• 제목/요약/키워드: Building Energy Assessment

검색결과 295건 처리시간 0.022초

Analysis of Economics through Control Method of Heat Source Equipment in Seasonal Air conditioning Building

  • Park, Yool;Kim, Samuel;Jung, Soon-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.209-217
    • /
    • 2003
  • The term “energy saving is economical” is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing a system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning systems. For this reason, this research can provide the economic operating number control method as basic design data. The data obtained through analysis of life cycle cost based on amount of yearly energy use, are produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating$.$cooling systems based on seasonal air conditioning system, which is widely used for medium and large size office buildings in Busan.

발전용 가스터빈의 실시간 연소안정성 평가 소프트웨어 개발 (Combustion Stability for Utility Gas Turbines : Development of a Real-Time Assessment Software)

  • 인병구;송원준;차동진
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.306-315
    • /
    • 2017
  • This study introduces a software for real-time assessment of combustion stability for utility gas turbines. The software was written with LabView, and implemented the time-domain kurtosis as a parameter to proactively access the instantaneous combustion stability during operation of the industrial gas turbine. The simple time-domain assessment algorithm incorporated in the software is advantageous over conventional frequency-domain signal processing of dynamic pressure signal since it reduces the computational cost, thereby making the algorithm more appropriate for real-time monitoring of combustion stability. Benchmark data obtained from a model gas turbine combustor were used for the reproducibility test of the software. The assessment obtained from the software agreed well with previously published results, indicating that incorporation of the software could enhance the performance of systems monitoring the combustion stability for gas turbines during power generation.

Plus50 환경공생빌딩의 열성능 평가에 관한 연구 (A Study on the Assessment of Thermal Performance of Plus50 Eco-building)

  • 이홍철;황인주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.155-160
    • /
    • 2007
  • This study describes thermal performance of Plus50 eco-building with new technology such as power window system, green wall, structure material, etc. The Plus50 eco-building is house experimental which is constructed by Korea Institute of Construction Technology. In order to estimate thermal performance of the building, TRNSYS program and Prebid, and its sub-modules are used. The results showed that maximum heating and cooling load in the building are calculated at 1st floor and 4th floor, respectively. And also energy saving of the building is calculated as over 30% compared to conventional apartment house.

  • PDF

Life cycle assessment (LCA) of roof-waterproofing systems for reinforced concrete building

  • Ji, Sukwon;Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • 제3권4호
    • /
    • pp.367-377
    • /
    • 2014
  • In this study, we investigated a life cycle assessment (LCA) of six roof-waterproofing systems [asphalt (C1), synthetic polymer-based sheet (C2), improved asphalt (C3), liquid applied membrane (C4), Metal sheet with asphalt sheet (N1), and liquid applied membrane with asphalt sheet (N2)]for reinforced concrete building using an architectural model. To acquire accurate and realistic LCA results, minimum units of material compositions for life cycle inventory and real data for compositions of waterproofing materials were used. Considering only materials and energy demands for waterproofing systems per square meter, higher greenhouse gas (GHG) emissions could be generated in the order of C1 > N2 > C4 > N1 > C2 > C3 during construction phase. However, the order was changed to C1 > C4 > C3 > N2 > N1 > C2, when the actual architecture model was applied to the roof based on each specifications. When an entire life cycle including construction, maintenance, and deconstruction were considered, the amount of GHG emission was in the order of C4 > C1 > C3 > N2 > C2 > N1. Consequently, N1 was the most environmental-friendly waterproofing system producing the lowest GHG emission. GHG emissions from maintenance phase accounted for 71.4%~78.3% among whole life cycle.

열원에 따른 열펌프의 성능 비교 및 경제성 평가 (Performance Characteristics and Economic Assessment of Heat Pump Systems with the Various Heat Source)

  • 박차식;박경우;권오경
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.23-31
    • /
    • 2011
  • The objectives of this study are to analyze the performance of a heat pump system with the various heat source and to carry out economic assessment for the heat pump system. The COP of the river water and ground source heat pump system was 20% higher than that of the air source heat pump system because river water and geothermal provide stable operating temperature compared with air temperature throughout the year. In addition, the economic assessment of a heat pump system using air, river water, and geothermal as a heat source was carried out. The ratio of the life cycle operating cost to the life cycle cost increased with the increase of building capacity. The payback period was found to be less than 3.3 and 4.5 years, respectively when the capacity of the river water and ground source heat pump was larger than 10 RT.

태양광단지의 산지입지에 따른 환경성평가 및 환경친화적 개발 방안 (Environmental Assessment and Environment-Friendly Development in Mountainous Area in Constructing Photovoltaic Complex)

  • 안세웅;주현수;이희선
    • 환경영향평가
    • /
    • 제20권2호
    • /
    • pp.141-150
    • /
    • 2011
  • The construction of photovoltaic complex in mountainous area is quickly increasing recently so that the environment assessment in constructing photovoltain complex in mountainous area was performed by comparison of $CO_{2{\cdot}}$ reduction and forest damage. The case studies for environmental value assessment, which construct photovoltaic complex in mountainous area, show that the losses of around 5.1billion won arise during 15 years. The government's official target for spreading photovoltaic energy until year 2030 can be satisfied when considering other alternative sites, improvement of technology and the alternative sites of an idle space of a building or a disused site, etc, except an undeveloped mountainous area. The construction of photovoltaic complex in mountainous area can cause the great damage to the environment, especially undeveloped mountainous area such as Baekdudaegan, and this defeat its own purpose of using photovoltaic energy. Therefore, the spread of photovoltaic complex through the additional damage of forest should be sublated.

Earthquake hazard and risk assessment of a typical Natural Gas Combined Cycle Power Plant (NGCCPP) control building

  • A. Can Zulfikar;Seyhan Okuyan Akcan;Ali Yesilyurt;Murat Eroz;Tolga Cimili
    • Geomechanics and Engineering
    • /
    • 제35권6호
    • /
    • pp.581-591
    • /
    • 2023
  • North Anatolian Fault Zone is tectonically active with recent earthquakes (Mw7.6 1999-Kocaeli and Mw7.2 1999-Düzce earthquakes) and it passes through Marmara region, which is highly industrialized, densely populated and economically important part of Turkey. Many power plants, located in Marmara region, are exposed to high seismic hazard. In this study, open source OpenQuake software has been used for the probabilistic earthquake hazard analysis of Marmara region and risk assessment for the specified energy facility. The SHARE project seismic zonation model has been used in the analysis with the regional sources, NGA GMPEs and site model logic trees. The earthquake hazard results have been compared with the former and existing earthquake resistant design regulations in Turkey, TSC 2007 and TBSCD 2018. In the scope of the study, the seismic hazard assessment for a typical natural gas combined cycle power plant located in Marmara region has been achieved. The seismic risk assessment has been accomplished for a typical control building located in the power plant using obtained seismic hazard results. The structural and non-structural fragility functions and a consequence model have been used in the seismic risk assessment. Based on the seismic hazard level with a 2% probability of exceedance in 50 years, considered for especially these type of critical structures, the ratios of structural and non-structural loss to the total building cost were obtained as 8.8% and 45.7%, respectively. The results of the study enable the practical seismic risk assessment of the critical facility located on different regions.

북극권 자원 개발사업의 환경영향평가(EIA)를 위한 정보 구축 방안 (Study of Information System for the Environmental Impact Assessment (EIA) of the Arctic Development Project)

  • 김세원;김영석
    • 한국지반신소재학회논문집
    • /
    • 제18권4호
    • /
    • pp.53-61
    • /
    • 2019
  • 북극권에는 미개발된 막대한 에너지·자원이 매장되어 있다. 지구온난화로 인해 북극 항로의 이용이 가능해지고, 자원개발에 대한 관심이 높아짐에 따라 극지 인접국들과 선진국들은 국가적 차원에서 북극권 개발과 건설 사업을 활발히 추진하고 있다. 동시에 북극권 자원 개발과 자원 이송에 따른 환경오염 문제도 꾸준히 제기되어 왔다. 오늘날 환경 문제는 북극권 개발사업의 비용뿐 아니라, 사업 자체의 성공 여부에 중대한 영향을 미치고 있다. 따라서 북극권 자원 개발사업을 위해서는 에너지·자원 개발 및 이송과 관련된 기술 확보와 함께 환경영향평가(Environmental Impact Assessment, EIA)에 대한 전략 수립이 반드시 필요하다. 본 논문에서는 북극권 자원 개발 시, 고려해야 할 환경영향평가의 특성과 절차를 살펴보고, 그에 필요한 정보를 체계적으로 관리하기 위한 시스템 구축 방안을 고찰하였다. 본 시스템은 북극권 환경영향평가에 필요한 정보 데이터베이스와 그를 활용하는 응용시스템으로 구성되며, 북극권 자원 개발사업을 위한 전략수립 등을 위하여 활용될 것으로 기대된다.

비선형 유한요소 해석을 이용한 PWR 격납건물의 내압 취약도 평가 (Assessment of the Internal Pressure Fragility of the PWR Containment Building Using a Nonlinear Finite Element Analysis)

  • 함대기;박형규;최인길
    • 한국전산구조공학회논문집
    • /
    • 제27권2호
    • /
    • pp.103-111
    • /
    • 2014
  • 본 연구에서는 비선형 유한요소 해석 기법을 적용한 격납건물의 내압취약도 평가를 수행하였다. 대상 구조물은 국내 대표적인 가압경수로형 원전 격납건물 중 하나로 하였다. 비선형 극한내압 해석을 위해 대규모 개구부를 고려한 격납건물의 3차원 유한요소 모델을 도출하였다. 재료 특성 및 구조적 성능에 내포된 불확실성을 고려하기 위하여 각 변수들의 변동성에 대한 극한내압 성능의 민감도 해석을 수행하였다. 민감도 해석 결과를 통해 확률론적 내압 취약도 평가를 위한 불확실성 변수 및 분포 특성을 도출하였다. 현재의 텐던 긴장력 상태를 고려하기 위하여 가동 중 검사 보고서에 기록된 텐던 긴장력 값을 중앙값으로 적용하였다. 누설(leak)과 파단(rupture)을 파괴모드로 정의하고, 각각에 대한 극한내압 취약도 평가를 위하여 한계상태를 정의하였다. 각 파괴모드에 대한 대상 격납건물의 내압취약도를 내압 성능 중앙값, 고신뢰도 저파괴확률 성능값, 신뢰도 수준에 따른 취약도 곡선을 통하여 제시하였다. 누설 및 파단 파괴모드에 대한 고신뢰도 저파괴확률값은 각각 0.7991 MPa, 0.8691 MPa로 평가되었다.

Pit를 이용한 건물 급기방식의 효용성 평가에 관한 사례 연구 (A Case Study on Effectiveness Assessment of Supply Air System Using Pit in Building)

  • 민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.16-21
    • /
    • 2017
  • In this study, the flow effect of warming and cooling in the air supply of a pit for air conditioning were evaluated in BS art museum. We simulated the flow temperature for a pit winter and summer seasons using computational fluid dynamics. Consequential, energy saving, energy saving costs and initial payback periods were calculated and the following conclusions were drawn. The warming effect of the winter increased by $18.1^{\circ}C$ and $0.2^{\circ}C/m$ and the cooling effect of the summer decreased by $6.1^{\circ}C$ and dropped to $0.07^{\circ}C/m$. Energy saving appeared to be 19.1 kW in the summer and 54.3 kW in winter. Energy saving costs ranged from 2,567,119 won/year to 5,134,238 won/year and at minimum, initial payback period for initial investment was 3.9 years. As a result, the air supply system using an existing pit without any burden on initial investment costs is believed to contribute to energy saving through warming and cooling of unutilized energy effects.