• 제목/요약/키워드: Buffer strips

검색결과 14건 처리시간 0.028초

Estimation of the Pollutant Removal Efficiency in a Buffer Strip Using a SWAT Model

  • Lee, Eun-Jeong;Choi, Kyoung-Sik;Kim, Tae-Geun
    • Environmental Engineering Research
    • /
    • 제16권2호
    • /
    • pp.61-67
    • /
    • 2011
  • The water quality from nonpoint source run off results from different land use types has been studied. The construction of a buffer strip is one method of nonpoint source pollutant control. The Soil and Water Assessment Tool (SWAT) model has been applied to estimate the pollutant removal through the buffer strip. When the non-business land has been changed into grass to form a buffer-strip, the change of land use effects the results of the model according to measures of the water quality. The data from a water level station within the watershed in the years 2006 and 2007 was used for calibration and validation of the model. Under the rainfall conditions in 2007, the removal rates of SS, BOD, TN, TP were 11.5%, 9.5%, 1.2%, and 4.5%, respectively. During the rainy days, the removal rates at the buffer strip were 92.3% of SS, 91.2% of BOD, 82.4% of TN, and 83.5% of TP. The pollutants from nonpoint sources were effectively removed by over 80% as they passed through the buffer strips. Rainfall resulted in soil erosion, which led to an increase in the SS concentration, therefore, the construction of buffer strips protected the streams from SS inflows. Since TN concentrations are affected by the inflows of ground water and the N concentration of the rainfall, the removal rate of TN was relatively lower than for the other pollutants.

Parallel Generation of NC Tool Paths for Subdivision Surfaces

  • Dai Junfu;Wang Huawei;Qin Kaihuai
    • International Journal of CAD/CAM
    • /
    • 제4권1호
    • /
    • pp.47-53
    • /
    • 2004
  • The subdivision surface is the limit of recursively refined polyhedral mesh. It is quite intuitive that the multi-resolution feature can be utilized to simplify generation of NC (Numerical Control) tool paths for rough machining. In this paper, a new method of parallel NC tool path generation for subdivision surfaces is presented. The basic idea of the method includes two steps: first, extending G-Buffer to a strip buffer (called S-Buffer) by dividing the working area into strips to generate NC tool paths for objects of large size; second, generating NC tool paths by parallel implementation of S-Buffer based on MPI (Message Passing Interface). Moreover, the recursion depth of the surface can be estimated for a user-specified error tolerance, so we substitute the polyhedral mesh for the limit surface during rough machining. Furthermore, we exploit the locality of S-Buffer and develop a dynamic division and load-balanced strategy to effectively parallelize S-Buffer.

Application of Remote Sensing and GIS to the evaluation of riparian buffer zones

  • Ha, Sung-Ryong;Lee, Seung-Chul;Ko, Chang-Hwan;Seo, Se-Deok;Jo, Yun-Won
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.436-440
    • /
    • 2006
  • Diffuse pollution has been considering as a major source of the quality deterioration of water resources. The establishment of riparian vegetation strips of buffers along those areas of water bodies is used to reduce the threat of diffuse pollution. Remote sensing offers a means by which critical areas could be identified, so that subsequent action toward the establishment of riparian zones can be taken. Even though the principal purpose of this research comes from the feasibility of the imagery of KOMPSAT-2 satellite, Landsat TM satellite data, which has 7 bands, are used to characterize the land cover for the study area on the behalf of KOMPSAT-2. This investigation focuses on the assessment of the existing riparian buffer zones for a portion of the upper Geum river watershed from the viewpoint of pollution mitigation by riparian vegetation strip establishment. Through comparing the delineation of riparian buffer zones developed with the existing zones established by the government, we can find the critical distortion points of the existing riparian buffer zone.

  • PDF

Assessment of riparian buffers for reducing pollution according to land-cover pattern using RS and GIS

  • Ha, Sung-Ryong;Lee, Seung-Chul;Ko, Chang-Hwan;Jo, Yun-Won
    • 대한원격탐사학회지
    • /
    • 제22권5호
    • /
    • pp.445-449
    • /
    • 2006
  • Diffuse pollution has been considering as a major source of the quality deterioration of water resources. The establishment of riparian vegetation strips or buffers along those areas of water bodies is used to reduce the threat of diffuse pollution. Remote sensing offers a means by which critical areas could be identified, so that subsequent action toward the establishment of riparian zones can be taken. On the behalf of KOMPSAT-2 satellite imagery as a high resolution spatial data, Landsat TM satellite data are used to aquire the land cover for the riparian buffers studied. This investigation aims to assess the riparian buffers established on the upper Geum river as a pollution mitigation. Through comparing the delineation of riparian buffer zones developed with the existing zones established by the government, we can find the critical distortion points of the existing riparian buffer zone.

Two-dimensional gel Electrophoresis of Helicobacter pylori for Proteomic Analysis

  • Jung, Tae-Sung;Kang, Seung-Chul;Choi, Yeo-Jeong;Jeon, Beong-Sam;Park, Jeong-Won;Jung, Sun-Ae;Song, Jae-Young;Choi, Sang-Haeng;Park, Seong-Gyu;Choe, Mi-Young;Lee, Byung-Sang;Byun, Eun-Young;Baik, Seung-Chul
    • 대한미생물학회지
    • /
    • 제35권2호
    • /
    • pp.97-108
    • /
    • 2000
  • Two-dimensional gel electrophoresis (2-DE) is an essential tool of proteomics to analyse the entire set of proteins of an organism and its variation between organisms. Helicobacter pylori was tried to identify differences between strains. As the first step, whole H. pylori was lysed using high concentration urea contained lysis buffer [9.5 M Urea, 4% CHAPS, 35 mM Tris, 65 mM DTT, 0.01% SDS and 0.5% Ampholite (Bio-Rad, pH 3-10)]. The extract ($10\;{\mu}g$) was rehydrated to commercially available immobilised pH gradient (IPG) strips, then the proteins were separated according to their charges as the first dimensional separation. The IPG strips were placed on Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis (SDS-PAGE) to separate according to molecular mass of the proteins as the second dimension. The separated protein spots were visualised by silver staining in order to compare different expression of proteins between strains. Approximately 120 spots were identified in each mini-protein electrophoresised gel, furthermore about 65 to 75 spots were regarded as identical proteins in terms of pI value and molecular weight between strains used. In addition, distinct differences were found between strains, such as 219-1, Y7 and Y14, CH150. Two representative strains were examined using strips which had pH range from 4 to 7. This strips showed a number of isoforms which were considered large spots on pH range 3-10. Furthermore, the rest of spots on pH 4-7 IPG strips appeared very distinctive compared to broad range IPG strips. 2-DE seems to be an excellent tool for analysing and identifying variations between H. pylori strains.

  • PDF

BMP 기법에 따른 용담호 호수수질 개선효과 (The effects on improvement of Water Quality in Yong-dam Reservoir according to the BMP techniques)

  • 김순택;김태근
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.239-243
    • /
    • 2008
  • 본 연구는 용담호 유역을 대상으로 BMP 기법 중 하나인 수변구역이 호수수질의 개선효과를 규명하였다. 용담호의 수변구역 조성은 호수주변 1km, 금강본류 양안 500m로 지정되었고, 지정된 수변구역으로 인해 개발이 억제되며, 비점오염물질의 원인이 되는 논, 밭, 과수원, 기타재배지, 기타나지를 초지로 변경하여 호수로 유입되는 비점오염원을 제한한다. 저감되는 비점오염물질량을 정량화 하기 위하여 유역모형인 SWAT 모형으로 호수로 유입되는 부하량의 감소를 산정하였고, 감소된 유입부하량을 호수모형인 WASP 모형에 연계하여 개선된 호수수질을 정량화 하였다.

  • PDF

요 중 백혈구를 측정하기 위한 새로운 진단 시험지 개발에 관한 연구 (Development of Novel Diagnostic Testing Strips for Measuring Leukocyte Levels in Urine)

  • 박수민;박정오;장원철
    • 대한화학회지
    • /
    • 제43권1호
    • /
    • pp.104-109
    • /
    • 1999
  • 백혈구는 인체가 세균이나 바이러스에 감염되면 그 숫자가 증가하게되고 특히 요 중에 백혈구가 검출되면 비뇨기계나 생식기계의 감염을 의심하게 되어 이 계통의 질병을 진단하고 예후를 판단하는데 중요한 지표가 된다. 이에 본 연구에서는 백혈구내의 에스터라제의 활성을 측정함으로써 간접적으로 백혈구의 수를 측정하기 위하여 pentyl-3-thiophene-carboxlyate(PTC), pentyl-8-quinolinecarboxylate(PQC), 2-phenyl-4(N-tosylalanyloxyl)-thiazole(PTT)의 에스테르 기질을 합성하였고 각 기질을 이용하여 백혈구 검출용 시험지를 제조하여 요 중의 백혈구를 측정하였다. 이 세 가지 기질을 사용하여 백혈구 측정을 한 결과 0.5% borate 완충용액 pH 8.0, 기질 0.03%, 0.1∼0.8% PVP 안정제, 1% decanol의 구성비로 만들어진 PTT 시험지의 반응 색상이 다른 기질에 비교하여 안정하며 표준 비색표에 의한 육안적인 감별은 물론 요 화학 자동분석기에서의 응용성이 좋았다.

  • PDF

분포형 유역모델을 이용한 식생여과대의 오염부하 저감효과 분석 (Evaluation of Pollution Loads Removal Efficiency of Vegetation Buffer Strips Using a Distributed Watershed Model)

  • 박민혜;조홍래;구본경
    • 환경영향평가
    • /
    • 제25권6호
    • /
    • pp.369-383
    • /
    • 2016
  • 본 연구에서는 강원도 평창군 대관령면에 위치한 산지초지와 초지의 말단에 조성한 식생여과대(Vegetation Buffer Strip, VBS)에 분포형 유역모델 CAMEL을 적용하였다. 그리고 이를 통해 확보한 매개변수를 초지와 식생여과대로 구분한 다수의 시험격자에 적용하여 다양한 인자들에 의한 식생여과대 오염부하 저감효과를 평가하였다. 시험격자를 이용한 시나리오 모의결과, 식생여과대에서 강우의 직접유출량은 식생여과대 폭이 넓어질수록 감소하는 것으로 나타났으며, 전반적으로 경사가 높을수록 오염물질의 저감효율은 낮아지는 것으로 나타났다. 유사의 경우, 식생여과대 폭에 따른 저감효율은 전반적으로 큰 차이를 보이지 않았다. TOC와 TN의 경우, 시험격자의 경사가 $10^{\circ}$, $20^{\circ}$일 때, 식생여과대 폭에 따른 저감효율은 큰 차이를 보이지 않았으나, 경사가 $30^{\circ}$일 때 식생여과대 폭이 좁을수록 높은 저감효율을 보였다. 반면, TP의 경우, 양토(Loam)에서의 저감효율은 전반적으로 높지만, 사양토(Sandy loam)에서는 경사가 $20^{\circ}$, $30^{\circ}$일 때 식생여과대 폭이 넓을수록 높은 저감효율을 보이는 것으로 분석되었다. 이는 TOC와 TN의 모의결과와는 상반되는 결과로 대부분 입자성 물질로 존재하는 인의 경우 지표면에서의 포착현상으로 인해 길이에 따라 비례적으로 저감효율이 높아지는 경향을 보이는 것으로 사료된다. 본 연구에서 구축한 모델은 향후 비점오염물질의 유출을 효과적으로 저감할 수 있는 식생여과대 조성을 위한 기준 등을 제안하는데 효과적으로 사용될 수 있을 것으로 기대된다.

축산분뇨 농지환원을 위한 적정관리방안 (Development of Guidelines for Animal Waste Land Application to Minimize Water Quality Impacts)

  • 홍성구
    • 한국농공학회지
    • /
    • 제44권5호
    • /
    • pp.136-146
    • /
    • 2002
  • Land application of manure compost is considered one of the widely-used animal waste management practices. Many livestock farms adopt composting for their animal waste disposal and apply the compost to crop fields. While standard rates have been established based on researches with respect to land application of manure compost recently, there have been few discussions on water quality impact of the application. Water quality impact should be taken into account in land applications of manure compost. In this study, management practices were proposed based on the investigation of water quality of leachate from manure compost under rainfall simulation, field studies, and monitoring runoff water quality from farm fields after land application of animal waste. The concentrations of major water quality parameters of the leachate were significantly high, whereas those of runoff from soils after tillage for soil incorporation, were not affected by the application based on a series of experiments. Runoff water from farm fields after land application also showed high concentrations of pollutants. Appropriate management practices should be employed to minimize pollutant loading from manure applied fields. Proposed major management practices include 1) application of recommended amounts, 2) proper tillage for complete soil and manure incorporation, 3) field management to prevent excessive soil erosion, 4) complete diversion of inflow into the field from outside, 5) implementation of vegetative buffer strips near boundaries, and 6) prevention of direct discharge of runoff water front fields Into streams.

Frequency Effects of Upstream Wake and Blade Interaction on the Unsteady Boundary Layer Flow

  • Kang, Dong-Jin;Bae, Sang-Su
    • Journal of Mechanical Science and Technology
    • /
    • 제16권10호
    • /
    • pp.1303-1313
    • /
    • 2002
  • Effects of the reduced frequency of upstream wake on downstream unsteady boundary layer flow were simulated by using a Wavier-Stokes code. The Wavier-Stokes code is based on an unstructured finite volume method and uses a low Reynolds number turbulence model to close the momentum equations. The geometry used in this paper is the MIT flapping foil experimental set-up and the reduced frequency of the upstream wake is varied in the range of 0.91 to 10.86 to study its effect on the unsteady boundary layer flow. Numerical solutions show that they can be divided into two categories. One is so called the low frequency solution, and behaves quite similar to a Stokes layer. Its characteristics is found to be quite similar to those due to either a temporal or spatial wave. The low frequency solutions are observed clearly when the reduced frequency is smaller than 3.26. The other one is the high frequency solution. It is observed for the reduced frequency larger than 7.24. It shows a sudden shift of the phase angle of the unsteady velocity around the edge of the boundary layer. The shift of phase angle is about 180 degree, and leads to separation of the boundary layer flow from corresponding outer flow. The high frequency solution shows the characteristics of a temporal wave whose wave length is half of the upstream frequency. This characteristics of the high frequency solution is found to be caused by the strong interaction between unsteady vortices. This strong interaction also leads to destroy of the upstream wake strips inside the viscous sublayer as well as the buffer layer.