• Title/Summary/Keyword: Bubble pulse

Search Result 33, Processing Time 0.021 seconds

Quantitative Evaluation for Improvement Effects of Performance After Mechanical Rehabilitation Treatments on Agricultural Groundwater Well (농업용 관정의 기계적 처리 이후 성능 개선 효과의 정량적 평가 사례)

  • Song, Sung-Ho;Lee, Byung-Sun;An, Jung-Gi
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.4
    • /
    • pp.42-49
    • /
    • 2016
  • Step-drawdown pumping tests for identifying the improvement of groundwater well performance after rehabilitation treatments were conducted in three longstanding wells. Three selective mechanical treatment methods including power bubble, high-voltage electric pulse, and air surging were applied to these wells and the applicability of these methods to secure additional groundwater resources were evaluated quantitatively. Commonly, drawdown at final stage of stepdrawdown pumping tests after rehabilitation decreased by as much as 0.61~0.70 meters compared to those before rehabilitation. In addition, final specific drawdown values of three wells increased from 9% to 14% after rehabilitation. Formation loss coefficient and well loss coefficient decreased to 6.1% and 60.6%, respectively, indicating some clogging materials by precipitation/corrosion/microbe within pores of aquifer materials, gravel packs, and screens were effectively removed by applied methods. Decrease of formation loss coefficient was higher in the well applied by the power bubble method meanwhile high-voltage electric pulse method demonstrated the higher decrease of well loss coefficient. Additionally secured groundwater amounts after rehabilitation ranged from 23.3 to 32.1 m3/day, which account for 8~16% of initially developed pumping rates of the wells. From the results of this study, the effective selection of rehabilitation treatments considering aquifer characteristics are expected to contribute to secure groundwater resources for irrigation as well as to plan systematic management program for groundwater resources in rural area.

A Visual Study on Nucleate Boiling Phenomena in a Closed Two-Phase Thermosyphon (밀폐형 2상 열사이폰내의 비등현상에 관한 가시화 연구)

  • 강환국;오광헌;김철주;박이동;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.185-198
    • /
    • 1995
  • This is an experimental study conducted to visualize the nucleate boiling phenomena and flow regimes occurring inside the liquid pool in a closed two-phase thermosyphon. To meet this purpose, an annular-type thermosyphon was designed and manufactured using a glass tube and a stainless steel tube, being assembled axisymmetrically. The heat to be supplied to the working fluid is generated within a very thin layer of stainless steel tube wall by applying a high frequency electromagnetic field through the induction coil, axisymmetrically set around the evaporator zone. Some important results were as follows ; 1) Considering the structural complexity of the tested thermosyphon, it showed good performance for the range of heat flux 2< q" <25kW/$m^2$ and saturation vapor pressure, 0.1<Pv<1.1bar 2) different type of nucleating boiling regimes were observed as described below, -Pulse boiling regime : Flow pattern changed cyclically with time during 1 cycle of pulse boiling process. The onset of Nucleation was followed by expulsive growing of vapor bubble, resulting in the so called blow-up phenomenon, massive expulsion of large amount of liquid around the bubble. -Transient : Some spherical vapor bobbles were observed growing out from 2~3 nucleating sites, that was dispersed at the lower part of the heated tube wall in the liquid pool. But the rest upper region above the nucleating sites were filled with churns or bubbles of vapor. -Continuous nucleate boiling regime : The whole zone of evaporator was filled with lots of spherical vapor bubbles, and the bubbles showed tendency to decrease in diameter as the heat flux increased.ased.

  • PDF

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

Electric current control of creation and annihilation of sub-100 nm magnetic bubbles examined by full-field transmission soft X-ray microscopy

  • Je, Soong-Geun;Jung, Min-Seung;Im, Mi-Young;Hong, Jung-Il
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1201-1204
    • /
    • 2018
  • The effect of electric current pulses on a sub-100 nm magnetic bubble state in a symmetric Pt/Co multilayer was directly observed using a full-field transmission soft X-ray microscope (MTXM). Field-induced evolution of the magnetic stripe domains into isolated bubbles with their sizes down to 100 nm was imaged under varying external magnetic fields. Electric current pulses were then applied to the created magnetic bubbles, and it was observed that the bubbles could be either created or annihilated by the current pulse depending on the strength of applied magnetic field. The results suggest that the Joule heating plays a critical role in the formation and/or elimination of the bubbles and skyrmions. Finally, the schematic phase diagram for the creation and annihilation of bubbles is presented, suggesting an optimized scheme with the combination of magnetic field and electric current necessary to utilize skyrmions in the practical devices.

Electric Spark System as Underwater Acoustic Source - I. Pressure pulses from low electric energy - (수중음원으로써의 전기방전시스템- I. 낮은 전기에너지로부터의 음압펄스 -)

  • Kim, Sung-Boo;Kim, Sang-Han
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.32-35
    • /
    • 1996
  • The pressure pulses generated from the underwater electric spark system ranged from 0.4 to 1.6kJ are measured with the variation of source depth and range. The characteristics of pressure pulses obtained through this experiment continue to show the same electric energy and depth dependence previously reported, but two particular phenomena are observed. First, it is observed that the peak pressure of the 1st bubble pulse induced from implosion is higher than that of the initial shock wave, which is particularily apparent to high electric energy more than 10kJ previous studies. Second, it has been reported that the energy ratio (potential energy of bubble/intrinsic energy of source) has some tendency to "droop" on the low electric energy as 0.02 for 5kJ and 0.01 for 1kJ but the results of the present experiment show that it continues to have the ratio of 0.01 near 1kJ again.

  • PDF

The Effect of Reaction Temperature and Volume in the Sonolysis of 1,4-Dioxane (1,4-Dioxane의 초음파 처리시 반응 온도와 부칙의 영향)

  • Son, Hyun-Seok;Choi, Seok-Bong;Eakalak, Khan;Zoh, Kyung-Duk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1114-1122
    • /
    • 2005
  • This research investigates the effects of sonication mode, reaction temperature and volume on sonolysis of 1,4-dioxane in order to increase the degradation efficiency and kinetics. The degradation efficiency in case with pulse mode was about 10 % higher than that in case with continuous mode. The degradation profiles in both cases, which were performed without the control of reaction temperature and in 1000 mL, were composed of three steps. However, 1,4-D was mainly degraded in the initiation step as the first portion and the acceleration step as the second portion. The initial step agreed with zero-order expression well, while the acceleration step could be fitted with pseudo 1st-order expression. The kinetic model in case with $5^{\circ}C$ and 300 mL conformed to pseudo 1st-order, while that in cases with $10^{\circ}C$ to $40^{\circ}C$ agreed with zero-order expression. The degradation efficiency and profile of 1,4-D in the experiment with $20^{\circ}C$ and 300 mL was higher and simpler than that in case with $20^{\circ}C$ and 1000 mL. The reaction temperature and volume influence bubble intensity, which was produced in sonication. The increase of bubble intensity induced to augment the production of OH radical in sonication.

Self-sensing measurement of piezo inkjet and its Applications (피에조 잉크젯의 셀프 센싱 검출 및 응용)

  • Kwon, Kye-Si;Kim, Wou-Sik;Kim, Sang-Il;Shin, Seung-Joo;Kim, Seong-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.366-372
    • /
    • 2007
  • Self-sensing measurement of piezo inkjet and its application are discussed. The pressure wave inside the inkjet dispenser was measured by current measurement due to self-sensing capability of PZT. The pressure wave measured from current was verified by commercially available laser vibrometer. Here, two applications using self-sensing signal were discussed: waveform design for high speed jetting and condition monitoring. For waveform design, two pulse waveform was designed based on self-sensing signal such that the pressure wave after droplet formation can be minimized. For condition monitoring, self-sensing signal was shown to be effective in detecting air bubble trapped in inkjet printhead.

  • PDF

Tungsten Wire Micro Electrochemical Machining with Ultra Short Pulses (텅스텐 와이어 초단 펄스 미세 전해가공)

  • Shin, Hong-Shik;Kim, Bo-Hyun;Chu, Chong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.6
    • /
    • pp.105-112
    • /
    • 2007
  • Tungsten wire micro electrochemical machining (W-wire micro ECM) with ultra-short pulses enables precise micro machining of metal. In wire micro ECM, platinum wire has been used because it is electrochemically stable. However, the micro metal wire with low strength is easily deformed by hydrogen bubbles which are generated during the machining. The wire deformation decreases the machining accuracy. To reduce the influence of hydrogen bubbles, in this paper, the use of tungsten wire was investigated. To improve machining accuracy, suitable pulse conditions which affect generation of bubbles were also investigated. The tungsten wire micro ECM can be applied to the fabrication of various shapes. Using this method, various micro-parts and shapes were fabricated.

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

Role of Liquid Vaporization in Liquid-Assisted Laser Cleaning (액막 보조 레이저 세척에서 액체 기화의 역할)

  • Lee, Joo-Chul;Jang, Deok-Suk;Kim, Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.2
    • /
    • pp.188-196
    • /
    • 2003
  • Liquid-assisted cleaning technology utilizing a nanosecond laser pulse is effective for removing submicron particulates from a variety of solid substrates. In the technique, saturated vapor is condensed on a solid surface to form a thin liquid film and the film is evaporated explosively by laser heating. The present work studies the role of liquid-film evaporation in the cleaning process. First, optical interferometry is employed for in-situ monitoring the displacement of the laser-irradiated sample in the cleaning process. The experiments are performed for estimating the recoil force exerted on the target with and without liquid deposition. Secondly, time-resolved visualization and optical reflectance probing are also conducted for monitoring the phase-change kinetics and plume dynamics in vaporization of thin liquid layers. Discussions are made on the effect of liquid-film thickness and dynamics of plume and acoustic wave. The results confirm that cleaning force is generated when the bubble nuclei initially grow in the strongly superheated liquid.