• 제목/요약/키워드: Broken bar

검색결과 58건 처리시간 0.024초

소의 제4위전위증 교정을 위한 봉봉합법 (Bar Suture for the Treatment of Bovine Abomasal Displacement)

  • 조명래
    • 한국임상수의학회지
    • /
    • 제9권1호
    • /
    • pp.261-266
    • /
    • 1992
  • Surgical treatment was performed in 507 heads out of 1078 dairly cows which were diagnosed as abomasal displacement. Out of 507 heads. bar suture was performed in 280 heads. Twelve heads out of 280 heads(4.9%) recurred. Incorrective suture of the reticulum or pylorus instead of abomasum occurred in 3 cows. The cows in which abdominal wall was sutured but the suture was not inserted into the abomasum were 4 heads. The cows in which bar was broken are 4 heads. A cow suffered peritonitis after bar suture. Bar suture technique is thought to be a good method as a first choice for the correction of abomasal displacement.

  • PDF

차압식 유량계를 실장을 위한 Single Capacitive Type Differential 압력 센서 개발 (Fabrication of Single Capacitive type Differential pressure sensor for Differential Flow meter)

  • 신규식;송상우;이경일;이대성;정재필
    • 마이크로전자및패키징학회지
    • /
    • 제24권1호
    • /
    • pp.51-56
    • /
    • 2017
  • 최근 계측기의 소형화, 전자화에 따라 차압식 유량계의 경우 기존에 기계가공을 통해 개발하던 센서부를 전자식 MEMS 차압센서로 대체하려는 많은 노력이 있으나, MEMS 차압센서의 경우 고압이 인가시 실리콘 다이아프램의 파괴 및 센서의 접합부의 파괴가 발생하는 문제점이 있다. 따라서 본 논문에서는 proof pressure 이상의 압력에서 센서의 다이아프램이 파괴되지 않는 구조를 제안하였으며, 그에 따른 차압식 압력센서를 설계 및 제작하였다. 센서 동작압력(0-3 bar)의 3배 이상의 압력에서 센서의 동작특성을 평가하였다. 개발된 센서는 $3.0{\times}3.0mm$이며, 0~3 bar 사이의 압력에서 LCR meter (HP 4284a)로 측정한 결과 3.67 pF at 0bar, 5.13 pF at 3 bar를 나타내었으며, 센서의 동작압력(0-3 bar)에서 0.37%의 hysteresis를 나타내는 압력센서를 개발하였다.

가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향 (Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process)

  • 김준현;문백수;박종수;조윤호;김진호
    • 멤브레인
    • /
    • 제23권6호
    • /
    • pp.460-468
    • /
    • 2013
  • 가압식 MF공정의 전처리공정으로 침전지가 없는 혼화/응집공정에서 적정응집제 투입농도선정 및 유기물 제거성능을 평가하였다. 전처리 공정에서 생성된 플럭이 가압펌프의 임펠러에 의해 해체됨을 확인하였으며 원수탁도가 10 NTU 이하로 유입이 될 때, 혼화/응집조와 펌프후단에서 플럭형성을 위한 최적응집제 투입량은 4 mg/L (as PACl 17%)이었다. 이때의 DOC 제거율은 평균 43%이었으며, 응집제투입량을 계속적으로 증가시켜 8 mg/L (as PACl 17%)로 투입을 하였을 때, DOC 제거율은 평균 48%를 나타내어 제거율은 크게 개선되지 않았다. 전처리가 없는 PVDF 가압식 MF공정의 TMP는 0.54 bar에서 운영이 되었으며, 혼화/응집 전처리 공정을 적용하여 운영 시 TMP는 0.41 bar로 안정적인 운영이 가능하였다.

축방향 누설자속 측정에 의한 유도전동기의 회전자 결함검출에 관한 연구 (A Study of Rotor Fault Detection for the Induction Motor Using Axial Leakage Magnetic Flux)

  • 신대철;김영환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.132-137
    • /
    • 2006
  • 유도전동기에 대한 결함 검출의 도구로서 축방향 누설자속 측정 방법을 사용할 수 있는가를 평가하고 전동기고장 검출에 관한 진단 알고리즘을 개발하기 위한 회전자에 관한 2번째 논문이다. 결함 검출을 위해 운전 중인 전동기의 끝단에 설치된 자속코일 센서로 누설자속 신호를 수집하며 전동기의 각종 결함을 검출하기 위해 시간과 주파수 영역에서 신호를 분석하였다. 센서 신호 형상이 전동기 각각의 결함에 대해 시간과 주파수 영역에서 해석하였다. 전동기의 회전자 관련 격함인 회전자봉 파손, 단락환 파손 및 회전자 편심이 축방향에서 측정된 고해상도의 스펙트럼으로부터 검출할 수 있는 방법을 확인하였다. 누설자속 스펙트럼으로부터 특정 주파수와 회전자봉 통과주파수의 측파대를 분석함으로서 회전자 결함을 검출하는 방법을 알았다. 또 유도전동기에 대하여 축방향 누설자속 측정을 위한 최적의 자속코일센서 및 측정시스템을 검증하고 회전자 결함을 검출하기 위한 방법을 개발하였다.

유도전동기 로터바의 손상과 인버터 제어특성에 관한 연구 (A Study on The Broken Rotor Bars in Induction Motor and The Controll Characteristics in Inverter)

  • 김근웅;권중록;이잠재;최경수;이호석;장서건
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.464-466
    • /
    • 2001
  • The advantage of the squirrel cage induction motor is the brushless rotor. This advantage for operation and maintenance turns out to be a disadvantage for the detection of the cage rotor bar and endring defects, which means that the detection of cage faults is due to the measurement and analysis of only the stator input signals. The monitoring task in an inverter drive is complicated mainly because the voltage and current waveforms are nonsinusoidal and the high dv/dt values from fast switching inverterd distort the measurements. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA).

  • PDF

CPM Bar Chart 기법을 활용한 일정계획 (CPM Bar Chart Technique for Construction Scheduling)

  • 김경환;김수유;김재준
    • 한국건설관리학회논문집
    • /
    • 제5권5호
    • /
    • pp.135-142
    • /
    • 2004
  • 본 연구에서는 바차트(bar chart) 기법과 CPM 기법의 장점을 결합한 CPM bar chart(CBC) 기법을 제시한다. CBC는 기존의 fenced bar chart(FBC)의 장점을 유지하면서 단점을 보완한 것으로, 작업 관계를 나타내는 fence에 방향성을 부여함으로써, 기존 FBC에서 상당한 혼란을 유발하는 fence의 분리과정 없이 작업들의 관계를 표현할 수 있다. 또한, fence의 분리를 파악하기 위해 더미작업(dummy activity)을 확인하는 과정이 생략되어 보다 손쉽게 작성할 수 있는 장점도 있다. 바차트의 간결성을 유지하면서 CPM의 네트워크 논리 표현이 가능해짐에 따라, CBC는 다양한 프로젝트 참여자들 간의 원활한 의사소통에 기여하리라 예상된다. 또한, resource constrained scheduling, resource leveling, 작업 분리가 고려된 일정 조정, 공기 지연 분석 등의 CPM 기법에 기초한 다양한 일정 계획 및 관리에도 적용이 용이하여, 실무뿐만이 아니라 공정관리 교육과정에서도 활용성이 높으리라 기대된다.

Comparative study on dynamic properties of argillaceous siltstone and its grouting-reinforced body

  • Huang, Ming;Xu, Chao-Shui;Zhan, Jin-Wu;Wang, Jun-Bao
    • Geomechanics and Engineering
    • /
    • 제13권2호
    • /
    • pp.333-352
    • /
    • 2017
  • A comparison study is made between the dynamic properties of an argillaceous siltstone and its grouting-reinforced body. The purpose is to investigate how grout injection can help repair broken soft rocks. A slightly weathered argillaceous siltstone is selected, and part of the siltstone is mechanically crushed and cemented with Portland cement to simulate the grouting-reinforced body. Core specimens with the size of $50mm{\times}38mm$ are prepared from the original rock and the grouting-reinforced body. Impact tests on these samples are then carried out using a Split Hopkinson Pressure Bar (SHPB) apparatus. Failure patterns are analyzed and geotechnical parameters of the specimens are estimated. Based on the experimental results, for the grouting-reinforced body, its shock resistance is poorer than that of the original rock, and most cracks happen in the cementation boundaries between the cement mortar and the original rock particles. It was observed that the grouting-reinforced body ends up with more fragmented residues, most of them have larger fractal dimensions, and its dynamic strength is generally lower. The mass ratio of broken rocks to cement has a significant effect on its dynamic properties and there is an optimal ratio that the maximum dynamic peak strength can be achieved. The dynamic strain-softening behavior of the grouting-reinforced body is more significant compared with that of the original rock. Both the time dependent damage model and the modified overstress damage model are equally applicable to the original rock, but the former performs much better compared with the latter for the grouting-reinforced body. In addition, it was also shown that water content and impact velocity both have significant effect on dynamic properties of the original rock and its grouting-reinforced body. Higher water content leads to more small broken rock pieces, larger fractal dimensions, lower dynamic peak strength and smaller elastic modulus. However, the water content plays a minor role in fractal dimensions when the impact velocity is beyond a certain value. Higher impact loading rate leads to higher degree of fragmentation and larger fractal dimensions both in argillaceous siltstone and its grouting-reinforced body. These results provide a sound basis for the quantitative evaluation on how cement grouting can contribute to the repair of broken soft rocks.

전기신호를 이용한 전동기 온라인 고장진단 (Online Fault Diagnosis of Motor Using Electric Signatures)

  • 김낙교;임정환
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1882-1888
    • /
    • 2010
  • It is widely known that ESA(Electric Signature Analysis) method is very useful one for fault diagnosis of an induction motor. Online fault diagnosis system of induction motors using LabVIEW is proposed to detect the fault of broken rotor bars and shorted turns in stator. This system is not model-based system of induction motor but LabVIEW-based fault diagnosis system using FFT spectrum of stator current in faulty motor without estimating of motor parameters. FFT of stator current in faulty induction motor is measured and compared with various reference fault data in data base to diagnose the fault. This paper is focused on to predict and diagnose of the health state of induction motors in steady state. Also, it can be given to motor operator and maintenance team in order to enhance an availability and maintainability of induction motors. Experimental results are demonstrated that the proposed system is very useful to diagnose the fault and to implement the predictive maintenance of induction motors.

기전연성계 해석을 이용한 단상유도전동기의 회전자 결함진단에 관한 연구 (Fault Diagnosis of Rotor Bars in a Single Phase Induction Motor Monitoring Electromechanical Parameters)

  • 박상진;장정환;장건희;이용복;김창호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.802-808
    • /
    • 2000
  • This paper characterizes the electromechanical parameters due to the fault of rotor bars in a squirrel cage induction motor. Simulation is performed to investigate how broken rotor bars have effect on them by solving the time-stepping finite element equation coupled with magnetic field equation, circuit equation and mechanical equation of motion. It shows that the asymmetry of magnetic flux due to the broken rotor bar introduces the beating phenomenon in time domain and the sideband frequencies in frequency spectra, respectively, to the stator current, torque, speed, magnetic force and vibration of a rotor. However, vibration of a rotor would be the most effective monitoring parameters to detect the faults of rotor bars.

  • PDF

MPM을 이용한 고압전동기 운전중 상태 평가 (On-Line Assessment of High Voltage Motor Condition using the Motor Performance Monitor)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제57권9호
    • /
    • pp.1589-1593
    • /
    • 2008
  • The condition of a high voltage motor was monitored with the motor performance monitor (MPM) at the motor control center. The MPM detected defects in the rotor bar and end ring and input power according to motor and load conditions. The assessment of the condition of a coal pulverizer motor indicated it was clearly in good condition in terms of the rotor bars, over voltage, and motor performance. However, the side bands at frequency, 56.48 Hz indicated existence of rotor end-ring fault. The large torque ripple indicated abnormal operating conditions. After visual inspection, it has been observed that an impeller blade of the circulating water pump was broken off causing the irregular torque pattern.