• Title/Summary/Keyword: Breathing phase

검색결과 53건 처리시간 0.025초

병원 전 단계 응급의료서비스 개선을 위한 구급활동일지 (Analysis of Prehospital Care Report for Improving Emergency Service at Prehospital Phase)

  • 최길순;김윤경
    • 한국응급구조학회지
    • /
    • 제11권3호
    • /
    • pp.163-174
    • /
    • 2007
  • Purpose : This study analyzes prehospital care report of emergency service at prehospital stage, examines characteristics of activities of 119 paramedics and its users and aims to provide help for improving emergency system in future. Methods : Data collected were 119 prehospital care report and hospital records with 7,160 patients to emergency room by 119 ambulance from Jan. 1 to Dec. 31, 2006 and percentage and frequency of the data were obtained. Results : 1) Use of emergency room by 119 ambulance was increased in summer and autumn such as August(9.1%), September(11.2%) and October(13.5%) and it was more frequently used on Monday(17.3%), Saturday(17.2%) and Friday(16.1%) by telephone(98.6%). 2) Using emergency room was most in over sixties(51.8%), men(64.2%), community residents (78.3%), by report of family(50.3%) and at '09:01~12:00'(16.5%). 3) Symptoms of emergency room users included headache, chest pain, stomachache, lumbago and others as 40.6% and places where patients were found were at home(60.1%) due to chronic internal diseases at 49.2%. 4) Most of non-emergency patients(80.2%) arriving at hospital had normal pupil condition (88.4%) and clear consciousness(71.2%) and most of them left hospital after having first-aid treatment. 5) Physiological symptom tests evaluated by paramedics at prehospital stage included blood pressure(56.6%), pulse(22.9%), breathing(13.0%) and temperature(9.2%), and there was no SPo2 case. 6) Classification of severity by paramedics showed difference as emergency patients(18.0%) by paramedics and those(24.9%) by hospital. 7) First-aid treatments by paramedics at prehospital stage were promoting comfort(28.9%), hemostasis(7.7%), fixing cervical vertebrae(4.0%) and ensuring vein route(3.1%). 8) Selectors of medical agency were patients or guardians(86.2%) and emergency medical technicians(73.6%). Conclusion : To sum up the above research, it was found that percentage of using 119 ambulance by non-emergency patients was higher and paramedics performed basic first-aid treatment rather than professional first-aid treatment due to several conditions such as legal problems, range of allowance, etc. Therefore, it is considered that method to reduce frequency of ambulance by non-emergency patients and approaches to alleviate limitations of allowance of paramdeics to make them perform effective first-aid treatment at prehospital stage should be sought in the dimension of individual, organization and government.

  • PDF

Comparison on postural control between abdominal draw-in maneuver and abdominal expansion maneuver in persons with stroke

  • Choi, Ho-Suk;Shim, Yu-Jin;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.113-119
    • /
    • 2016
  • Objective: The effect of abdominal expansion maneuver (AEM) and abdominal draw-in maneuver (ADIM) on postural control in an unsupported position in stroke patients. Design: Randomized controlled trial. Methods: A total of 36 persons with hemiplegic stroke participated in this study. The subjects were randomly divided into an AEM experimental group (n=12), an experimental ADIM group (n=12), and a control group (n=12). We collected the general characteristics of all subjects and the pre-test results before the intervention and after 4 weeks of the intervention. The trunk stabilization training of the ADIM and AEM group were performed 15 minutes a day, 3 times a week for 4 weeks, and general physical therapy was performed 2 times a day, 30 minutes per session, 5 times a week for all three groups. The control group received joint mobilizations, muscle strengthening, endurance strengthening, and gait exercises along with treatment of the central nervous system, such as neuro-developmental treatment, mat, and gait training. The AEM is an inspiratory phase of tidal breathing expanding the lateral lower ribcage in a lateral direction with minimal superior movements of the chest. Then the lower abdomen expands and the navel moves in an anterior-caudal direction. The ADIM is a repeated contraction and relaxation of the anal sphincter during inspiration. The navel pulls the lower abdomen to the direction of the spine without the movement of the trunk and pelvis. Results: Before and after the interventions, medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area 95% was a statistically significant change in all three groups (p<0.05). The post-hoc test showed a significant improvement in medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area in the AEM group compared with the control group, and in the ADIM group compared with the control group (p<0.05). Conclusions: In conclusion, both AEM training and ADIM training are necessary interventions to maintain the independent sitting position according to the characteristics of the patient.

방사선치료용 선형가속기를 이용한 Gated Cone-Beam CT의 유용성 연구 (Study on the Validation of the Gated Cone-Beam Computed Tomography on Radiation Therapeutic Linear Accelerator)

  • 서정민;김찬형;박병석;박철수;장현철;김정대
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6932-6939
    • /
    • 2015
  • 환자의 호흡은 방사선치료에서 중요한 인자로 작용한다. 종양을 치료하는 방사선 치료용 선형가속기에서 시행하는 기존의 cone-beam CT에서는 호흡에 의한 움직임이 반영되지 않아 영상에 왜곡이 발생하여 정확하지 못한 영상 정보를 획득하였다. 본 연구는 호흡에 의한 움직임을 고려하고 특정 순간을 포착한 gating을 적용하여 획득한 back projection 영상을 이용하여 cone-beam CT 영상으로 재구성하였으며 기존의 방법과 비교하였다. 기존의 방법은 영상 왜곡도가 400%에 달하였으나, 본 연구에서 시행한 gating을 적용한 cone-beam CT는 약 2%에 불과하였다. 이에 본 연구는 호흡의 움직임을 반영한 영상유도 방사선치료의 방향과 평가 방법을 제시하였다.

응급실 내 의사와 간호사가 인식하는 병원 내 응급구조사의 업무인식도 (Emergency Medical Participants' recognition of The Emergency Medical Technicians' Job Awareness)

  • 배기숙;한송이
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2908-2914
    • /
    • 2013
  • 본 연구는 대전,충남 소재 대학병원에 근무하는 응급의료종사자 122명을 대상으로 병원 내 응급구조사를 조사하여 응급구조사의 역할과 법적 업무규정의 현실적 제고 및 병원 내 응급구조사의 업무에 관한 인식을 보다 명확히 하기 위한 기초자료를 제공 하고자 연구를 실시하였다. 연구 대상자들의 병원 내 응급구조사의 업무인식을 살펴본 결과, 전체 40문항에 대해 $3.23{\pm}0.67$점으로 나타나 병원 내 응급구조사에 대한 업무인식정도는 중간 보다 다소 높은 것으로 나타났다. 영역별로는 외상처치가 가장 높게 나타났으며, 약물투여가 가장 낮았다. 응급의료종사자가 응급구조사의 업무를 바르게 인식하게 하기 위해서는 응급구조사가 고유 업무와 역할을 충실히 해 낼 수 있어야 할 것이다. 그러므로 보다 명확한 교육과정이 이루어져야 하며 보다 명확한 업무가 법적으로 규정되어져야 한다. 응급구조사에 대한 홍보와 지속적인 모니터링이 필요할 것으로 사료된다.

The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

  • Bae, Jin Suk;Kim, Dong Hyun;Kim, Won Taek;Kim, Yong Ho;Park, Dahl;Ki, Yong Kan
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Methods and Materials: Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ${\leq}2cm$) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. Results: The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Conclusion: Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

방사능위해성평가 프로그램 RADCONS의 개발 및 적용 (Development and Application of Radiological Risk Assessment Program RADCONS)

  • 정효준;박미선;황원태;김은한;한문희
    • 환경영향평가
    • /
    • 제22권1호
    • /
    • pp.89-97
    • /
    • 2013
  • RADCONS Ver. 1.0 (RADiological CONSequence Assessment Program) was developed for radiological risk assessment in this study. A Gaussian plume model was used to analyze the fate and transport of radionuclides released into the air in case of accidents. Both single meterological data and time series meterological data can be used in RADCONS. To assess the radiological risk of the early phase after an accident, ED (Effective Dose) estimated by both deterministic and probabilistic approaches are presented. These EDs by deterministic and probabilistic will be helpful to efficient decision making for decision makers. External doses from deposited materials by time are presented for quantifying the effects of mid and late phases of an accident. A radiological risk assessment was conducted using RADCONS for an accident scenario of 1 Ci of Cs-137. The maximum of ED for radii of 1,000 meters from the accident point was 8.51E-4 mSv. After Monte-Carlo simulation, considering the uncertainty of the breathing rate and dispersion parameters, the average ED was 8.49E-4, and the 95 percentile was 1.10E-3. A data base of the dose coefficients and a sampling module of the meteorological data will be modified to improve the user's convenience in the next version.

영상변조 프로그램을 이용한 호흡 위상 간 종양의 움직임 특성 분석 (Analysis of Intrafractional Mass Variabilities Using Deformable Image Registration Program)

  • 조정희;김주호;서선열;한동균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.173-181
    • /
    • 2012
  • 본 연구의 목적은 호흡 위상을 고려한 4DCT 자료를 토대로 자동영상변조등록 프로그램인 MIMVista에서 계산한 최대강도투영 영상에서 폐종양의 발생위치와 유착여부에 따른 종양의 움직임 특성을 분석하고 3DCT 결과 값과 비교하였으며 호흡 위상 간 종양의 도심변화 등 기하학적 변형 특성를 분석했다. 분석결과 폐하부에 위치한 종양에서 Y축으로의 평균 도심 변화가 $7.32{\pm}6.88mm$로 가장 크게 나타났으며 HU값의 차이를 분석한 결과에서도 평균 $7.7{\pm}4.97%$로 가장 큰 차이를 보였다. 유착성 종양보다는 비유착성 종양에서 호흡 간 변화가 크게 나타났다. 3DCT 영상과 MIP 영상간에 종양 용적의 연관성을 분석한 결과 상관계수가 0.998로 매우 높게 나타났다. 종양의 기하학적 변화에 영향을 미치는 요인분석결과 종양의 위치와 유착여부가 큰 영향을 미치는 것으로 분석되었으나 횡격막의 움직임 정도에 따른 차이는 없었으며 환자 간 호흡 위상에 따른 편차가 매우 크기 때문에 종양의 움직임과 관련한 특정 경향성을 파악할 수는 없었다.

호흡 기반 사람과 사물 구분 가능한 FMCW 레이다 신호처리 프로세서의 설계 (Design of FMCW Radar Signal Processor for Human and Objects Classification Based on Respiration Measurement)

  • 이윤구;윤형석;김수연;허성욱;정윤호
    • 한국항행학회논문지
    • /
    • 제25권4호
    • /
    • pp.305-312
    • /
    • 2021
  • 보안 시스템에는 다양한 센서가 사용되고 있지만, 사생활 문제가 논란이 됨에 따라 레이다 센서가 대안으로 제시되고 있다. 그 중 PD (Pulse Doppler) 레이다는 짧은 펄스를 사용함으로써 수신부 복잡도가 증가하는 문제가 존재하나, FMCW (Frequency modulated continuous wave) 레이다는 그러한 제한이 적다는 장점이 있다. 그러나, FMCW 레이다는 2D-FFT (2-dimensional fast Fourier transform)를 사용하므로 기존의 센서에 비해서 상대적으로 높은 복잡도를 가지며, 정지해있는 표적에 대해 사람과 사물을 구분하기 어려운 단점이 있다. 따라서 본 논문에서는 1D-FFT와 위상 변화만으로 호흡 여부를 확인하여 사람과 사물을 구분할 수 있는 레이다 신호처리 프로세서의 설계 및 구현 결과를 제시한다. 제안된 신호처리 프로세서는 Verilog-HDL을 기반으로 설계하여 FPGA 디바이스에 기반하여 구현 및 검증하였다. LUT (Look up table) 6,425개, register 4,243개, 12,288개의 memory bit로 구현하여 92.1%의 정확도로 대상의 호흡 여부를 확인할 수 있음을 확인하였다.

호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study (Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy)

  • 박제완;김민수;엄기천;최성훈;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.25-33
    • /
    • 2021
  • 목 적 : 본 연구를 통해 호흡동조방사선치료(Respiratory Gated Radiation Therapy, RGRT)시 환자 호흡 속도에 따른 Trigger mode의 정확성과 유용성을 평가하고자 한다. 대상 및 방법 : 호흡 속도에 따른 Trigger mode의 정확성을 평가하기 위해 QUASARTM 호흡 움직임 팬텀에 3 mm의 기준 표지자(Fiducial marker, gold marker)를 삽입하여 본원 한달 동안 환자의 평균 호흡인 20 bpm(Breath per minute)을 기준으로 4DCT 촬영 후 정중앙(Median)에 위치한 표지자에 윤곽 묘사(Contouring)를 하였다. OBI(On Board Imager)가 장착된 Truebeam STxTM를 이용해 방사선조사 구간인 Gating window를 Lower threshold는 2.0 mm로 모든 측정 조건에서 고정시키고, Upper threshold를 최고 위상으로부터 각각 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, 3.0 mm로 바꿔가며 측정하였다. 위와 같은 조건에서 평균 호흡 속도인 20 bpm을 기준으로 10 bpm, 30 bpm, 40 bpm, 50 bpm, 60 bpm 호흡속도를 바꿔가며 방사선이 끊기는 순간인 'Once at beam off'로 5회 촬영하였다. 같은 방법으로 3일간 반복 촬영 후 각 속도 별 오차율을 비교하였다. 결 과 : 기준 호흡 속도 20 bpm에서 최고 위상으로부터 각각 1.0 mm, 1.5 mm, 2.0 mm, 2.5 mm, 3.0 mm Upper threshold에서 Trigger mode의 beam off시 차이는 3일간의 평균값으로 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, 1.66±0.06 mm이다. 기준 호흡 속도(20 bpm)대비 호흡 속도 변화에 따른 측정 결과는 최대 절대차이(Absolute Difference)의 경우 1일차, 2일차, 3일차 모두 3 mm Upper threshold에서 평균 0.81±0.08 mm로 차이가 확인되었다. 호흡 속도와 절대차이의 편차(Variation)에 대한 상관관계를 평가하기 위한 결정계수 R2는 3일 평균 수치로 각각 0.838, 0.887, 0.770, 0.850, 0.906로 확인되었다. 3일간의 Threshold 모든 변수에서 p-value는 설정 유의수준 0.05 이하로 차이유의를 확인하였다. 결 론 : 호흡동조방사선치료 시 Trigger mode를 이용하여 영상유도를 할 경우 기준 호흡 속도(20 bpm)에서의 Trigger mode의 오차율이 평균 ±0.04 mm 값으로 정확성과 유용성을 확인 할 수 있었다. 그러나 호흡 속도에 따른 부정확성(Uncertainty) 또한 발생할 수 있다는 것을 알 수 있었으며, 특히, 기준 호흡 속도 대비 느려지는 경우(< 20 bpm)보다 빨라지는 경우(> 20 bpm) 영상획득에 대한 부정확성은 커졌다. 따라서 사전 모의치료시의 호흡을 선별하고 호흡을 유지하기 위한 호흡교육과 치료 중 적극적인 실시간 모니터링(Monitoring)이 필요하다고 사료된다.

폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발 (Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT)

  • 윤경준;곽정원;조병철;송시열;이상욱;안승도;남상희
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.100-109
    • /
    • 2014
  • 정위신체방사선치료(SBRT)에서 환자의 호흡에 대한 정확한 치료위치의 확보는 필수적으로 고려되어야 하며 그 정확성에 관련하여 많은 연구들이 진행되어왔다. 본 연구에서는 실제 호흡에 의한 움직임과 실제 환자 폐의 형태를 고려한 팬텀실험으로 실제 치료에서 일어나는 임상적 상황을 모사함으로 호흡 동조 부피적조절회전 방사선치료(Volumeric Modulated Arc Therapy, VMAT) 기법을 이용한 폐부 SBRT의 정확성을 분석하는 방법을 제시하고자 하였다. SBRT을 받은 폐암 환자의 CT 영상을 기반으로 3D 프린터를 이용하여 치료부위와 유사하게 폐 팬텀을 제작하였고 환자 호흡과 동일하게 움직임을 재현할 수 있도록 $QUASAR^{TM}$ 호흡 동조 구동 팬텀(Modus Medical Devices, London, Canada)에 장착하여 호흡동조 VMAT에서의 2차원 선량 분포를 평가할 수 있는 시스템을 구축하였다. 폐 팬텀은 종양부위를 중심으로 2등분하여 EBT3 필름을 삽입하고 선량분포를 측정할 수 있도록 제작되었다. 비균질 조건에서의 선량계산의 정확성을 확인하기 위하여 균질한 플라스틱 팬텀과 제작된 비균질 폐 팬텀에서 Analytical Anisotropic Algorithm (AAA)와 AcurosXB (AXB) 두가지 알고리즘으로 선량계산을 하여 비교, 분석하였다. 움직임에 대한 치료의 정확성을 평가하기 위하여 호흡동조와 비 호흡동조의 경우, 그리고 움직임이 없는 조건에서 선량분포를 취득하여 치료계획 선량에 대한 감마지표를 분석하였다. 치료부위 GTV에서의 CT number는 실제 환자의 경우 78 HU를 나타내었고 모사된 폐 팬텀의 경우 92 HU를 나타내었다. 팬텀 내 폐 조직부분은 3D프린터로 적층하는 과정에서 격자구조의 형태를 이용하여 구현하였다. 측정된 필름선량은 AAA 알고리즘을 이용한 치료계획 선량에 대하여 움직이는 팬텀에서 호흡동조의 유무에 따라 3%/3 mm 감마지표 조건하에서 각각 88%와 78%의 감마합격률을 나타내었으며, 움직임이 없는 경우 95% 이상의 감마합격률을 보였다. AXB 알고리즘을 적용하였을 경우에는 모든 경우에서 98% 이상의 합격률을 나타내었다. 균질한 플라스틱 팬텀에 대하여 측정하였을 때 두가지 선량계산 알고리즘을 포함한 모든 조건에서 99% 이상의 감마합격률을 나타내었다. 선택된 환자의 호흡 진폭이 비교적 작고 inhale보다는 exhale에 더 오래 머무르는 호흡패턴 때문에 3%/3 mm 감마 기준에서는 호흡에 따른 차이가 거의 나타나지 않은 것으로 이해되었다. 선량계산의 정확성에서는 AAA 알고리즘을 적용하였을 때보다 AXB 알고리즘을 적용하였을 때가 균질과 비균질 환경에서의 선량 분포에 따른 감마 합격률의 차이가 적게 나타남을 확인 할 수 있었다. 본 논문에서는 환자와 유사하게 제작된 폐 팬텀에 실제 환자 호흡 패턴을 연동함으로 새로운 4D 치료선량 분포 검증 방법을 제시하였고 보다 사실적인 선량분포를 반영한 개별 환자 치료의 정확성 검증이 가능할 것으로 평가되었다.