• Title/Summary/Keyword: Building Layer

검색결과 807건 처리시간 0.023초

BIM 기반 에너지성능분석을 통한 공동주택의 주동 설계 전략개발 - 주동타입 및 층수 변화를 중심으로 - (Multi-Family Housing Block Design Strategy Development by BIM-based Energy Performance Analysis - focusing on the Block Types and the Variations in Stories -)

  • 전재홍;박혜진;이권형;추승연
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.3-11
    • /
    • 2018
  • Korea has achieved a rapid economic development and with the increase in population and national income and the expansion of social and economic activities, energy consumption has rapidly increased too. Energy consumption per head has constantly increased and currently, power consumption per head is 7.5 times bigger than in 1985. Buildings occupy 25% of total energy consumption and especially, 50% of total energy is consumed for heating and cooling. In this situation, multi-family housing, which has constantly been increased, has an energy saving rate of 1.9%, which is the lowest level and this makes the government's energy policy for sustainable energy system development useless. Besides, energy consumption leads to secondary problems, such as air, water and marine pollution and heat pollution and wastewater/drainage and the increased use of fossil fuel is a fundamental reason for ozone layer destruction and global warming. Therefore, efficient energy consumption plans are required. This study aims to analyze energy performance in each block type of high-rise and diversified multi-family housing that accounts for 60% of all the housing forms, depending on the variations in stories through BIM-based energy simulation. For this study, four representative block types were selected, based on the multi-family floor plan, which is certified for energy performance evaluation and they were applied to the floor plan of a multi-family house that is scheduled to be built. Then BIM modeling was conducted from the fifth story to the 40th story at an intervals of 5 stories and based on the finding, energy characteristics of each block type and energy performance depending on the variations in stories were analyzed. It is considered that this would serve as objective data for block type and block story decision of energy performance-based multi-family housing.

기존 2층 피복 테트라포드 상부에 추가 거치되는 피복재(테트라포드)의 안정계수: 정적거치 조건 (Stability Number of Additionally Placed Armor Unit (Tetrapod) Covered on Existing Two-Layered Tetrapod Rubble Mound Structures: Pattern Placing Condition)

  • 김영택;이종인
    • 한국해안·해양공학회논문집
    • /
    • 제32권6호
    • /
    • pp.516-523
    • /
    • 2020
  • 항만구조물의 노후화가 가속화되면서 상향된 설계파 조건에 대응하기 위한 연구가 필요한 상황이다. 특히 피복재가 거치되는 경사식구조물의 경우, 상향된 설계파고에 안정중량을 확보하기 위해서는 피복재의 중량 증가가 필요하다. 그렇지만 그와 관련된 연구는 진행된 사례가 없다. 본 연구에서는 기존 피복재가 거치된 경사식구조물에 추가 피복재를 거치하는 경우, 추가 피복재의 안정중량 산정을 위한 수리모형실험을 수행하였다. 피복재로는 콘크리트 이형블록인 테트라포드를 적용하였다. 실험결과에 의하면 비월파 조건에서 기존 피복재(테트라포드)가 정적 거치이고 사면경사의 변화가 거의 없는 경우 실험조건 내에서 추가피복재(테트라포드)의 안정계수(Kd)는 일반적인 테트라포드 안정계수(Kd = 8)에 비하여 주기별로 차이가 있으나 최대 10% 증가하는 것으로 나타났다.

유입 공기의 배출 성능 개선방안에 관한 연구 (A Study on the Performance Improvement Plan of Inflowing Air Emission)

  • 이혜영
    • 한국재난정보학회 논문집
    • /
    • 제18권2호
    • /
    • pp.241-251
    • /
    • 2022
  • 연구목적: 고층 건물 화재시 제연구역이 효과적으로 보호되지 않으면 수직피난경로에 연기나 화염이 유입되어 대피가 어려워진다. 국가화재안전기준에서는 제연구역에 차압 및 방연풍속을 공급하여 능동적으로 연기 유입을 억제하고, 제연구역으로부터 옥내로 유입되는 공기는 옥외로 배출되도록 하고 있다. 본 연구는 유입 공기의 배출로 인한 문제점을 확인하고 성능개선 방안에 대하여 알아보고자 하였다. 연구방법: CONTAM 프로그램을 사용하여 기본조건과 변경조건으로 시뮬레이션을 수행하였다. 연구결과: 밀폐된 복도에서 유입 공기가 배출되면 제연구역에서 과압이 발생하여 개방력을 초과하였고 유입공기가 배출되지 않는 층 에서는 방연풍속이 미달하였다. 결론: "차압 배출댐퍼" 적용, 배출댐퍼 2개층 동시 개방, 복도와 옥외 사이 자동식 창문 설치로 유입공기의 배출 성능이 개선되었다.

Flexural response of steel beams strengthened by fibre-reinforced plastic plate and fire retardant coating at elevated temperatures

  • Ahmed, Alim Al Ayub;Kharnoob, Majid M.;Akhmadeev, Ravil;Sevbitov, Andrei;Jalil, Abduladheem Turki;Kadhim, Mustafa M.;Hansh, Zahra J.;Mustafa, Yasser Fakri;Akhmadullina, Irina
    • Structural Engineering and Mechanics
    • /
    • 제83권4호
    • /
    • pp.551-561
    • /
    • 2022
  • In this paper, the effect of fire conditions according to ISO 834 standard on the behavior of carbon fibre-reinforced plastic (CFRP) reinforced steel beams coated with gypsum-based mortar has been investigated numerically. To study the efficiency of these beams, 3D coupled temperature-displacement finite element analyzes have been conducted. Mechanical and thermal characteristics of three different parts of composite beams, i.e., steel, CFRP plate, and fireproof coating, were considered as a function of temperature. The interaction between steel and CFRP plate has been simulated employing the adhesion model. The effect of temperature, CFRP plate reinforcement, and the fireproof coating thickness on the deformation of the beams have been analyzed. The results showed that within the first 120 min of fire exposure, increasing the thickness of the fireproof coating from 1 mm to 10 mm reduced the maximum temperature of the outer surface of the steel beam from 380℃ to 270℃. This increase in the thickness of the fireproof layer decreased the rate of growth in the temperature of the steel beam by approximately 30%. Besides excellent thermal resistance and gypsum-based mortar, the studied fireproof coating method could provide better fire resistance for steel structures and thus can be applied to building materials.

지반의 동상력과 구조물의 피해대책 (Frost Heave Force of Ground and Countermeasure for Damage of Structures)

  • 예대호;영목휘지;김영수
    • 한국지반공학회논문집
    • /
    • 제23권5호
    • /
    • pp.43-51
    • /
    • 2007
  • 동결작용은 빌딩, 구조물, 도로, 철도 그리고 공공시설관로에 엄청난 손상을 일으킬 것이다. 자연지반의 동상에 대한 연구는 과거에 많이 수행되었다. 근래에는 사회기반시설 유지의 발전과 함께 각종구조물의 복잡화로 인하여 동상대책에 대한 관심이 집중되고 있다. 본 연구에서는 구조물에 작용하는 자연지반의 동상력을 정량적으로 파악하는 것을 목적으로 하였다. 지표면에 설치한 원형강판에 작용하는 동상력이 현장시험에서 측정되었다. 동결면에서 발생하는 동상력은 동결된 토층을 거쳐 구조물에 전달된다. 또한 다단앵커로 보강된 옹벽이 현장에 설치되고 옹벽에 작용하는 동결선과 동상압 등이 측정되었다. 최종적으로 동결면의 위치와 형상이 수치해석수법을 이용하여 추정되었고 치환 범위를 결정하는 설계수법이 토질정보와 기상정보에 따라 제안되었다.

내화피복을 적용한 강합성보의 구조화재해석 (Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials)

  • 강준원;강문수;윤혜진
    • 한국전산구조공학회논문집
    • /
    • 제36권2호
    • /
    • pp.137-145
    • /
    • 2023
  • 이 논문은 정적 재하상태에 있는 무피복 강합성보와 내화피복을 적용한 강합성보를 대상으로 화재 시 내부 온도 및 수직처짐에 대한 내화피복의 영향을 평가한 결과를 제시한다. 열응력해석을 위한 화재하중으로는 American Society for Testing and Materials E119의 표준화재곡선을 사용했으며, 강재거더 표면에 부착하는 내화재료의 방화효과를 구현하기 위해 외기에서 강합성보로 전달되는 열의 전달계수를 감소시켰다. 실규모 무피복 강합성보에 대한 구조화재실험에서 내부 온도분포와 수직처짐을 측정하였고 실험 결과와의 비교를 통해 비선형 구조화재해석 결과의 타당성을 검증하였다. 내화피복이 적용된 강합성보의 구조화재해석 결과로부터 강재거더 표면에 내화재를 적용할 경우 동일 화재 조건에서 무피복 강합성보에 비해 내부 온도와 수직처짐이 감소함을 알 수 있었다. 또한 열전달계수의 변화에 따른 열응력 응답으로부터 화재 시 강합성보의 온도 및 구조거동에 대한 내화피복의 영향을 제시하였다.

Ensembles of neural network with stochastic optimization algorithms in predicting concrete tensile strength

  • Hu, Juan;Dong, Fenghui;Qiu, Yiqi;Xi, Lei;Majdi, Ali;Ali, H. Elhosiny
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.205-218
    • /
    • 2022
  • Proper calculation of splitting tensile strength (STS) of concrete has been a crucial task, due to the wide use of concrete in the construction sector. Following many recent studies that have proposed various predictive models for this aim, this study suggests and tests the functionality of three hybrid models in predicting the STS from the characteristics of the mixture components including cement compressive strength, cement tensile strength, curing age, the maximum size of the crushed stone, stone powder content, sand fine modulus, water to binder ratio, and the ratio of sand. A multi-layer perceptron (MLP) neural network incorporates invasive weed optimization (IWO), cuttlefish optimization algorithm (CFOA), and electrostatic discharge algorithm (ESDA) which are among the newest optimization techniques. A dataset from the earlier literature is used for exploring and extrapolating the STS behavior. The results acquired from several accuracy criteria demonstrated a nice learning capability for all three hybrid models viz. IWO-MLP, CFOA-MLP, and ESDA-MLP. Also in the prediction phase, the prediction products were in a promising agreement (above 88%) with experimental results. However, a comparative look revealed the ESDA-MLP as the most accurate predictor. Considering mean absolute percentage error (MAPE) index, the error of ESDA-MLP was 9.05%, while the corresponding value for IWO-MLP and CFOA-MLP was 9.17 and 13.97%, respectively. Since the combination of MLP and ESDA can be an effective tool for optimizing the concrete mixture toward a desirable STS, the last part of this study is dedicated to extracting a predictive formula from this model.

비선형 유체-구조물-지반 상호작용 고려한 원통형 액체저장탱크의 지진응답해석 (Earthquake Response Analysis of Cylindrical Liquid-Storage Tanks Considering Nonlinear Fluid-Structure Soil Interactions)

  • 이진호;조정래
    • 한국전산구조공학회논문집
    • /
    • 제37권2호
    • /
    • pp.133-141
    • /
    • 2024
  • 유체-구조물-지반 상호작용을 고려한 액체저장탱크의 유한요소 모형을 제시하고, 비선형 지진응답 해석기법을 정식화한다. 탱크 구조물은 기하 및 재료 비선형 거동을 고려할 수 있는 쉘 요소로 모델링한다. 유체의 거동은 acoustic 요소로 구현하고, interface 요소를 사용하여 구조물과 결합한다. 지반-구조물 상호작용을 고려하기 위해 지반의 근역과 원역을 각각 solid 요소와 perfectly matched discrete layer로 모델링한다. 예제 20만 kl급 액체저장탱크의 지진취약도 해석에 적용하여, 유연한 지반에 구조물이 놓인 경우 부지에서의 암반노두운동의 증폭 및 필터링으로 인해 지진취약도의 중앙값과 대수 표준편차가 감소하는 것을 관찰할 수 있다.

Predicting restraining effects in CFS channels: A machine learning approach

  • Seyed Mohammad Mojtabaei;Rasoul Khandan;Iman Hajirasouliha
    • Steel and Composite Structures
    • /
    • 제51권4호
    • /
    • pp.441-456
    • /
    • 2024
  • This paper aims to develop Machine Learning (ML) algorithms to predict the buckling resistance of cold-formed steel (CFS) channels with restrained flanges, widely used in typical CFS sheathed wall panels, and provide practical design tools for engineers. The effects of cross-sectional restraints were first evaluated on the elastic buckling behaviour of CFS channels subjected to pure axial compressive load or bending moment. Feedforward multi-layer Artificial Neural Networks (ANNs) were then trained on different datasets comprising CFS channels with various dimensions and properties, plate thicknesses, and restraining conditions on one or two flanges, while the elastic distortional buckling resistance of the elements were determined according to the Finite Strip Method (FSM). To develop less biased networks and ensure that every observation from the original dataset has the chance of appearing in the training and test set, a K-fold cross-validation technique was implemented. In addition, the hyperparameters of the ANNs were tuned using a grid search technique to provide ANNs with optimum performances. The results demonstrated that the trained ANNs were able to predict the elastic distortional buckling resistance of CFS flange-restrained elements with an average accuracy of 99% in terms of coefficient of determination. The developed models were then used to propose a simple ANN-based design formula for the prediction of the elastic distortional buckling stress of CFS flange-restrained elements. Finally, the proposed formula was further evaluated on a separate set of unseen data to ensure its accuracy for practical applications.

Study on response of a new double story isolated structure under earthquakes

  • Hang Shan;Dewen Liu;Zhiang Li;Fusong Peng;Tiange Zhao;Yiran Huo;Kai Liu;Min Lei
    • Earthquakes and Structures
    • /
    • 제27권1호
    • /
    • pp.17-29
    • /
    • 2024
  • The traditional double story isolated structure is a derivative of the base isolated and inter-story isolated structures, while the new double story isolated structure represents a novel variation derived from the traditional double story isolated structure. In order to investigate the seismic response of the new double story isolated structure, a comprehensive structural model was developed. Concurrently, models for the basic fixed, base isolated, inter-story isolated, and traditional double story isolated structures were also established for comparative analysis. The nonlinear dynamic time-history response of the new double story isolated structure under rare earthquake excitations was analyzed. The findings of the study reveal that, in comparison to the basic fixed structure, the new double story isolated structure exhibits superior performance across all evaluated aspects. Furthermore, when compared to the base isolated and inter-story isolated structures, the new double story isolated structure demonstrates significant reductions in inter-story shear force, top acceleration, and inter-frame displacement. The horizontal displacement of the new double story isolated structure is primarily localized within the two isolation layers, effectively dissipating the majority of input seismic energy. In contrast to the traditional double story isolated structure, the new design minimizes displacements within the inter-isolation layer situated in the central part of the frame, as well as mitigates the overturning forces acting on the lower frame column. Consequently, this design ensures the structural integrity of the core tube, thereby preventing potential collapse and structural damage.