• 제목/요약/키워드: Building Structure

검색결과 4,808건 처리시간 0.034초

내진여유도평가법에 근거한 기존 강구조물의 내진성능평가 (Evaluation of Seismic Margin of Existing Steel Structure Based on Seismic Margin Assessment)

  • 황규호;송정국;강선구;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.239-249
    • /
    • 2002
  • The Turbine Building of nuclear power plant is classified as non safety-related structure. During the operation, there may be possibility the original licensing basis would be changed, which makes non safety-related structure safety-related. Such a change in regulation requires utility to perform seismic qualification for the existing structure and their facilities. Thus it is meaningful to evaluate seismic margin of the existing non-qualified building structure. In addition, in this paper it is shown that a modification to the structure can enhance their seismic capacity.

  • PDF

수정된 능력스펙트럼을 이용한 건축구조물의 내진성능평가 (Seismic Performance Evaluation of Building Structures Using Modified Capacity Spectrum)

  • 최원호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.267-274
    • /
    • 2000
  • Current seismic design codes for building structures are based on the method which can provide enough capacity to satisfy objected performance level and exactly evaluate the seismic performance of buildings. The capacity spectrum method using the nonlinear static(pushover) analysis is becoming a popular tool for evaluating the seismic performance of existing and new building structures. By means of a graphical procedure capacity spectrum method esimates the performance level of structure by comparing the capacity of structure with the demand of earthquake ground motion on the structure. In the method the relation between base shear estimated by a nonlinear static analysis and horizontal displacement is used. Capacity spectrum is usually expressed as what represent the responses of the equivalent single degree of freedom (ESDOF) system for the building structures. However there are some problems in converting procedures into ESDOF system which include not considering the effect of higher modes of structures. The objective of this paper is to compare and verify existing methods and suggest the modified capacity spectrum for seismic performance evaluation of building structures.

  • PDF

BIM-Based Simulator for Rebar Placement

  • Park, U-Yeol
    • 한국건축시공학회지
    • /
    • 제12권1호
    • /
    • pp.98-107
    • /
    • 2012
  • Reinforcing bars (rebar) comprise an integral part of a concrete structure, and play a major role in the safety and durability of the building. However, the actual placement or installation of rebar is not planned and controlled by the detailer. Recently, 4D simulations, using 3D model and scheduling software, have been used to improve the efficiency of the construction phrase. However, 4D simulators have not been introduced at the detailed level of work, such as rebar placement. Therefore, this paper suggests a BIM-based simulator for rebar placement to determine the sequence with which rebar is placed into the form. The system using Autodesk Revit API automatically generates rebar placement plans for a building structure, and labels the placement sequence of each individual bar or set of bars with ascending numbers. The placement sequence is then visualized using Autodesk Revit Structure 2012. This paper provides a short description of a field assessment and limits.

석재 외피 시공을 위한 알루미늄 빔 지지공법 연구 (A study on the Aluminium Beam Methods for Building a Stone Finished Envelope)

  • 김장욱;이영래;홍성욱;도선붕;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.235-242
    • /
    • 2012
  • In recently constructed building, It has become fashionable again that the heavy external skin system such as a Stone Finished Envelope. There are Squared Steel Pipe Methods, C-Shaped Steel Pipe Methods, and Aluminum Beam Methods in the structure of a heavy external skin system. The Aluminum Beam Methods is often misunderstood as a Plane Truss Structure, but this method is not appropriate to be called to a truss structure but a beam methods. The Aluminum Beam Methods is the most Eco-friendly methods in terms of Quality assurance, Efficiency, Safety, Construction period, Durability, and Recyclability. And this Methods is also very appropriate in considering the point of Energy conservation, Waste reduction, Long-life architecture, Replacement parts, Environmental protection, Public efficiency, and Building demolition.

  • PDF

공동주택 하자감정서의 구성체계 분석 (Analysis on the Structure of Defect Consulting Report in Apartment Building)

  • 박준모;서덕석;김옥규;박길범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.166-167
    • /
    • 2013
  • There has been a defect dispute of apartment building in Korea. The defect dispute is complicated by main issues and details of dispute. It is yet to be solved. Meanwhile, a judge does not a inspection and analysis, but, related field expert who contracted professional engineer does. As a result, defect consulting report that an important judgment is used in a defect dispute. Therefore, this study does research on structure of defect consulting report. A defect consulting report has same items, irrespective of a defect consultant as a result that check 7 indexes about 10 cases. It has different structure's details depending on each defect consultants. And, it inserts new detail or deletes existing detail, does not show clear distinction.

  • PDF

지하철 주행에 의한 건물내 고체음 (Structure-borne noise in a house generated by the subway operation)

  • 채수연
    • 기술사
    • /
    • 제19권2호
    • /
    • pp.21-25
    • /
    • 1986
  • Structure-borne noise due to forced vibration which is originated from subway operation and transmitted to buildings in order of rail-wood tie-concrete bed-structure-soil-building foundations-members of building results in social problem of environmental pollution. Moreover this becomes a serious problem because of the increment of surface traffic and subway operation made by meeting traffic system in crowded cities. Since subway is constructed along the principal road or through the residential area and as the worst case may be, building foundations is contact with top part of subway structure, it is possible that vibration resonance results in fatal damage of buildings. And, structure-borne vibration noise due to subway operation at late and early hours have the residents suffer from insonmia, restlessness and so on. Therefore, to satisfy the future need concerning the environmental protection, this report deals with the influence of structure-borne vibration noise on the basis of the characteristics of Seoul Subway System.

  • PDF

폭발에 의한 건축물 붕괴 시 매몰공동 위치 예측에 관한 수치해석 사례 연구 (Numerical Simulation for Prediction of Existing Cavity Location on Explosion-Induced Building Collapse)

  • 정자혜;박훈;김광염;신휴성
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.94-101
    • /
    • 2015
  • When a severe disaster such as a building collapse occurs, a first priority for rapid rescue is to find a location where people are highly expected to be buried but alive. It is, however, very difficult to correctly designate the location of such cavities by conventional geophysical survey due to a pile of debris of building members. In this study, location of possible lifeguard cavities were evaluated through a series of simulations of building collapse by explosion depending on the height of the building, a structure of basement floor and a location of explosion. Three types of building structure: five-story, ten-story and fifteen-story were prepared as a model for the simulation. As a results, in the case of low building, only basement floor partially collapsed. On the other hand, in the case of high building, a collapsed range on the inside of the building increased and lifeguard spaces were formed only in the lateral side or corner of the building. In addition, when a wall exists in the basement floor, the possibility that cavities could be formed increased compared to the cases without wall. However, for the fifteen-story building case, no possible lifeguard cavity was found. It is noted that for a high rise building, the height of building more affect forming of safeguard cavity than the structure of the basement floor.

초고강도 콘크리트를 이용한 CFT실물대 실험 (An Experimental Study on the Mock-up test take advantage of the High Strength Concrete)

  • 손영준;김재은;양동일;정근호;임남기;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.458-461
    • /
    • 2004
  • The column for Steel Framed Reinforced Concrete Structure (SFRCS) and the column for Reinforced Concrete Structure (RCS) could be the most common building structure. The increasing of the need for massive space hasaffected the size of building components for supporting the massive structure. However, the changing of components size makes inefficient space of building. Hence. to meet the need for acquiring efficient space comparing the budget and cost the new structure method, Concrete Filled Tube Steel (CFT), was developed. CFT is the structure for which steel tube instead of other materials such as wood for holding concrete is used. The most benefit of this one is to help in reducing the size of the building components and local buckling because of tube steel holding concrete. For this reason, this research will examine the probability of applying CFT on construction sites by using the concrete $(800kg/cm^2)$ especially for CFT through the data from the real size mock-up.

  • PDF

기반암의 전단파속도를 고려한 지진파의 통과시차가 건물의 지진거동에 미치는 영향 (Wave Passage Effect on the Seismic Response of a Building considering Bedrock Shear Wave Velocity)

  • 김용석
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.89-94
    • /
    • 2014
  • Spatial variations of a seismic wave are mainly wave passage and wave scattering. Wave passage effect is produced by changed characteristics of exciting seismic input motions applied to the bedrock. Modified input motions travel horizontally with time differences determined by apparent shear wave velocity of the bedrock. In this study, wave passage effect on the seismic response of a structure-soil system is investigated by modifying the finite element software of P3DASS (Pseudo 3-Dimensional Dynamic Analysis of a Structure-soil System) to apply inconsistent (time-delayed) seismic input motions along the soft soil-bedrock interface. Study results show that foundation size affected on the seismic response of a structure excited with inconsistent input motions in the lower period range below 0.5 seconds, and seismic responses of a structure were decreased considerably in the lower period range around 0.05 seconds due to the wave passage. Also, shear wave velocity of the bedrock affected on the seismic response of a structure in the lower period range below 0.3 seconds, with significant reduction of the seismic response for smaller shear wave velocity of the bedrock reaching approximately 20% for an apparent shear wave velocity of 1000m/s at a period of 0.05 seconds. Finally, it is concluded that wave passage effect reduces the seismic response of a structure in the lower period range when the bedrock under a soft soil is soft or the bedrock is located very deeply, and wave passage is beneficial for the seismic design of a short period structure like a nuclear container building or a stiff low-rise building.