• Title/Summary/Keyword: Building Material

Search Result 2,834, Processing Time 0.026 seconds

Analyzing the Weight of Assessment Criteria in Korea Green Building Certification System - Focused on Certification Standards for Multi-unit Apartment Projects - (국내 친환경 건축물 인증제도 평가항목의 중요도 분석 - 공동주택 인증심사기준 중심으로 -)

  • Choi, Yeo-Jin;Lhee, Sang-Choon
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.83-90
    • /
    • 2012
  • Over the world, social demands and concerns of energy and resource depletions and environmental conservation have resulted in many researches and applications on sustainable development and construction. In order to support these demands and concerns, international green building certification systems such as LEED(Leadership in Energy and Environmental Design) and BREEAM(Building Research Establishment Environmental Assessment Method) were developed. In Korea, the green building certification system was introduced in 2000 and widely applied to all types of new buildings in order to induce the diffusion of sustainable buildings on May, 2010. This paper investigates the importance of assessment criteria on multi-unit apartment projects among certification rating systems using the AHP(Analytic Hierarchy Process) method and suggests a new direction on certification assessment standards. For applying the AHP method, the survey of staffs in green building certification consulting companies and architectural design companies was conducted via e-mail. As a result, criteria like energy, indoor environment, land use, pollution control, and ecological environment among 9 main ones turned out important on assessing green building certification at multi-unit apartment projects, while criteria like water resource, transportation, maintenance management, and material and resource did relatively unimportant.

Study on the Waterproofing Performance of FGD Gypsum Building Products from Inorganic-Organic Composite Additives

  • Ding, Yi;Fang, Youchun;Ren, Qifang;Fang, Hui;Zhang, Qicai;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.25 no.11
    • /
    • pp.590-597
    • /
    • 2015
  • In this article, poly methyl triethoxy silane was compounded with an inorganic waterproof admixture at a certain ratio to improve the performance of gypsum products; a new type of high-efficiency compound water-proofing additive was also investigated. Furthermore, the waterproof mechanism and the various properties on the hardened gypsum plaster were investigated in detail by XRD and SEM. The results show that the intenerate coefficient of gypsum plaster increased to more than 0.9; the water absorbing rate decreased to less than 10 %. Both the bending strength and the compressive strength of gypsum plaster increased by various degrees. The intenerate coefficient reached a maximum value of 0.73 and the strength of the samples showed almost no change when 5% cement alone was added. In this new type of the high-efficiency compound with waterproof additive, the optimal technological parameters for formulas were obtained to be: 5% cement, 18 % mineral powder, and 0.8% poly methyl triethoxy silane, to compound gypsum plaster. Meanwhile, the production of high performance gypsum as a building material has become possible.

Development of Energy Optimized Geometry Using BIM for Super Tall Office Building in Early Design Stages (BIM을 이용한 건축물 초기 디자인 단계에서 초고층 업무용 건물의 최적 에너지 형태개발)

  • Ryu, Han-Soo;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.83-91
    • /
    • 2011
  • There are many researches to make low-energy building. Lots of them focus on facility systems and insulation performance of building materials. However, not only systematic solutions but also approaches in early design stages are important to reduce energy consumption. Using BIM(Building Information Modelling) is considered as an effective and efficient way to simulate building energy and decide alternatives than traditional energy simulation because BIM based energy simulation makes to reduce much time for energy modeling. This study focuses on development of optimized geometry for super tall office buildings in Seoul, Korea. Specifically, length to width ratio and building orientation are main topics of this study because these two topics are the most basic and preceding factors deciding mass design. In this study, Revit MEP 2011 and Ecotect Analysis 2011 are used to make case models and calculate energy load in early design stages. Energy properties of material abide by Korean Standards for Energy Conservation in Building, Korean Guideline for Energy Conservation in Public Office and ASHRAE Standard in USA. This study presents best length to width ratio of plan and optimized orientation by evaluating the case models. Furthermore, this study suggests what should be considered for each case to decrease energy load.

The Advanced Case Study for Investigation on Application of BIPV on Tall Building (초고층빌딩의 BIPV 적용성 검토를 위한 선진 사례 조사)

  • Lee, Jong-Min;Seok, Ho-Tae;Yang, Jeong-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.155-160
    • /
    • 2009
  • The increasingly high prices for oil, the exhaustion of fossil fuels as well as concern about global warming are driving rapid growth of alternative sources of energy in the world. The active solution for global environment and exhaustion of energy sources is to develop and popularize the technologies to use natural energy such as sunlight, wind, and water. PV(Photovoltaic) modules are efficient devices that has been considered a logical material for use in buildings. Recent advanced BIPV(Building Integrated PV) technology have rapidly made PVs suitable for direct integration into construction in the world. Recently, building has been higher and higher. Tall buildings have many advantages for BIPV such as wide facade area and no shading effect by the surrounding buildings. However. BIPV has not been applied for tall building facade yet. Therefore, the purpose of the research is to develop suitable BIPV for tall buildings and to put these technologies to practical use. Therefore, the purpose of the study is to investigate unification of BIPV to curtain wall to apply BIPV on tall building through research into advanced application of overseas BIPV cases.

  • PDF

A Comparative Study of the Kiwarisho and Korea Material Proportion - about palace of building frame in three-bay Buddhist halls - (일본 키와리쇼와 한국의 부재비례 비교연구 - 3칸불당의 축부를 중심으로 -)

  • Kim, Byung-jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.59-67
    • /
    • 2018
  • In a state where ancient buildings was left a lot in the case of Korea, many parts do not remain the documentation, and there is a Kiwarisho lot in Japan, however, the present methods and tree split does not exist in the Korea. However, it is impossible to make a perfect building without splitting exact member when making a building. Thus will not be revealed simply by presumption that there is a similar way to wood comparatively far in Korea. Without a comparison of building dimensions and Korea calculation dimensions Kiwarisho In the first study about the proportionality of Korea, I do not know until now, other studies of the following documents which house a high approximation ratio and member size of Korea consider reason to have is impossible. View compared with respect to the axis of the building in the early stages of research first. In the case of Japan and Korea to form a tree frames in basic form that form the building, the shaft portion is easy to understand and easy compared in common is at most the shaft portion.

An Energy Performance Comparison of University Lecture Facilities for Energy Saving Building Design (에너지 절약형 건축물 설계를 위한 대학 강의동 형태별 에너지 성능 비교에 관한 연구)

  • Kim, Tae-Hoon;Seo, Ji-Hyo;Choo, Seung-Yeon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.105-112
    • /
    • 2018
  • Global environmental problems are growing, and the importance of buildings with high energy consumption has been emphasized. In Korea, the Ministry of Land, Transport and Maritime Affairs has been promoting the mandatory zero energy building since 2020, and guidelines related to the zero energy building have been developed. In addition, based on the "Energy-saving Design Criteria for Buildings" of the "Green Building Promotion Act" in Korea, the standards for energy-saving design are specified and the energy saving plan is written. Besides, the 'Energy-saving construction standards for eco-friendly houses' also specify insulation, machinery, equipment, and sunshade. Also, there is little consideration about the cost such as construction cost and material cost which should be considered important in the construction stage. Therefore, this study aims at analysis of building type and energy performance versus materials for energy saving building design considering energy performance in planning aspect of initial design stage. In this study, because the variables can not be neglected in this study, it is selected as the lecture facility of the 'K' university campus building which can consider the remaining factors except the passive design element as the control variable, Energy performance analysis.

Parametric Analysis of Building Energy Impact of Semi-transparent PV (STPV의 건물 에너지 성능에 대한 파라메트릭 분석)

  • Kwak, In-Kyu;Mun, Sun-Hye;Huh, Jung-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.35-42
    • /
    • 2018
  • Semi-transparent Photovoltaics (STPV) works as an exterior material replacing windows as well as functioning as a electricity generator. As a result, it also affects the building's heating, cooling and lighting loads. In this study, we used the concept of Net Electricity Benefit(NEB) to conduct a parametric analysis of building energy impact of STPV. The NEB of STPV is from $-1kWh/m^2$ to $6kWh/m^2$. Since NEB represents the amount of energy increase or decrease when STPV is applied compared to the standard window, a value of 0 or less means that the demand for building energy can be increased rather than applying a general window having high thermal performance and high visible light transmittance value. Therefore, it is necessary to perform a comprehensive performance evaluation considering both the performance evaluation based on the existing power generation performance and the influence on the building energy.

A STUDY ON THE SAFETY INFORMATION SYSTEM TO PREVENT HAZARD OF BUILDING CONSTRUCTION

  • Han-Min Lee;Seong-Seok Go;Hyuk Song;Hyun-Chul Lee
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.1048-1052
    • /
    • 2005
  • In Korean cases, the occupation of building construction is below 10% of the total industry workers but from a accident rate point of view, it is a risk serious industry and it's hazard is very considerable which accident rate is up to 30% of the total industry workers. The reason of high accident rate of the building construction is its own characteristic, hazard of the work in which is implicated and the shortage of safety counter plan and information, so it is most required to the building construction that educating, training, short and long period approaching to prevent the hazard. The safety information of building construction which is related to safety accident is divided into human and material such as hazard, work situation, cause and counter plan. The existing hazard cases imply all of the information about the work type and work progress of the building construction, so if the research of the every fact is well accomplished, we can obtain the useful information and prevent the hazard of building construction. From this point of view, the emphasis of this study is based on analyzing the cause of hazard first, suggesting the safety information each part of work type and work progress second, and finally making the all existing hazard cases to the Data Base and developing the safety information system.

  • PDF

Multi-Layered Shell Model and Seismic Limit States of a Containment Building in Nuclear Power Plant Considering Deterioration and Voids (열화 및 공극을 고려한 원전 격납건물의 다층쉘요소모델과 내진성능 한계상태)

  • Nam, Hyeonung;Hong, Kee-Jeung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.223-231
    • /
    • 2024
  • For the OPR1000, a standard power plant in Korea, an analytical model of the containment building considering voids and deterioration was built with multilayer shell elements. Voids were placed in the vulnerable parts of the analysis model, and the deterioration effects of concrete and rebar were reflected in the material model. To check the impact of voids and deterioration on the seismic performance of the containment building, iterative push-over analysis was performed on four cases of the analytical model with and without voids and deterioration. It was found that the effect of voids with a volume ratio of 0.6% on the seismic performance of the containment building was insignificant. The effect of strength reduction and cross-sectional area loss of reinforcement due to deterioration and the impact of strength increase of concrete due to long-term hardening offset each other, resulting in a slight increase in the lateral resistance of the containment building. To determine the limit state that adequately represents the seismic performance of the containment building considering voids and deterioration, the Ogaki shear strength equation, ASCE 43-05 low shear wall allowable lateral displacement ratio, and JEAC 4601 shear strain limit were compared and examined with the analytically derived failure point (ultimate point) in this study.

Experimental Study on Long-term Characteristics of Sprayable Waterproofing Membrane (차수용 박층 멤브레인의 장기 성능 변화에 관한 실험 연구)

  • Choi, Soon-Wook;Kim, Jintae;Choi, Myung-Sik;Chang, Soo-Ho;Kang, Tae-Ho;Lee, Chulho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.15-23
    • /
    • 2019
  • The sprayable waterproofing membrane is a recently introduced material in the civil engineering field, and is a material that sprays and attaches a single phase or two phase powder or liquid material to a surface to be covered using a pump and nozzle. Although the material properties are gradually reported through researches, there is a lack of studies on long-term performance compared to concrete materials used with the membranes. In this study, the long-term performance of materials was estimated using the Arrhenius equation. The temperature conditions used in this study were 65℃, 80℃ and 95℃, and the temperature was maintained with the membrane attached to the concrete block for long-term behavior. Then the membranes were tested for tensile strength and adhesion strength in the order of 30, 90, 150, 200, and 300 days. The long-term performance of the material was determined from a long-term perspective by estimating the activation energy by the Arrhenius equation. Consequently, the time to reach 50% of the performance standard could be estimated by long-term test.