• Title/Summary/Keyword: Building Design Evaluation

Search Result 990, Processing Time 0.027 seconds

A Study on Design Tendencies in Office Buildings of Public Institutions after Reinforcement of the Building Energy Performance Criteria in Korea (건물에너지성능기준 강화 이후 국내공공기관 업무용 건축물의 디자인경향)

  • Lee, Ah-Young
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.139-149
    • /
    • 2011
  • This study focuses on design tendencies in office buildings of public institutions after tightening up Korea's building energy performance criteria. Important office design criteria and recommendations pay attention to the issues such as building orientation, greening buildings, building form, space and envelop by intensifying building energy performance related laws, government guidelines and evaluation systems. The design tendencies explored in this research are as follows. Office buildings mainly face south and have various types of indoor and roof green spaces not for ecological reasons but for the rest. Building depth becomes thinner and atria are inserted into office buildings to improve daylighting and natural ventilation. Building cores are located on north or west and east sides acting as buffer spaces to reduce heat loss and to block solar radiation. Office building envelop design includes various creative ideas to control or utilize solar energy as like three dimensional or double structured skin and window size variation to cope with the intensity of solar radiation. Further, solar energy generation systems are integrated with building component such as roofs, sun screens and windows. This study demonstrates that government's reinforcement of the building energy performance criteria drives the change in design methods and approach.

A Study of Thermal Performance Evaluation Index for Building (건물의 열성능 평가 지표에 관한 연구)

  • Kim, Mi-Hyun;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.67-75
    • /
    • 2007
  • This study intends to the adequacy inspection of the room temperature variation rate that is available in the building heat performance evaluation index, so we performed the sensitivity analysis about the room temperature variation rate and the energy consumption in the room. For these purpose, we supposed the models which are composed of the various window area, insulation thickness and ventilation rate. Then we analyzed the simulation using the ESP-r and Seoul weather data. In this research, the pattern of the increasing & decreasing rate of annual load according to the change of the various design factors is similar to the pattern of increasing & decreasing rate of not the K-values but the room temperature variation rate. Also we derive the optimum value of the various design factors and the room temperature variation rate in this analysis model. Further study is to be required the development of convenient tool to use in the real design.

A Study on Advanced Analysis of Construction Project Performance Evaluation (건설사업 수행성과평가에 대한 분석 고도화 연구)

  • Kim, Kyong hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.329-330
    • /
    • 2023
  • The performance of the construction project is to be evaluated within 60 days of completion, according to relevant laws. It evaluates cost, construction period, design change, re-construction, safety, etc. for each project stage. And the project owners are inputting the evaluation results of the construction work into the construction project information system(CALS). The post-evaluation result information entered in this way can be referred to in the basic design of the construction project by referring to the related contents if there is a similar construction in the future. And It can also be used to predict and respond to the required period and cost by analyzing the accumulated data. In this study, in order to provide reference data that can be used in similar projects in the future, the latest analysis methods are reviewed and the possibility of future application is considered. Accordingly, this study intends to focus on the construction cost part among the indicators such as construction cost, construction period, design change, and re-construction that are currently being dealt with in post evaluation.

  • PDF

Seismic Performance Evaluation of An Old School Building Through Linear Analysis (선형구조해석을 통한 노후된 학교시설 내진성능평가)

  • LEE, Do Hyung;Kim, Taewan;Kim, Seung Re;Chu, Yurim;Kim, Hyun Sik
    • Journal of Industrial Technology
    • /
    • v.38 no.1
    • /
    • pp.21-27
    • /
    • 2018
  • In January 2018, the Ministry of Education published "Seismic design criteria for school buildings" and "Manual for seismic performance evaluation and retrofit of school buildings" to evaluate seismic performances through linear analysis. This paper evaluates the seismic performance of an old school building through the linear analysis. The target building was constructed in the late 1970s, and the seismic-force-resisting system was assumed to be a reinforced concrete moment frame with an un-reinforced masonry wall. As a result of the evaluation, the target building does not satisfy the 'life safety' level of 1.2 times the design spectrum. The average strength ratio of moment frames, an indicator of the level of seismic performance tends to be controlled by beams. However, through the Pohang earthquake, it was known that the short column effect caused by the partially infilled masonry wall caused shear failure of the columns in school buildings. Therefore, it is necessary to improve the linear analysis so that the column controls the average strength ratio of moment frames.

MECHANICAL DESIGN APPROACH FOR THE VIRTUAL MOCK-UP STUDY OF BUILDING ENVELOPE DESIGN AND FABRICATION

  • Minjung M.;Yongcheol L.
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.158-162
    • /
    • 2013
  • Building envelope systems with growing complexity in geometry and performance criteria demand adapted workflow processes toward the efficient integration of their design and fabrication. To facilitate integration of the workflow process, this study analyzes relationships among teams who share digital models and exchange information that help project participants identify areas of improvement in task allocation and exchanges among various actors, systems, and activities. In addition, major gaps identified in knowledge transfer, project tracking, and design integration during the performance evaluation stages, emphasize the need for a more comprehensive approach to integrating the design, the fabrication, and the construction parameters of building envelope systems. To evaluate the effectiveness of streamlining interactions of design parameters with fabrication constraints and constructability assessments, this paper examines a mechanical design approach as it applies to various project scenarios to develop a mechanical solution for streamlining building envelope design and construction workflow.

  • PDF

A Methodology for Using ChatGPT to Improve BIM-based Design Data Evaluation System (BIM기반 설계데이터 평가 시스템 개선을 위한 ChatGPT활용 방법론)

  • Yu, Eun-Sang;Kim, Gu-Taek;Ahn, Yong-Han;Choi, Jung-Sik
    • Journal of KIBIM
    • /
    • v.14 no.2
    • /
    • pp.25-34
    • /
    • 2024
  • This study proposes a new methodology to increase the flexibility and efficiency of the design data evaluation system by combining Building Information Modeling (BIM) technology in the architectural industry, OpenAI's interactive artificial intelligence, and ChatGPT. BIM technology plays an important role in digitally modeling and managing architectural information. Since architectural information is included, research and development are underway to review and evaluate BIM data according to conditions through program development. However, in the process of reviewing BIM design data, if the review criteria or evaluation criteria according to design change occur frequently, it is necessary to update the program anew. In order for designers or reviewers to apply the changed criteria, requesting a program developer will delay time. This problem was studied by using ChatGPT to modify and update the design data evaluation program code in real time. In this study, it is aimed to improve the changing standards and accuracy by enabling programming non-professionals to change the design regulations and calculation standards of the BIM evaluation program system using ChatGPT. In this study, in the BIM-based design certification automation evaluation program, a program in which the automation evaluation method is being studied based on the design certification evaluation manual was first used. In the design certification automation evaluation program, the programming non-majors checked the automation evaluation code by linking ChatGPT, and the changed calculation criteria were created and modified interactively. As a result of the evaluation, the change in the calculation standard was explained to ChatGPT and the applied result was confirmed.

Prediction and Evaluation of the Wind Environment in Site Planning of Apartment Housing by CFD (아파트 주거의 배치계획에 있어 CFD에 의한 풍환경의 예측과 평가)

  • Sohn, Saehyung
    • KIEAE Journal
    • /
    • v.10 no.2
    • /
    • pp.63-69
    • /
    • 2010
  • Diverse problems in wind environment has occurred through rapid urbanization and growth of high-rise building numbers, This study aims to propose the CFD (Computational Fluid Dynamics) simulation method and evaluation standard of wind environment in site planning of high rise apartment housing. The CFD simulation method proposed in this study is not existing detail simulation, but it is the method that a designer can correct and develop the design through immediate evaluation of design options in concept design phase. Therefore, the proposed CFD simulation method of wind environment in this study uses the BIM based CFD tool in which the 3D model in concept design phase can be used as for the CFD simulation. In this paper, the study examines existing evaluation standards of comfortableness level in wind environment for pedestrian near buildings, and selects new evaluation method which is possible to apply to the proposed CFD simulation method. In addition, it is to examine calculation time-spending and appropriate mesh division method for finding CFD result which is useful to find the best design options in aspect of wind environment in concept design phase. Furthermore, it proposes the wind environment evaluation method through BIM based CFD simulation.

A PROPOSAL OF CONSTRUCTABILITY REVIEW IN THE BASIC DESIGN STEP FOR DESIGN-BUILD PROJECTS

  • Sung-Wook Choi;Young-Woong Song;Yoon-Ki Choi;Dong-Woo Shin;Jae-Youl Chun
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.1150-1153
    • /
    • 2005
  • The orders of Design-Build Delivery System (DBDS) in a large and public construction project have been increasing. Single Source Responsibility (SSR) for design and construction, which contributes to quality improvement of design and construction, has been performed. The DBDS performs SSR for design and construction, but, it has not maximized effect because of the dissatisfied alternative analysis procedures which are based on constructability evaluation and the information system in the design step. In this research, Constructability Evaluation Factors (CEFs) that must be evaluated, investigated, and reflected in the basic design step for design-build projects. The CEF proposed and the business process of each conductor has been systematized. To propose constructability evaluation factors, first classify drawing information by the constructability evaluation sphere. CEFs must be proposed to evaluate factors according to interference among work items. Second, applicable CEFs must be classified by preference ranking and weight. Third, the values of constructability factors in accordance with building elements and work items, need to be calculated. Finally, the CEFs proposal will support rational decision making, design cost reduction, and quality improvement through the values for constructability of building elements and work items.

  • PDF

Literature Review of Construction Guide and Design Standard for Root Barrier Design of Green Roof System (인공지반녹화용 방근 설계 및 품질 향상을 위한 가이드라인 및 기준 고찰)

  • Suh, Jung-Il;Kim, Young-Sam;Shin, Hong-chol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.239-240
    • /
    • 2019
  • The existing evaluation of root barrier resistance takes at least two years as an evaluation based on plant growth, and it is difficult to determine early performance in the process of quality control in the field. In this study, thus, the direction of the root barrier resistance evaluation system was presented by considering the construction specifications and design standards for root barrier design. As a result, it was necessary to establish a test method for reproducing simple and consistent test results for evaluating the durability of root barrier materials.

  • PDF

A Study on the Sri Autobindo Center Guest House Design (Sri Autobindo Center Guest House 디자인에 관한 연구)

  • 손철수
    • Journal of the Korean housing association
    • /
    • v.12 no.4
    • /
    • pp.227-230
    • /
    • 2001
  • The Sri Autobindo Learning Center(SALC) is sponsoring the development of a passive solar village in Creston, Colorado, Situated near the Sangre de Cristo mountains, Savitri Village will be one of several religious communities in the area. This village will incorporate 12 permanent residences and teaching and guest facilities for fifty to one hundred people. The purpose of this study is to evaluate the passive solar elements and performance of guest house at the Sri Autobindo Learning Center(SALC). To do this evaluation, the following tasks needed to be addressed. 1. the guest house design 2. the location of weather data 3. The determination of the building heating load As part of the evaluation process, guest house design will be modified and the building load and solar saving recalculated. This process will be completed until the building performance is deemed satisfactory. The conclusion is as follows; The high solar savings fraction predicted by SUNCODE should taken as an indication that further design changes would probably not be cost effective. But adding removal overhangs or other low costs measures to increase comfort in the summer appear to be appropriate.

  • PDF