• Title/Summary/Keyword: Building Corridor

Search Result 134, Processing Time 0.019 seconds

A Study on the Location and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 배치 및 규모에 관한 연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.93-104
    • /
    • 2019
  • Purpose: To establish the building guidelines and to analyze the function of Regional Public Hospitals, the survey was conducted primarily on the current status focusing on the location and relationship of the department, area composition ratio, area per bed, and area per operating room. Methods: The research methods of this paper are as follows. 1) A literature survey on the function of the operating and related departments, 2) A drawing analysis for spatial composition and net area calculation. Results: The area of the Operation Department in the Regional Public Hospitals with 200 to 300 beds are as follows. Area ratio: 3.35%, area per Bed: 2.53㎡/bed, the number of beds per operating room: 64.37bed, area per operating room: 146.46㎡/n, area per operating room by plan type: integration corridor 133.84㎡/n, separation corridor 184.82㎡/n. Implications: This paper analyzed data on the current state of Operation Departments for setting up the function and role for the Regional Public Hospital. In the future, it is also required to provide size that takes into account user behavior and the user's psychological aspect in order to suggest appropriate area.

Urban Climate Mapping - The Case of Sanggye 4-Dong - (도시기후지도의 작성 -상계 4동을 중심으로-)

  • 송영배
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.6
    • /
    • pp.27-36
    • /
    • 2002
  • The objective of this study is to improve the quality of the atmospheric environment by incorporating the factors of meteorology and urban climate into the field of urban and environmental planning. To this end, we have conducted a study on CLIMATOP and the mapping of urban climate, which are basic data used to analyze changes in climatic factors and the stagnation and accumulation of air pollutants. In particular, we focused on understanding the formation and movement of cold fresh air and its influx into urban areas by measuring and analyzing climatic factors. As a study result, classification criteria far CLIMATOP and a urban climatic map were made. In addition, we analyzed a digital elevation model, climatic data, and isothermal curves. As a result, we identified the corridor through which cold fresh air moves. We also observed that the temperature of the fluxed cold fresh air increased as land use changed. When the results of this study are applied to urban re-development and re-building projects, which require preliminary environmental assessment and environmental impact assessment, the practice proposed by this study is expected to contribute to the natural purification of air pollution activating the movement of cold fresh air and its influx into urban areas.

A Study on the Design Characteristics and the Origin of Three-story Section in the Unite d'Habitation at Marseilles (마르세이유 거대 주거동의 건축설계 특성(特性)과 단면 3층 단위체 기원(起源)에 관한 연구(硏究))

  • Yoon, Chae-Shin
    • Journal of architectural history
    • /
    • v.7 no.4 s.17
    • /
    • pp.61-75
    • /
    • 1998
  • The Unite d'Habitation at Marseilles was an experimental project that Le Corbusier had been waiting for since 1920s in order to explore his ideals and visions in mass housing and city planning. As a leader of the first generation members in CIAM, Le Corbusier tried to give a new form and an order to the Unite d'Habitation at Marseilles in both building design and city planning level. The purpose of this research is to investigate the design characteristics of the Unite d'Habitation at Marseilles in three different levels of built environment with a particular emphasis on the process through which an original form is derived from its contextual settings. In the level of city planning, Le Corbusier aimed to reshape traditional low-rise urban housing by deploying several Unites spaciously. Le Corbusier believed that the spacious deployment of Unites would bring us both the functional economy in the city and the natural amenity in the suburbs. As Unite d'Habitation would be called frequently as vertical garden city, the influence of suburban garden city on Unite d'Habitation is apparent. In the building level, the binomial harmony of individual-collectivity was pursued by providing three different public floors and by combining 23 different family unit types in the Unite d'Habitation at Marseilles. In order to visualize the concept of object-type, family units were prefabricated and inserted into the structural frame of the Unite d'Habitation at Marseilles. Two family units are combined to make a three-story section with street corridor in the middle. This three-story section unit is very original as it has access corridor every third floor and each unit could have considerable depth with the help of the living space of two story height. In consideration of formal and plan similarity as well as contextual edivdence, it is concluded that the three-story section of the Unite d'Habitation is derived more from Narkomfin Apartments than from the monastery at Ema or Immuble Villas.

  • PDF

A Study on the Propagation Characteristics of Fire Alarm Sound in Buildings (화재비상경보음의 건물 내 전달특성에 관한 연구)

  • Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.153-160
    • /
    • 2009
  • This study aims to review the propagation characteristics of fire alarm sound in building through computer simulation. In order to achieve this goal, the sound power level of existing three different emergency alarms were measured in an anechoic chamber. Sound power level of alarm bell was 98.6dB and electronic-siren speaker was 95.7dB, and electronic-siren phon was 101.8dB at the voltage of DC 24V in the condition of anechoic chamber. As the results of acoustic simulation, it was shown that sound levels at the corridor of the building were relatively high and even. But, there were large difference in sound level at all the frequency bands between corridor and lecture rooms. This mean that alarm sound couldn't be recognized sometimes in lecture rooms. Through the computer simulation, the propagation characteristics of fire alarm sound could be forecasted and compared due to plans of buildings.

User Evaluation of Common Spaces in Office Building - Focused on Universal Design - (오피스 건물의 공용공간 디자인에 대한 사용자 평가 - 유니버설 디자인을 중심으로 -)

  • Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.1
    • /
    • pp.20-29
    • /
    • 2012
  • The study was intended to evaluate common spaces of office building in view point of universal design. The common spaces were access road, main entrance, parking lot, corridor, and restroom. Two office buildings in Centum city of Busan were evaluated by their workers, each 100 ones. The check list for evaluating them consisted of 36 universal design elements which related to five common spaces. First, there were many universal design elements which need to be improved. Second, among five common spaces, restroom has the most elements to be rated low. First of all, at least one restroom for wheelchair should be provided each floor. Third, even though both of two office buildings were recently built, there were significant difference between their users' evaluations. This implies that the concept of universal design is not applied to office buildings well. Fourth, there were significant difference among users' evaluations according to age, especially in case of design related elements. This means that users' age is an important factor to be considered.

  • PDF

A study on the construction of High-ways and Ecological corridors (고속도로 건설과 생태통로에 관한 연구)

  • Lee, Kwan-Young;Jung, Jong-Dae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.1
    • /
    • pp.73-78
    • /
    • 2006
  • Constructing a long, linear structure such as a high-way may cause the break-up of the natural ecology by cutting off the trails of animals. We could observe 12 kinds of mammals, 49 kinds of birds and 10 kinds of amphibia and reptilia at the research area. With this research, we were so sure of the necessity of building ecological corridors to prevent the ecological break-up of wild animals that we studied the building and maintaining of 3 types of ecological corridors; tunnel types, over-bridge type and line type.

  • PDF

Path of Water Leakage of PC Apartment House 15 Years Have Elapsed (15년 경과한 PC아파트의 누수경로 조사결과)

  • Lee, Jung-Hun;Bae, Kee-Sun;Kim, Sang-Youn;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.156-157
    • /
    • 2014
  • PC apartment house 15 years have elapsed have various deteriorations by water leakage in roof and wall. The prior investigation such as investigating of leakage repair history of PC apartment and the field investigation were carried out to solve the water leak problem in its structure. The path of water was analyzed on the parts of greatest water leak such as roof parapet, roof floor, side wall, corridor and balcony. As a result, the specific path of the water leakage was identified in various structure units.

  • PDF

A study Fire Protection and Evacuation System for Buildings (건축물의 방화 및 피난계획에 관한 연구)

  • 이경수;임만택
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.9-16
    • /
    • 1988
  • This study is intended to suggest some ideal measures available in the course of construction from the viewpoint of an architect to reduce damage of human lives and Properties caused by fire accidents in buildings. For this study, 7 buildings burnt by conflaguration in Seoul during the years of 1985 and 1987 are picked up, and 105 withnesses, who were present in one of them at them at fire, are traced for personal interview and respones to the written questionaire about 5 main issues; their perceptional behaviour, their emotional state at that time, their reactions to avoid danger, their escape routes, and their usual awareness to prevent fire. Some desirable measures suggested here are ;making Provisions to install fire centers in large buildings and underground structures in the fire fighting law, and requlating to compose fire units appropriate to the quantity of combustibles inside, limit the length of a blind corridor, furnish balustrade, and limit the width of the landing of the stairs in building code and regulations. Such measures should be considered from the time of planning to construct a building, and some drill and education in fire prevention is demanded for the occupants of the buildings too.

  • PDF

Analysis of Technical Requirement for Implementation of Multi-trade Prefabrication (Multi-trade Prefabrication 기법 적용을 위한 기술적 요구사항 분석)

  • Jang, Se-Jun;Lee, Ghang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.113-114
    • /
    • 2016
  • This paper proposes a technical requirements analysis of implementation of multi-trade prefabrication. Recently, there has been a rise in the use of prefabrication to minimize on-site work for time reduction to increase productivity. Prefabrication technique is evolved into multi-trade prefabrication combining other trades from single-trade prefabrication. For implementation of new technique, not only itself but complementary techniques have to be prepared. In this paper, MEP corridor rack, a major item of multi-trade prefabrication, was implemented in the test bed and its process was analyzed to find out technical requirements. As a result, comparatively high level of IT technique was required for efficient use of multi-trade prefabrication in design, lifting and construction phase. In design phase, component level of BIM library was needed for manufacturing; and in lifting phase, BIM-based site logistics process was required. Also in construction phase, laser scanning was implemented for gathering shape and geometry of the wall and slab that were attached to multi-trade prefabrication module.

  • PDF

Experimental Verification on the Structural Performance of Reinforced Concrete Slabs Rigidly Connected by Steel Bar Injection (삽입철근을 사용한 강접합 철근콘크리트 슬래브의 구조 성능에 대한 실험 검증)

  • Kim Sang Sik;Choi Kwang Ho;Lee Jung-Yoon;Choi Ik Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.465-468
    • /
    • 2004
  • The first thing in remodelling of an apartment is the enlargement of living area, which is usually attained through extending balcony or corridor to the outside of the building. As a reasonable solution to the extension of floor a method of rigid connection in which steel bars are injected into the existing slab and concrete of newly building slab is installed with proper reinforcement is proposed in this research. To verify the structural performance of the method bending tests have been carried out for seven slab specimens.

  • PDF