• 제목/요약/키워드: Building Layer

검색결과 807건 처리시간 0.025초

Population Allocation at the Building level for Micro-level Urban Simulation: A Case of Jeonju, Korea

  • Kim, Dohyung;Cho, Dongin
    • Asian Journal of Innovation and Policy
    • /
    • 제9권2호
    • /
    • pp.223-239
    • /
    • 2020
  • It is important for urban planners and policy makers to understand complex, diverse urban demands and social structure, but this is not easy due to lack of data that represents the dynamics of residents at micro-geographical level. This paper explores how to create population data at at a micro-level by allocating population data to building. It attempted to allocate population data stored in a grid layer (100 meters by 100 meters) into a building footprint layer that represents the appearance of physical buildings. For the allocation, this paper describes a systemic approach that classifies grid cells into five prototypical patterns based on the composition of residential building types in a grid cell. This approach enhances allocation accuracy by accommodating heterogeneity of urban space rather than relying on the assumption of uniform spatial homogeneity of populations within an aerial unit. Unlike the methods that disaggregate population data to the parcel, this approach is more applicable to Asian cities where large multifamily residential parcels are common. However, it should be noted that this paper does not demonstrate the validity of the allocated population since there is a lack of the actual data available to be compared with the current estimated population. In the case of water and electricity, the data is already attached to an individual address, and hence, it can be considered to the purpose of the validation for the allocation. By doing so, it will be possible to identify innovative methods that create a population distribution dataset representing the comprehensive and dynamic nature of the population at the micro geographical level.

도심 건축물 그림자효과에 의한 다중 반사도 변화와 도시지표면 열수지에 미치는 영향 (Multiple Albedo Variation Caused by the Shadow Effect of Urban Building and Its Impacts on the Urban Surface Heat Budget)

  • 이순환;안지숙;김상우;김해동
    • 한국지구과학회지
    • /
    • 제31권7호
    • /
    • pp.738-748
    • /
    • 2010
  • 도심지 빌딩에 의한 그림자가 대기경계층에 미치는 영향을 파악하기위하여 위성자료 분석과 수치실험을 실시하였다. 연구에 사용된 위성은 한국다목적위성(KOMSAT-2)의 가시자료이며, 수치모형은 다중반사도 계산을 위한 반사도 계산모형과 지표면 열수지를 계산하기 위한 오레건주립대학교 경계층 모형의 2가지이다. 위성자료 분석에서 고층빌딩이 밀집한 지역은 그렇지 못한 지역에 비하여 반사도가 최대 17% 낮게 산정되었다. 이는 건물의 그림자가 원인으로 작용한다. 그리고 반사도의 일변화는 태양고도에 따라 다르며, 정오에 가장 작은 값을 나타낸다. 건물 밀도가 높은 경우 지표면 온도가 $43.5^{\circ}C$까지 상승하는데 비하여 건물 밀도가 낮은 지역의 경우 지표면 온도는 $37.4^{\circ}C$까지 상승한다. 그러나 높은 빌딩에 따른 기계적 난류에 의하여 반사도에 의한 온도상승이 직접적으로 대기온도상승과 연결되지는 않는다.

면섬유가 보강된 폴리우레탄계 복합시트의 기초 물성 평가 (Evaluation on the Basic Properties of Polyurethane Composite Sheet Reinforced with Non-Woven Fabric)

  • 김지현;도승배;박정원;남기융;정철우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.238-239
    • /
    • 2017
  • Waterproofing is a very important process in terms of durability of buildings. The materials used for waterproofing work to protect the concrete structure from external deterioration factors. In particular, the waterproofing materials applied to the exterior of the concrete structure have various problems due to changes in the external environment and variables in the construction process. The waterproof layer is repeatedly dried and shrunk according to changes in the external moisture environment, and the surface may be deteriorated due to exposure to long-term sunlight. In the case of the roof waterproofing in the structure, the waterproof layer which does not have a sufficient curing period shows much swelling and floating phenomenon. These defects, such as swelling and lifting, account for most of the defects that occur in the waterproof layer of the concrete slabs. Generally, it is difficult to expect the same level of performance as the initial state even if the waterproofing work is repaired when a defect occurs. Therefore, it is possible to reduce the defects of the waterproof layer such as swelling and lifting by forming a waterproof layer which can be integrated with the concrete surface by using a polyurethane type waterproofing material having a relatively low defective ratio compared to other waterproofing materials. So in this study, the basic properties of polyurethane waterproof sheet reinforced with non-woven fabric are investigated in order to understand field applicability.

  • PDF

콘크리트와 도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구 (An Experimental Study of Water Vapor Pressure that occurs at the Interface of a Fluid-Applied Membrane and Concrete)

  • 고진수;김문희;이성복;신윤호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.147-150
    • /
    • 2006
  • Of the total defects that have occurred recently in the Korean construction market, over 30% are caused by the construction of defective waterproofing, and the phenomenon of air pockets in the waterproofing layer, which is caused by the concrete vapor pressure, is known to be the primary cause of defective waterproofing. Accordingly, in this study the theory about the relationship between water pressure and temperature as well as the damp-proofing volume of concrete and, then, the change of vapor pressure volume was measured and analyzed by making a test sample after spraying a dampness remover and a waterproofing material to a prepared test body. As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about $10^{\circ}C$, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about $0.3kgf/cm^2$ when the surface temperature of the waterproofing layer was raised up to about $80^{\circ}C$. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from $30^{\circ}C\;to\;35^{\circ}C,\;about\;0.1kgf/cm^2$ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from $35^{\circ}C\;to\;40^{\circ}C$, approximately $0.05kgf/cm^2$ of water vapor pressure was generated.

  • PDF

Hunt 해석해를 이용한 천부대수층 지하수 양수로 인한 하천수 감소 영향 분석 (Evaluation of stream depletion from groundwater pumping in shallow aquifer using the Hunt's analytical solution)

  • 이정우;정일문;김남원;홍성훈
    • 한국수자원학회논문집
    • /
    • 제49권11호
    • /
    • pp.923-930
    • /
    • 2016
  • 본 연구에서는 2층 누수대수층-하천 시스템에 관한 Hunt (2009)의 해석해를 이용하여 천부대수층 지하수 양수가 하천수량에 미치는 영향을 분석하였다. 대수층 및 하상의 수리특성 조건에 따라 총 2,187가지 경우의 수에 대해서 양수량 대비 하천수 감소량을 산정한 결과 하천고갈인자가 1,000-10,000 보다 큰 경우에 비교적 작은 값을 나타내었으며, 하천바닥층 수리전도도보다는 1, 2층간 반대수층의 수리전도도 크기에 상대적으로 민감한 반응을 보였다. 또한, Hunt (1999)의 해석해로 산정한 하천수 감소비에 비해 최대 0.3을 넘는 차이가 발생하는 등 1층의 하천고갈인자가 큰 경우에는 2층의 수리특성치에 큰 영향을 받는 것으로 분석되었다. 실제로 충주시에 위치한 임의의 천부지하수 관정에 적용하여 양수 경과시간에 따른 하천수 감소비를 산정한 결과 수일 내로 0.8을 초과하여 하천수에 미치는 영향이 단기간에 크게 발생하였으며, 또한 누수계수가 작고 천부대수층의 수리확산계수가 큰 지역에서는 하천-관정 이격거리가 하천수 감소량 크기를 결정하는데 지배적인 인자인 것으로 분석되었다.

건물의 영향을 고려한 이중배수체계기반 침수해석 (Analysis of Urban Inundation Considering Building Footprints Based on Dual-Drainage Scheme)

  • 이정영;진기호;하성룡
    • 한국지리정보학회지
    • /
    • 제17권4호
    • /
    • pp.40-51
    • /
    • 2014
  • 본 연구의 목적은 건물의 유무에 따른 도시지역의 침수특성을 이중배수체계기반의 2차원 침수 해석모형을 이용하여 각각 해석하고 해석 결과의 차이를 비교하는데 있다. 이를 위해 LiDAR 측량 기반 $1m{\times}1m$ 해상도의 표고모델과 표고모델 위에 건물의 외벽을 따라 지표수 유입을 억제하는 격자를 생성한 표고모델의 2가지 지형자료를 구축하였고, 2가지 지형조건을 2차원 침수해석모형의 입력 자료로 활용하기 위해 $10m{\times}10m$ 해상도로 re-sampling 하였다. 분석 결과, CCTV 영상에 의한 실측 침수심 자료와 모의값을 비교한 결과, 건물을 고려하지 않은 지형자료를 사용한 경우 침수심이 과소 산출되었으나, 건물을 고려한 경우에는 실측값과 근사하게 모의되었다. 침수심의 차이는 침수 가능 면적의 변화에 따라 침수체적이 변하게 되므로, 지표면으로 유출되는 수문량이 절대량으로 고정된다면 침수 가능영역이 큰 지형자료를 사용한 경우 침수심이 낮아지기 때문인 것으로 판단된다. 한편 침수흔적도와 비교한 침수면적은 두 지형자료 모두 큰 차이를 보이지 않았으나 근사하게 건물을 고려한 경우의 일치도가 높은 것으로 나타났다. 따라서 침수면적과 침수심의 두 가지를 종합적으로 고려한다면, 이중배수체계기반의 2차원 침수해석모형을 활용하여 도시유역의 침수해석을 수행하는 경우, 건물을 고려한 지형자료를 사용하는 것이 바람직하다고 판단된다.

멀티센서 데이터를 이용한 건물의 3차원 모델링 기법 개발 및 평가 (Developing and Valuating 3D Building Models Based on Multi Sensor Data (LiDAR, Digital Image and Digital Map))

  • 위광재;김은영;윤홍식;강인구
    • 한국측량학회지
    • /
    • 제25권1호
    • /
    • pp.19-30
    • /
    • 2007
  • 현실세계를 컴퓨터에 재현하기 위해서는 건물에 대한 3D 모델링 작업이 가장 필수적인 작업이다. 건물에 대한 3차원 모델링의 방법으로는 항공레이저측량을 통하여 획득된 고밀도 3차원 점 데이터를 기반으로 하여 1:1,000 수치지형도의 건물 레이어를 이용하는 방법과 LiDAR 데이터와 함께 취득되는 디지털 영상을 이용하는 방법으로 구분할 수 있는데 본 연구에서는 각각의 방법에 대하여 1:1,000 수치지형도 1도엽을 대상으로 건물에 대한 3차원 모델링 작업을 실시하여 작업방법을 개발하였으며, 효율성, 정확도 및 재현성를 정량적으로 평가 분석하였다. 연구 결과, 단순 건물의 경우에는 수치지형도와 LiDAR 데이터를 이용하는 것이 효율적인 것으로 나타났으며, 모양이 다양하고 복잡한 형태의 건물의 경우는 LiDAR 데이터와 디지털 영상을 이용하여 모델링 하는 것이 효과적임을 알 수 있었다. 또한 모델링된 정확도 평가 결과, LiDAR 데이터와 디지털 영상을 이용하여 건물에 대하여 3차원 모델링후, 수치지형도와 비교하였을 때, 수평위치가 ${\pm}50cm$ 이내인 것으로 나타났다. 따라서 건물에 대한 3차원 모델링 작업은 LiDAR 데이터와 수치지형도의 건물 레이어을 이용하여 효과적으로 수행 할 수 있을 것으로 판단이 되며 구축된 3차원 건물 모델링 데이터는 3D GIS. U-City, Telematics, Navigation, 가상현실 및 게임 등 다양한 분야의 디지털 콘텐츠로 활용할 수 있을 것이다.

BIPV 시스템을 위한 전이금속 산화물 다중층 컬러 유리 구현 기술 연구 (Transition Metal Oxide Multi-Layer Color Glass for Building Integrated Photovoltaic System)

  • 안현식;;장은정;김민회;이재현;최윤석
    • 전기전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.1128-1133
    • /
    • 2019
  • 이 논문에서는 전이 금속 산화물(TMO)층으로 구성된 다층 박막을 사용하는 BIPV(Building Integrated Photovoltaic) 시스템용 전면 컬러 유리를 제안하였다. 몰리브덴 산화물(MoO3) 및 텅스텐 산화물(WO3)은 굴절률 차이가 큰 계면을 형성하여 적절한 간섭효과를 얻을 수 있다. 단일 Thermal Evaporator 증착 방법을 통해 다층 박막을 제작함으로써 간단하고 빠르며 저렴한 제조 방법을 제안하였다. MoO3(60nm)/WO3(100nm) 다층 박막으로 90% 이상의 광 투과율을 갖는 자홍색 유리를 시연하였으며, 이 기술은 상용화된 BIPV 시스템에 유용할 것으로 기대된다.

지능형 빌딩을 위한 디지털 통합 전관 방송 시스템 개발 (Development of Integrated Public Address System for Intelligent Building)

  • 김정숙;송치원
    • 한국지능시스템학회논문지
    • /
    • 제21권2호
    • /
    • pp.212-217
    • /
    • 2011
  • 본 논문에서는 미래 지능형 빌딩 시스템에서 요구되는 다양한 상황을 인지할 수 있는 지능형 디지털 통합 전관 방송 시스템을 개발하였다. 화재와 재난과 같은 응급 상황이 발생할 때 울리는 경보음을 인식할 수 있으며, 실내 온도와 습도 및 환경 오염도와 같은 다양한 센서 출력을 전달 받아 지능적으로 상황에 맞는 대처 방안을 필요한 곳에 개별적으로 방송할 수 있는 지능형 디지털 통합 전관 방송 시스템을 개발하였다. 외부 입력, 마이크, CD와 MP3 및 라디오 기능 등을 일체형으로 통합하고 소형화한 디지털 전관 방송 시스템을 개발하고 있으며, 시스템이 중앙 집중 제어가 가능하도록 운용 MICOM을 개발하였다. 중앙 집중 제어를 수행하기 위해 운용 MICOM은 제어 계층, 처리 계층 및 사용자 인터페이스 계층인 3계층으로 구성된다.

업무용 빌딩의 피난 성능 검토에 관한 연구 (A Study on the Evacuation Performance Review for the Office Buildings)

  • 오혁진;백승태;김우석;이수경
    • 한국화재소방학회논문지
    • /
    • 제17권3호
    • /
    • pp.1-6
    • /
    • 2003
  • 본 연구에서는 특정의 업무용 건축물에 대해서 화재 및 피난 시나리오를 선정하여 FAST 3.1.7(전실화재 예측), SIMULEX 32-bit(피난시간의 예측), JASMINE 3.25d(특정시간까지의 연기 유동성 평가)등의 S/W를 이용하여 이를 평가했으며 그 결과는 다음과 같다. Scenario #1 결과, 화재실에서 전실화재가 발생하지 않았고, 층 피난시간은 25.2 sec로 나타났으며 이때까지의 FAST 3.1.7결과에서 연기층은 2.4m를 기록, 연기유동성 평가에서도 재실자들은 연기의 피해(가시거리, 독성)없이 피난이 완료될 것으로 나타났다. Scenario #2 결과, 화재실에서 6 min 33.2 sec에 전실화재가 발생했으며, 수계산에 의한 피난시간은 5 min 23sec로 나타났다. 본 대상건물에 대해서 선정한 Scenario #1, #2 모두 인명안전설계는 적정하게 설계되었다고 판단된다.