건축자재 운송거리에 따른 탄소배출량 분석에 관한 연구 (A Study on the Analysis of Carbon Emissions by Transportation Distance of Building Materials)

  • 김현숙;태성호;임효진;장형제;이충원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.125-126
    • /
    • 2022
  • As environmental problems around the world become serious, Korea has also raised the greenhouse gas reduction in the building sector to 32.8% compared to 2018, and efforts to reduce carbon in buildings are expanding. Recently, research is being actively conducted to reduce carbon in the long term by expanding the scope of greenhouse gas indirect emissions (Scope3), and even within the domestic Green Standard for Energy and Environmental Design(G-SEED) by quantitatively evaluating the environmental impact of buildings during the entire life cycle. However, it is difficult to accurately evaluate the carbon emission of the transportation process by assuming the material transport distance in the evaluation of the Life Cycle Assessment(LCA). Therefore, in this study, the main building materials of the building were selected through case evaluation and the carbon emission of the material transport process was derived based on the actual transport distance, and this was compared and analyzed with the theoretical LCA results.

  • PDF

옥상녹화 적용확대를 위한 녹색건축인증제도 개선방안 연구 - 미국 LEED 및 영국 BREEAM의 비교·분석을 중심으로 - (Study on Improvement Measures of Green Standard for Energy and Environmental Design for Expansion of Applying Green Roof - Focused on LEED in the USA and BREEAM in the UK -)

  • 김지현;권혁삼;김정곤;이범식
    • 대한건축학회논문집:구조계
    • /
    • 제34권2호
    • /
    • pp.75-82
    • /
    • 2018
  • Green roof in Korea has been recognized as part of landscape area and local governments enacted municipal ordinance for supporting green roof thereby assisting part of expenses spent for green roof within a range of budget for buildings which are eligible for the green roof support of existing buildings. However, it is necessary to enforce a regulation of mandatory green roof for new buildings in order to expand green roof application and provide a variety of assistances such as subsidy payment, tax relief, and mitigation of floor area ratio-related regulation as done in other advanced nations. In particular, LEED(Leadership in Environmental and Energy Design) in the USA applies additional point directly for green roof in terms of the reduction in heat island effects. For example, the following items are beneficial to have additional points: habitat preservation or restoration, external space, rainwater management, reduction in outdoor water usage, minimum energy performance, and optimum energy performance. In addition, the BREEAM(Building Research Establishment Environmental Assessment Method) in the UK specifies green roof as one of assessment items to be complied in terms of diversity of species. As such, LEED and BREEAM reflect direct and indirect effects of green roof on assessment criteria, which suggest a direction to green building certification criteria in Korea where only additional points are given for green roof according to soil depth.

Opendata 기반 포항 및 경주지진에 의한 건물손상 평가 (Earthquake Damage Assessment of Buildings Using Opendata in the Pohang and the Gyeongju Earthquakes)

  • 임승현;양범주;전해민
    • 한국지진공학회논문집
    • /
    • 제22권3호
    • /
    • pp.121-128
    • /
    • 2018
  • Severe earthquakes can cause damage to society both socially and economically. An appropriate initial response can alleviate damage from severe earthquakes. In order to formulate an appropriate initial response, it is necessary to identify damage situations in societies; however, it is difficult to grasp this information immediately after an earthquake event. In this study, an earthquake damage assessment methodology for buildings is proposed for estimating damage situations immediately after severe earthquakes. A response spectrum database is constructed to provide response spectra at arbitrary locations from earthquake measurements immediately after the event. The fragility curves are used to estimate the damage of the buildings. Earthquake damage assessment is performed from the response spectrum database at the building scale to provide enhanced damage condition information. Earthquake damage assessment for Gyeongju city and Pohang city were conducted using the proposed methodology, when an earthquake occurred on September 12, 2016, and November 15, 2017. Results confirm that the proposed earthquake damage assessment effectively represented the earthquake damage situation in the city to decide on an appropriate initial response by providing detailed information at the building scale.

공동주택의 라이프사이클을 통한 지속가능성과 친환경성 평가기법에 관한 연구 (Evaluation of Sustainable and Environmentally Friendly Building through the Life-cycle of Apartment Buildings)

  • 김삼열;김세환;이성
    • KIEAE Journal
    • /
    • 제1권1호
    • /
    • pp.11-16
    • /
    • 2001
  • Concern about global environment has been increasing in recent years. Efforts to minimize the environmental impact to the globe as well as human beings have increased, especially in the late twentieth century. The study researches one of the solutions for the environmentally friendly building construction, which can contribute to sustaining the world environment. Assessment and proposals are made for high-rise apartments, one of the most popular construction types nowadays in Korea. Careful building design and construction for apartment buildings could reduce the environmental impact significantly without lowering standards of living. Since the volume of high-rise apartment construction is so great, a small improvement in each building will make a great contribution. Assessments are made over the life-span of apartment buildings. A tool has been made through references from western examples. mainly from BHEEAMs made in the United Kingdom. The components of the tool include passive design strategies, building materials. energy consumption during building operation, and management and maintenance. Co-relationship between buildings and ten environment in Korea is searched. Korean high-rise apartments are assessed with the tool and suggestions for sustainable development are made mainly for improvement of embodied energy of building materials and the life of buildings.

  • PDF

도시 형태에 따른 신재생에너지 잠재성 평가에 관한 연구 (Assessment of Potentiality of Renewable Energy Based Urban Forms)

  • 정아름;정민희;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.22-32
    • /
    • 2010
  • The world is facing environmental problem described as climate change and exhaustion of fossil fuel. In order to solve theses problems, importance of renewable energy is extremely growing. For stable energy supply, it is need to apply hybrid renewable energy systems in urban-scale, because some renewable energy system' outputs are greatly influenced by climatic condition. Especially, solar irradiation and wind velocity are influenced by urban geometric environment as well as climatic condition. Therefore it is necessary to evaluate the renewable energy potential according as urban form. This study aims to evaluate the potential of solar energy and wind energy in urban-scale and classify urban type according as characteristics of urban forms. The results of this study will be used to develop renewable energy system application guidelines for urban and energy planning.

해외 사례분석을 통한 Cool Roof의 도입 방안 (Introducing Strategy of Cool Roofs based on Comparative Evaluation of Foreign Cases)

  • 최진호;엄정섭
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.591-605
    • /
    • 2010
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. This paper reviews worldwide experiences (USA, Japan and EU etc) for the potential benefits cool roofs offer in relation to building energy saving for comparison purposes. It is confirmed that there is a significant potential to the energy saving by introducing the cool roof in a Korean climate because of similarity in terms of HDD (Heating Degree Day) and CDD (Cooling Degree Day) as those countries reviewed. Such a comparative study highlights that the type of measurements performed and the quantitative parameters reported from the countries should be standardized in Korean context in order to implement further comparable experiments for scientifically sound investigations. It is anticipated that this research output could be used as a valuable reference in implementing a Nation-wide cool roofing strategy in the central and local governments since a suitable technical, more objective direction has been proposed based on the measured, fully quantitative performance of the involved components of a cool roof system in the global context. From this critical review, a very important step has been made concerning the practicality of cool roof in Korean context. Ultimately, the suggestion in this paper will greatly contribute to opening new possibilities for introducing cool roof in this country, proposed as an initial aim of this paper.

Barrette 파일을 이용한 지열시스템의 채열 성능 예측 및 경제성 분석에 관한 연구 (An Economic Analysis and Performance Prediction for a Ground Heat Pump System with Barrette Pile)

  • 채호병;남유진;박용부
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.600-605
    • /
    • 2013
  • Ground source heat pump systems (GSHP) can achieve higher performance of the system, by supplying more efficient heat source to the heat pump, than the conventional air-source heat pump system. But building clients and designers have hesitated to use GSHP systems, due to expensive initial cost, and uncertain economic feasibility. In order to reduce the initial cost, many researches have focused on the energy-pile system, using the structure of the building as a heat exchanger. Even though several experimental studies for the energy-pile system have been conducted, there was not enough data of quantitative evaluation with economic analysis and comprehensive analysis for the energy-pile. In this study, a prediction method has been developed for the energy pile system with barrette pile, using the ground heat transfer model and ground heat exchanger model. Moreover, a feasibility study for the energy pile system with barrette pile was conducted, by performance analysis and LCC assessment. As a result, it was found that the heat exchange rate of a barrette pile was 2.55 kW, and the payback period using LCC analysis was 8.8 years.

현장 실험을 통한 Sputter Coating 컬러 BIPV 모듈의 발전성능 평가 (Performance Assessment of Sputter-Coating-Colored BIPV Modules Through Field Test)

  • 이효문;윤종호;김현일;이건환
    • 한국태양에너지학회 논문집
    • /
    • 제40권5호
    • /
    • pp.1-12
    • /
    • 2020
  • To assess the performance and characteristics of colored building-integrated photovoltaic (BIPV) modules, a comparative assessment of empirical performance was conducted on colored BIPV modules (gray, blue, and orange) and general BIPV module. These modules were installed on the south-facing slope (30°) for comparative assessment through a field test. Monitoring data were collected every 10 min from December 20, 2019 to January 21, 2020 and used to performance and characteristics analysis. Performance ratio and module efficiency were utilized during performance indexing for comparative assessment. For general BIPV modules, the operational efficiency was analyzed at 16.63%, whereas for colored BIPV modules, 13.70% (gray), 15.12 % (blue), and 14.49% (orange) were analyzed. It was discovered that the efficiency reduction caused by transmission losses owing to the application of colored cover glasses were 17.74% (gray), 9.05% (blue), and 9.86 % (orange), under field testing conditions. These values turned on an additional 7% reduction in efficiency for gray BIPV modules, compared to the degradation resulting from transmission drop (gray: 10.87%, blue: 8.99%, and orange: 9.02%) calculated using the efficiency of each module in standard test conditions (STC). Performance ratio analysis resulted in the following values: 0.92 for general BIPV modules, and 0.85 (gray), 0.91 (blue), and 0.91 (orange) for colored BIPV modules. As demonstrated by the above results, modules with a colored cover glass may differ in their operational performance depending on their color, unlike general modules. Therefore, in addition to the performance evaluation under STC, additional factors of degradation require consideration through field test.

연료전지 지열히트펌프 마이크로제너레이션 IEA ECBCS Annex 54 경제성 평가 연구 (IEA ECBCS Annex 54 Economic Assessment Study of a Fuel Cell Integrated Ground Source Heat Pump Microgeneration System)

  • 나선익;강은철;이의준
    • 설비공학논문집
    • /
    • 제26권5호
    • /
    • pp.199-205
    • /
    • 2014
  • The integration of FC (Fuel Cell) and GSHP (Ground Source Heat Pump) hybrid system could produce a synergistic advantage in thermal and electric way. This study intends to analyse the economical aspect of a FC integrated GSHP hybrid system compared to the conventional system which is consisted with a boiler and a chiller. Based on the hourly simulation, the study indicated that GSHP system and FC+GSHP hybrid system could reduce the energy consumption on a building. The method of the economic assessment has been based on IEA ECBCS Annex 54 Subtask C SPB(Simple Payback) method. The SPB was calculated using the economic balanced year of the alternative system over the conventional (reference) system. The SPB of the alternative systems (GSHP and FC+GSHP) with 50% initial incentive was 4.06 and 26.73 year respectively while the SPB without initial incentive of systems was 10.71 and 57.76 year.

건축물 생애과정에서의 이산화탄소 배출량 계산 프로세스에 관한 연구 (A Study on the Calculation Process of Carbon Dioxide Emission for Buildings with Life Cycle Assessment)

  • 정영선;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.23-30
    • /
    • 2011
  • International cooperation to reduce greenhouse gas emissions is expected to provide a big crisis and a great opportunity at the same time for our industry that heavily consumes energy. To cope actively with the international environmental regulation, such as the Framework Convention on Climate Change, quantitative measurement of the volume of greenhouse gases emitted by various industries and quantitative prediction of the greenhouse gas emissions of the future are becoming more important than anything else at the national level. This study aims to propose the calculation process of carbon dioxide($CO_2$) emission for building in life cycle. This paper describes and compares 9 different tool for environmental load estimation with LCA. This study proposed the calculation process for quantitatively predicting and assessing $CO_2$ emissions during the life cycle of buildings based on the life cycle assessment(LCA). The life cycle steps of buildings were divided into the design/supervision, new construction, repair, renovation, use of operating energy in buildings, maintenance, and reconstruction stage in the life cycle inventory analysis and the method of assessing the environmental load in each stage was proposed.