• Title/Summary/Keyword: Building Lighting

Search Result 311, Processing Time 0.03 seconds

An Analysis of Daylighting Performance of Light Shelf in Office Building (사무소 건물에서 광선반의 채광성능 분석)

  • Park, Byung-Il;Yang, In-Ho;No, Mi-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study is to present the design guideline for an effective application of light shelf in office building. For this, the computer simulation using Daylighting System of 3Ds Studio Max was performed, and the optimal values related to design factors such as a depth, a surface reflectance and a installation angle of light shelf were obtained. Then daylighting performance of light shelf using the optimal values was analyzed, and the simulation results show that the installation of the optimal light shelf can improve a indoor lighting environment in office building.

A Study on quantity using lighting power of building in design stage (설계단계에서의 건축물 조명전력 사용량 조사 연구)

  • Min, Dae-Sik;Lee, Min-Uk;Oh, Hye-Young;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.183-186
    • /
    • 2007
  • 본 연구에서는 건축물 설계 시 조명전력 사용량 실태 조사 및 국내 조명전력 절감정책 과 외국에서 적용하고 있는 조명전력 허용기준의 적용사례와 국내 건물 중 사무실빌딩에서의 조명전력사용 실태를 조사 분석하여 향후 국내 조명전력허용기준을 적용하기 위한 선결과제 및 필요성을 제시하였다.

  • PDF

A Study on the improvement of working condition in the downtown Underground construction - Focused on the Ventilation and Lighting - (지하건설공사의 작업환경 개선에 관한 연구 -환기와 조명을 중심으로-)

  • 고성석;안홍섭
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.2
    • /
    • pp.119-132
    • /
    • 1997
  • According to the construction environmental changes due to the trend of large scale and complicated building construction, many construction methods(such as : TOPDOWN )are more often used. However, it is pointed out that occupational pulmonary diseases, reduction of the machinery lifetime and productivity caused to be narrow visual field and collision between the workers. Therefore, this study is mainly dealing with the views of productivity and safety improvement in order to improve work efficiency and to insure the safety in underground construction environment.

  • PDF

A Study on the BEMS Installation and performance Evaluation Method for Energy Monitoring(Measuring) of New Building (신축건물 에너지효율관리를 위한 환경 및 에너지모니터링(계측) 방법론)

  • Kwon, Won Jung;Yoon, Ji Hye;Kwon, Dong Myung
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.32-48
    • /
    • 2018
  • Monitoring of energy use should be a priority in order to efficiently manage building energy use. Energy use in buildings can be managed by dividing them into energy sources, uses, and ZONE. By energy source, electricity, gas, fuel, and district heating are supplied to run the building's facilities. The purpose can be divided into five main applications, including cooling, heating, lighting, hot water and ventilation, but not many elevators and electric heaters that are difficult to include in the five applications are classified. ZONE Star refers to the comparison or separate management of areas for which the purpose of the building is similar or different. In addition, energy efficiency management requires control of the temperature, humidity, and people who will be measuring energy in the building, and the recent problem of fine dust should directly affect the ventilation of the building.

The Field Survey of Indoor Environment of the Office Building (오피스 건물의 실내 환경 실태 조사)

  • Yang, Young Kwon;Kang, In Sung;Chung, Min Hee;Moon, Jin Woo;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2016
  • Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms.

A proposal of total energy operating system development using spatial information visualization and energy monitoring - Case study on design of total operation system in Sejong city - (건물 에너지 모니터링과 공간정보 시각화를 이용한 에너지 통합 운영시스템 개발 방안 제안 - 세종시 첫마을 공공건물을 대상으로 한 시스템 구축 사례 -)

  • Kwon, KeeJung;Lee, DongHwan;Cha, KiChun;Park, SeungHee
    • Journal of KIBIM
    • /
    • v.4 no.1
    • /
    • pp.8-12
    • /
    • 2014
  • This research and project is going on the Korean government. The objective of project is that developing total energy management solution. So, this paper is going to introduce a proposal that energy total operating system development using spatial information visualization and energy monitoring. It could efficiently operate the building energy wirelessly controling cooling/heating, lighting, air-conditioning and geothermal system. The metering data is collected to total database. The data is linked to BAS gateway, which is connected the device by the standard protocol.

How Shape of a Courtyard Affects Building's Interior Environment (중정 공간의 형태가 건물의 실내환경에 미치는 영향)

  • Jeon, Hyung-Woo;Byun, Jun-Hyuk;Seo, Hyun Jeong;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.4
    • /
    • pp.297-303
    • /
    • 2014
  • Currently, we usually do our activities inside of the buildings, so we don't often get enough of the direct sunlight, which could cause health problems. There was a recent move to solve this issue by adding a courtyard to new constructions. This research's goals are to determine how much of rays of the sun get into the building, if the natural lighting could be used as a light for the interior. With these, we may see the outcomes of mental revitalization for the people and reduces the consumption of the energy. Also, we try to analyze the temperature and the humidity of the inside, depends on the shape of the courthouse.

  • PDF

Analysis on Luminous Environment and Subjective Image of Two Different Commercial Streets at Night - Focused on View Point of Pedestrian - (야간상업가로의 조명물리량 및 이미지 분석 - 보행자 시점을 기준으로 -)

  • Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.31-38
    • /
    • 2007
  • Streetscape plays on important role in urban cities. Characteristics of streets is basically defined by the building facade, signs, plants and paving during the daytime. However at night, street receives a new appearance due to the shop light from the buildings, exterior lightings, signboards and street light, and it creates most of the image of the streets. This study aims to analyze the luminous environment and its subjective image of two different pedestrian's commercial streets. Insa-dong street and Myungdong street were chosen for the study. Horizontal illuminance and luminance on building surface, advertisement billboards and pedestrian road were measured. Thirty students were asked to rate the five scaled questionnaire on their subjective images of the streets. Statistical analysis including profile, correlation and T-test are conducted and some findings are discussed

Validation and Development of Artificial Sky Dome Facilities with a Heliodon (인공 천공돔과 헬리오돈의 개발 및 성능실험 사례 연구)

  • Kim, Jeong-Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.21-29
    • /
    • 2003
  • Scale model measurements should be conducted under an actual sky or in a simulated sky where conditions can be held constant. A number of successful attempts have been made to develop artificial sky domes with man-made sun emulators. With reference to formerly-developed examples, sky simulator facility has recently been activated in oder to provide desirable sky conditions for teaching and studies. The structure is a 6m-diameter dome and promises to set various condition for energy related and lighting research activities. The sky dome is also equipped a heliodon, the tilt table, to facilitate additive direct sun impact under clear skies. Shading studies, using scale models with the heliodon, reveal how a building's design blocks or permits light's passage to the interior; solar access studies, and tests of the reflection and transmittance characteristics of new daylighting technologies. The design and construction specification and the initial operating experience with a building configuration are reported.

A Performance Study on Passive Solar School Buildings with Sun Space (온실형 자연형 태양열 학교교사의 성능 분석 연구)

  • Lim, S.H.;Jeon, H.S.;Auh, P.C.
    • Solar Energy
    • /
    • v.9 no.1
    • /
    • pp.36-42
    • /
    • 1989
  • Following the oil crisis in 1979, there have been surge of movements by the government in Korea to conserve petroleum-based energy in every sector of society. One of these movements was the application of passive solar technologies into the construction of school buildings. Various passive designs are developed paying special regard to architectural and climatic factors. This paper is related to the application of the passive solar technology to elementary school buildings. It is proposed to place the hallway on the south side of the building to improve the thermal performance as well as indoor lighting effects. The cases have been compared with those of the existing school buildings where substantial improvements are noted. Finally, standard drawings are prepared in detail to promote the application of this passive solar technology in practical school building.

  • PDF