• Title/Summary/Keyword: Building Energy Management

Search Result 541, Processing Time 0.028 seconds

Estimating Standards and Cost Data for Modernized Korean Hosing (Hanok) (신한옥 건설 특성을 반영한 표준품셈 개발)

  • Kim, Suji;Kim, Min;Lee, Yunsub;Jung, Youngsoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.1
    • /
    • pp.66-75
    • /
    • 2016
  • As the demands for traditional Korean housing has been increased in recent years, modernized Korean traditional housing (Hanok) was developed as a way of providing Hanok for the public. Modernized Hanok attempts to remedy the shortcomings of the traditional hanok (i.e., high unit cost of building and low energy performance). In the previous researches, standardization and productivity improvement for modernized Hanok dissemination have been intensely developed. Above all, cost estimating for modernized Hanok is also an important factor. In an effort to provide effective system for Hanok construction, this paper developed 'standard cost data' for modernized Hanok. Distinct characteristic of modernized Hanok construction were analyzed first. Then, basic structure was identified, and major items were selected for Hanok standard cost data. However, this set of cost data was developed based on two mock-up Hanok projects actually constructed. Accordingly, this standard cost data will be further updated and modified by continuously accumulating real-world Hanok projects

Feasibility Appraisal and Proposal of a Pile Driving Formula for Domestic Pre-bored Pile Management (국내 매입 말뚝 관리를 위한 항타공식 활용 가능성 평가 및 제안에 관한 연구)

  • Kim, Gunwoong;Seo, Seunghwan;Kim, Juhyong;Chung, Moonkyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.11
    • /
    • pp.71-84
    • /
    • 2023
  • In accordance with Korean structural foundation design standards, dynamic or static load tests are mandated for 1 to 3% of total piles. The construction quality of the remaining 97% to 99% of piles is determined through penetration measurements. This study aims to enhance the quality control of the majority of piles by adopting a pile driving formula that considers both penetration and hammer energy. The current challenge lies in adapting existing overseas driving formulas to the domestic site conditions, characterized by shallow weathered or soft rocks, and the prevalent use of pre-bored piles. To address this, the Modified Gates formula was refined using domestic dynamic load data, thereby improving its applicability to pile management. Despite employing fewer variables, the proposed formula demonstrates a comparable accuracy to dynamic loading tests in predicting the bearing capacity of pre-bored piles. Consequently, this formula holds promise for practical use in future pile quality management.

Development of a Work Environment Monitoring System for Improving HSE and Production Information Management Within a Shipyard Based on Wireless Communication (무선 통신 기반 조선소 내 HSE 및 생산정보 관리 향상을 위한 작업환경 모니터링 시스템 개발)

  • Chunsik Shim;Jaeseon Yum;Kangho Kim;Daseul Jeong;Hwanseok Gim;Donggeon Kim;Donghyun Lee;Yerin Cho;Byeonghwa Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.5
    • /
    • pp.367-374
    • /
    • 2023
  • As the Fourth Industrial Revolution accelerating, countries worldwide are developing technologies to digitize and automate various industrial sectors. Building smart factories not only reduces costs through improved process productivity but also allows for preemptive identification and removal of risk factors through the practice of Health, Safety, and Environment (HSE) management, thereby reducing industrial accident risks. In this study, we visualized pressure, temperature, power, and wind speed data measured in real-time via a monitoring GUI, enabling field managers and workers to easily access related information. Through the work environment monitoring system developed in this study, it is possible to conduct economic analysis on per-unit basis, based on the digitization of production management elements and the tracking of required resources. By implementing HSE in shipyards, potential risk factors can be improved, and gas and electrical leaks can be identified, which are expected to reduce production costs.

The Background and Direction of R&D Project for Advanced Technology of Wastewater Treatment and Reuse (하.폐수 고도처리 기술개발사업 추진배경과 개발방향)

  • Kim, Ji-Tae;Hwang, Hae-Young;Hong, Byung-Pyo;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.277-289
    • /
    • 2011
  • Since 1980s, wastewater treatment facilities in Korea have been rapidly expanded by 90 percent as the government invested them continuously. Considering social and environmental factors such as the needs of alternative water resources for water shortages, energy saving and new energy production sources for decrease of greenhouse gases, and the demand for the improvement of the water quality in rivers and lakes, advanced technologies in wastewater treatment are essential in the 21st century. In this aspect, new conceptual technology is systematically combined with the advanced treatment technology such as the control and treatment technology of hazardous and toxic material, customized reusing skill, and energy saving/recovery technology. The new R&D project for advanced technology of wastewater treatment and reuse will focus on these advanced technologies which will improve the water quality and foster the competitiveness in world environmental markets, building a solid foundation particularly in the market of developing countries. The project will be divided up into high quality reusing of wastewater, energy self-sufficiency, and integrated management system. It will be carried out for five years, 2011~2015, as Phase I.

Characteristics and Reasonable Management Approaches of Coastal Reclamation in Korean (우리나라 연안매립의 특성 및 합리적 관리방안)

  • Eom, Ki-Hyuk;Lee, Dae-In;Kim, Young-Tae;Kim, Gui-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.3
    • /
    • pp.227-237
    • /
    • 2012
  • This paper analyzes the current status, characteristics, and problems of coastal reclamation in Korea and suggests effective management approaches. Reclamation is concentrated from the West Sea to the South Sea. In the 1980s and 1990s, most projects were intended for agricultural use, whereas in recent years reclamation for industrial and harbour sites(e.g., ship-building) have been increasing. The continuous onslaught of reclamation and development projects threatens the coastal environment, especially tidal flats and fishing areas, and fishery production has been reduced in some areas. The largest tidal flats have been used for dumping sites of dredged coastal sediments, urban development projects, and industrial complex composition. Thus, it is necessary to assess current policy using top-down approaches after establishing appropriate directions and standards for coastal management. Both short-term development profits and long-term conservation should be considered when attempting to balance development and conservation. In addition, improvements of marine environmental impact assessment and in the legal system are necessary.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

Building Energy Management System with Next Day Demand Forecasting of Building Load (익일 빌딩 부하 예측 기능을 갖는 빌딩에너지관리시스템)

  • Choi, Sang-Yule
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.119-123
    • /
    • 2014
  • The main purpose of reactive power compensation monitoring system is to manage factory electrical installation efficiently by On-Off switching reactive power compensation equipment. The existing reactive power compensation monitoring system is only able to be managed by operator whenever electrical installation needed reactive power. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a reactive power compensation monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.

Correlation Between Meteorological Factors and Hospital Power Consumption (기상요인과 병원 전력사용량의 상관관계)

  • Kim, Jang-Mook;Cho, Jung-Hwan;Kim, Byul
    • Journal of Digital Convergence
    • /
    • v.14 no.6
    • /
    • pp.457-466
    • /
    • 2016
  • To achieve eco-friendly hospitals it is necessary to empirically verify the effect of meteorological factors on the power consumption of the hospital. Using daily meteorological big data from 2009 to 2013, we studied the weather conditions impact to power consumption and analyzed the patterns of power consumption of two hospitals. R analysis revealed that temperature among the meteorological factors had the greatest impact on the hospital power consumption, and was a significant factor regardless of hospital size. The pattern of hospital power consumption differed considerably depending on the hospital size. The larger hospital had a linear pattern of power consumption and the smaller hospital had a quadratic nonlinear pattern. A typical pattern of increasing power consumption during a hot summer and a cold winter was evident for both hospitals. The results of this study suggest that a hospital's functional specificity and meteorological factors should be considered to improve energy savings and eco-friendly building.

Opportunities for Joint Cooperation in R&D for FEALAC Countries: On Nanotechnology and Biotechnology

  • Trujillo, Ivan Montenegro;Jimenez, Edgar E Gonzalez;Ospina, Monica Botero
    • STI Policy Review
    • /
    • v.7 no.2
    • /
    • pp.106-131
    • /
    • 2016
  • The general purpose of this paper is to identify opportunities for and to measure existing collaboration on research and development between institutions from the countries of Asia and Latin America in FEALAC's framework, in the fields of biotechnology and nanotechnology and their convergence. The methodological approach includes scientific and technological surveillance and research seeking to identify both the R&D and innovation capacities of the countries as well as the degree of international cooperation between countries of the two regions; case studies and a study of the governance framework of international collaboration in R&D about issues considered global challenges. The study has three main findings. First, nanotechnology, biotechnology and their convergence contribute to solving the problem of contamination by heavy metals affecting most of the countries that are part of FEALAC and to address problems arising from the accelerated rate of energy consumption, which also contributes to environmental damage. In this scenario, important business opportunities arise from the adaptation and development of bio-refinery technologies. Second, the scientific relationship between FEALAC countries, mainly between Asian and Latin American countries, is weak as can be seen in research for articles and patents. But there is plenty of room and potential for improvement. Third, current and upcoming joint R&D programs and projects should be linked both to existing governance structures and to new ones that serve as experiments of STI public policy regarding innovative management of intellectual property and capacity building. Practical implications are included in lessons learned and a set of recommendations involving a couple of proposals. One proposal calls for research and innovation in promising fields for international cooperation. Another proposal creates mechanisms in the governance framework for sharing knowledge, capacity building, and funding.

How do they Make Libraries Green?: A Case Based Study on Building Green Libraries (녹색도서관 사례분석을 기반으로 한 국내 녹색도서관 구축방향에 관한 연구)

  • Ahn, In-Ja;Kwak, Chul-Wan;Noh, Young-Hee;Park, Mi-Young
    • Journal of Information Management
    • /
    • v.43 no.1
    • /
    • pp.135-158
    • /
    • 2012
  • Since the 1990s, discussions regarding green libraries started in the U.S.A, in the name of 'library and the environment', 'Green librarians', 'constructing of environmental sources', 'noise and library', 'building libraries as an environmental alternative' and etc. Currently, green libraries certified by an evaluation system are more than 50. This study proposes a direction to build a green library. The study analyzes national and international green libraries certified by the evaluation system. The cases are analyzed based on the six evaluation factors in the LEED certification system; Sustainable Site, Water Efficiency, Energy and Atmosphere, Material and Resources, Indoor Environmental Quality, Innovation and Design Process. Since the evaluation system focuses mainly on the architectural aspects, there was a need of expanding the concept of eco-friendly in this research. The newly expanded eco-friendly concept includes services, content, and supplies of libraries.