocity, spectral displacement at the fundamental period, acceleration spectrum intensity, effective peak acceleration, peak ground acceleration, A95, and sustained maximum acceleration. Moreover, weakly related IMs to the seismic performance of RCB are peak ground displacement, root-mean-square of displacement, specific energy density, root-mean-square of velocity, peak ground velocity, Housner intensity, velocity spectrum intensity, and sustained maximum velocity. Finally, a set of fragility curves of RCB are developed for optimal IMs.

Optimization of the Community Energy Supply System for D-Cube City, Multi Purpose Building (복합건물(D-Cube City) 지역에너지 공급체계 최적화)

  • Lee, Tae-Won;Kim, Yong-Ki;Lee, Kun-Woo;Lee, Ki-Bong;Cho, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.669-674
    • /
    • 2012
  • D-Cube City is a recently completed multi purpose building consisting of four types of facilities; offices, a department store, a hotel, and congregation spaces. A community energy supply system(CES) has been installed to supply this building with electricity, steam, heat, and cold water. The BEMS, building energy management system, is currently being designed to reduce building energy consumption through the efficient operation of the various pieces of building service equipment. In this study the optimal methods for operating the CES of D-Cube City were considered. This system includes three combined heat and power systems, seven steam boilers, two hot water boilers, two absorption chillers, and four turbo chillers, and various other pieces of equipment. In result, the optimal methods of operating the CES for various energy demand levels were obtained along with the seasonal effects on the economic efficiency of the operation. The effect of the amount of energy demanded by the various facility areas on the total energy consumption was also analyzed.

Comparison Analysis of Cooling and Heating Demand by Building Type and Region using ECO2 and TRNSYS (건물유형 및 지역조건에 따른 ECO2 및 TRNSYS의 냉난방부하 비교분석)

  • Dongjin Park;Hyunjae Lee;Jinhwan Oh;Youngsik Kwon;Jaekwang Yang;Yujin Nam
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2023
  • In Korea, it is also mandatory for most buildings to receive energy efficiency rating certification from 2020 for the purpose of reducing greenhouse gas emissions and expanding green buildings. However, the issue of the accuracy of the ECO2 program continues to be raised, and comparisons have been made with dynamic energy analysis programs in a single type of building according to a single area. However, comparisons between multiple building types and multiple areas are insufficient. Therefore, in this study, cooling and heating loads according to multiple building types and multiple areas were analyzed through ECO2 and TRNSYS programs. The regions were supposed to be Seoul, Daejeon, Gwangju, and Busan and the building types were supposed to be office buildings and apartment houses. The annual average building load values from ECO2 were higher than those from TRNSYS. Among residential buildings across the four regions, the largest discrepancy was 41.4% in Seoul. Conversely, for commercial buildings, the most significant difference in annual average loads was noted in Gwangju, at 37.9%.

Analysis of Application Elements for improvement in the generated electric power performance of balcony BIPV System (발코니형 BIPV시스템의 발전성능 향상을 위한 적용요소기술 분석)

  • Kim Hyun-Il;Yu Gwon-Jong;Kang Gi-Hwan;So Jung-Hoon;Lee Kil-Song
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1483-1485
    • /
    • 2004
  • Photovoltaic(PV) technology is a popular part of building vocabulary. It can be used today on both existing and new buildings. Its use in the building envelope is very varied and open ways, such as roofing materials, facades, skylights and shading systems, for creative designers. So, to activate this systems demand appropriate sources of information, performance data of elements and design tools offering architects and designer. Therefore this paper describe application elements for BIPV system and then predict improvement in the generated electric power performance of balcony BIPV system.

  • PDF

Study on Insulation Standards at Passive Level of Non-Residential Buildings by Regional Climate (지역별 기후에 따른 비주거 건축물 패시브 수준 단열기준 연구)

  • Kim, Yeweon;Yu, Ki-Hyoung
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.51-58
    • /
    • 2017
  • This study proposes an appropriate level of insulation standards by region through annual heating energy requirements according to regional climate. The reference buildings out of non-residential buildings approved by the energy saving design standard for buildings were derived in the previous study, in which the annual heating energy requirements for each building were as follows when the insulation standard for building members in four regions (Pyeongchang, Seoul, Gwang-ju, and Jeju) suggested by the energy saving design standard for buildings: $29.8kWh/m^2$ in Pyeongchang, $17.5kWh/m^2$ in Seoul, $14.4kWh/m^2$ in Gwangju, and $16.7kWh/m^2$ in Jeju. To satisfy the passive level of insulation standards for these buildings, in case that roof/floor of buildings in Pyeongchang and Seoul was $0.2W/m^2K$, the minimum window thermal transmittance should satisfy $0.9W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.1W/m^2K$ in the case of Pyeongchang. On the other hand, the minimum window thermal transmittance should satisfy $1.5W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.14W/m^2K$ in the case of Seoul. For Jeju regions, the minimum wall thermal transmittance should satisfy $0.34W/m^2K$ to meet the passive level of buildings. Based on the above results, the thermal transmittance of each member by region should take the outdoor climate condition of the region into consideration to satisfy the passive level of buildings.

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep;Petwal, Sandeep
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.401-413
    • /
    • 2019
  • The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.

Application of District Cooling System for Deep Ocean Water by Case Study (사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안)

  • Jin, Su-Hwuy;Park, Jin-Young;Kim, Sam-Uel;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF