• Title/Summary/Keyword: Building Impact Analysis

Search Result 663, Processing Time 0.03 seconds

Environmental Impact Assessment at a School Building using Input-output Table - Focused on Elementary School in Gyeonggi-do - (산업연관분석법을 이용한 학교 건물에서의 환경영향평가 - 경기지역의 초등학교를 대상으로 -)

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: A lot of active researches have addressed the impact of a building on global environment, but most of the researches focus on a residential building and a large office building. Hereupon, this study assessed the impact on environment quantitatively through the analysis of input materials targeting a school building. Method:This study calculated embodied energy of input materials suggested in a construction statement on a school building using the input-output analysis. This study finally carried out environmental impact assessment by applying LCIA DB shown in the preceding researches to the calculated embodied energy. Result: The analysis result revealed that the environmental impact per unit area(/$m^2$) at a school building was $4.11E-02PE{\cdot}yr$, among which Construction was found to be $3.59E-02PE{\cdot}yr$, being analyzed to account for about 87% of the total environmental impact. Also, as a result of detailed environmental impact, the impact on global warming among the total environmental impact was analyzed to be high, accounting for about 76%.

The development and application of environmental impact assessment program for apartment building element based on building materials LCI DB (건축재료 LCI DB 기반의 공동주택 부위별 환경영향 평가 프로그램 개발 및 적용에 관한 연구)

  • Kim, Rak Hyun;Tae, Sung Ho;Kim, Ji Hoon;Lee, Jong Gun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.151-157
    • /
    • 2016
  • Purpose: The purpose of this study is to develop and apply an environmental impact assessment program for apartment building elements, based on the building materials of the LCI DB, which can link the LCA results of building materials and buildings. Method: For this purpose, a framework for building elements was established, and several building material combinations were developed. In addition, the LCA method for quantifying environmental load emissions from the building materials of each site was applied to establish an environmental impact database of the building materials of the LCI DB. Result: An environmental impact assessment program, based on a Microsoft Excel worksheet, was developed for apartment building elements. This program can link the environmental impact assessment of building materials and building units. To validate the program evaluation results that were obtained in this study, a comparative analysis was carried out using the results of existing evaluation methods. The error rate was estimated to be 5% for environmental impact assessment using existing evaluation methods.

Impact of Building Blocks on Inundation Level in Urban Drainage Area (지표 건물이 도시유역의 침수특성에 미치는 영향)

  • Lee, Jeong-Young;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.1
    • /
    • pp.99-107
    • /
    • 2013
  • This study is an impact assessment of building blocks on urban inundation depth and area. LiDAR data is used to generate two original data set in terms of DEM with $5{\times}5$ meter and building block elevation layer of the study drainage area in Cheongju and then the building block elevation layer is modified again to the mesh data with same size to DEM. Two-dimensional inundation analysis is carried out by applying 2D SWMM model. The inundation depth calculated by using the building block elevation layer shows higher reliability than the DEM. This is resulted from the building block interference to surface flow. In addition, the maximum flooded area by DEM is two times wider than the area by building block layer. In the case of the surface velocity, the difference of velocity is negligible in either DEM or building block case in the low building impact zone. However, If the impact of building on the surface velocity was increase, the gap of velocity was significant.

Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure (벽식구조 표준시험동에서 중량충격음장에 관한 연구)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF

Radiation Characteristics of Heavy-weight Floor Impact Sounds in a Standard Test Building (표준실험동에서 중량충격음의 방사 특성)

  • Yoo, Seung-Yup;Jeong, Yong;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.381-384
    • /
    • 2005
  • The purpose of this study is to develop a prediction model for evaluating heavy-weight floor impact sounds in a test building. Three rooms in the test building (slab thickness In and 240mm), which consist of frame concrete structures were tested and modeled. First, the SPL distribution in the receiving room was analyzed by measuring SPL at 90 positions using a bang machine. Then, a vibration model using finite element method is proposed considering the material properties and boundary conditions. In addition, the result of transient analysis was compared with field measurements using a standard heavy-weight impact source. Through a vibro-acoustic simulation program, an acoustic model evaluating the building elements (reflected wall, nor, window and door) was proposed. Finally, validation of the prediction model was conducted by vibro-acoustic analysis with field measurements of noise radiation characteristics in receiving rooms.

  • PDF

A Basic Study on Analysis of the Impact of Building Shape on Safety Accidents (건물의 형상이 안전사고에 미치는 영향분석에 관한 기초연구)

  • Son, Seunghyun;Kim, Ji-Myung;Ahn, Sungjin;Han, Bumjin;Na, Youngju;Kim, Taehui
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.27-28
    • /
    • 2022
  • There is a limit to preventing various types of safety accidents in advance at construction sites. Even for buildings of the same total floor area, it is expected that the more complex the building shape or the higher the number of floors, the higher the probability of a safety accident. Therefore, it is necessary to analyze the effect of the shape of a building on safety accidents using safety accident data generated during actual construction. The purpose of this study is to analyze the impact of building shape on safety accidents. As a result, the R2 value of shape factor and safety accident was 0.901, and the R2 value of construction difficulty and safety accident was 0.944. In the future, the results of this study will be used as basic data for improving safety management related systems.

  • PDF

Impact of Horizontal Global Solar Radiation Calculation Modelson Building Energy Performance Analysis Considering Solar Heat Gain Coefficient and Window-to-wall Ratio (수평면 전일사량 산출모델이 일사열취득계수 및 창면적비를 고려한 건물 에너지 성능분석에 미치는 영향)

  • Kim, Kee Han;Oh, John Kie-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.39-47
    • /
    • 2014
  • Solar applications analysis and building energy performance depend on the quality of the solar resource data available. Unfortunately, most of the weather stations do not measure solar radiation data in Korea, as a reason many researchers have studied different solar radiation estimation models and suggested to apply them to various locations in Korea. In addition, they also studied the impact of hourly global solar radiation on energy performance of an office building by comparing the simulated building energy consumptions using four different weather files, one using measured, and three estimated solar radiation from different models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM), and concluded that there was some impact on energy performance of the building due to the using different solar radiation models. However, the result cannot be applied to all other buildings since the simulated office building for that study only used limited building characteristics such as using fixed values of solar heat gain coefficient (SHGC) and window-to-wall ratio (WWR), which are significant parameters related to solar radiation that affect to the building energy consumptions. Therefore, there is a need to identify how the building energy consumption will be changed by varying these building parameters. In this study, the impact of one measured and three estimated global solar radiation on energy performance of the office building was conducted taking account of SHGC and WWR. As a result, it was identified that the impact of four different solar radiation data on energy performance of the office building was evident regardless SHGC and WWR changes, and concluded that the most suitable solar models was changed from the CRM/ZHM to the MRM as SHGC and WWR increases.

Impact of Green Building Rating System on an Apartment Housing CO2 Emission using Multiple Regression Analysis (다중 회귀 분석을 이용한 친환경 건축물 인증제도가 공동주택 CO2 발생량에 미치는 영향 분석)

  • Jung, Jung-Hee;Ryu, Hyeok-Jun;Lee, Jong-Hun;Kim, Ju-Hyung;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.111-112
    • /
    • 2013
  • Architecture has a large influence in the environment and human health. Therefore eco-friendly concept and sustainable development are important in Architectural field. This study aims to analyze impact of green building rating system on an apartment housing CO2 emission using multiple regression analysis. But in this result, green building rating system has no effect on CO2 emission. So, future study is required to analyze factors of green building rating system on the CO2 emission.

  • PDF

A Study on the Impact Factor of Sunlight and View by Apartment Building in its Neighboring Area (focused on the variation of building height) (공동주택에 의한 인접지역의 일조 및 조망 영향에 관한 연구 - 건물 높이 변화를 중심으로 -)

  • 김용이;최정민
    • Journal of the Korean housing association
    • /
    • v.14 no.6
    • /
    • pp.51-58
    • /
    • 2003
  • When apartment buildings are builed and re-builded, they tends to be taller. This tendency causes the problems for solar access and view in the neighboring area. So the impact factor of sunlight and view by apartment building in its neighboring area is examined. The results of this study are as follows: When analyzing sky view by dividing the sky vault into the differential area, the analysis of view can be efficient. The shorter the apartment building, the more the continuous solar access time. And the taller the building, the more the accumulated solar access time. As the height of building is taller and it is farther from the border of apartment building, view ratio, sky view ratio, and form ratio are increased. It implies that the slimmer the building, the more the visual environment can be improved.

Predicting the subjective loudness of floor impact noise in apartment building using neural network analysis (Neural Network Analysis를 이용한 공동주택 바닥충격음의 주관적 라우드니스 예측)

  • You, Byoung-Cheol;Jeon, Jin-Yong;Cho, Moon-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.351.1-351
    • /
    • 2002
  • In this research, the relationship between physical measurements and subjective evaluations of floor impact noise in apartment building was quantified by applying the neural network analysis due to its complex and nonlinear characteristics. The neural network analysis was undertaken by setting up L-value, inverse A index, Zwicker parameters and ACF/IACF factors, as input data, which came from the measurements at real suites of apartment building having various sound insulations. (omitted)

  • PDF