• 제목/요약/키워드: Breathing Cycle

Search Result 63, Processing Time 0.029 seconds

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

An effect of time gating threshold (TGT) on a delivered dose in internal organ with movement due to respiration (호흡에 의해 내부 움직임을 갖는 장기에 전달되는 선량에서 Time Gating Threshold(TGT)의 효과)

  • Kim, Yon-Lae;Chung, Jin-Bum;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.132-135
    • /
    • 2004
  • In this study, we investigated the effect of threshold on a delivered dose in organ with internal motion by respiration. With mathematic model for 3D dose calculation reported by Lujan et al., we had calculated the position of organ as a function of time in previous study. This result presented that the variation of organ is within 2 mm from initial exhale position to the organ position during operating 1 s. Gating threshold, in this study, is determined to the moving region of target during 1s at a primary position of exhale. This period of gating threshold is 50% of the duty cycle in a half breathing cycle which is period from the top position of exhalation to the bottom position of inhalation. Radiation fields were then delivered under three conditions; 1) existent of moving target in the region of threshold(1sec, 1.5sec), 2) existent of moving target out of the region of threshold, 3) non-moving target. The non-moving target delivery represents a dose different induced due to internal organ motion.

  • PDF

Sleep Disorder and Alcohol (수면장애와 알코올)

  • Cho, Sung Bae;Lee, Sang Haak
    • Sleep Medicine and Psychophysiology
    • /
    • v.24 no.1
    • /
    • pp.5-11
    • /
    • 2017
  • The use of alcohol is associated with the development and worsening of sleep disorder. Alcohol is generally known to have a sedative effect, but it has an arousal or sedative effect depending on the timing and drinking dose and directly affects REM sleep physiology. Alcohol acts on the central nervous system (CNS) to interfere with the sleep-wake cycle and to affect sleep-related hormone secretion. In addition, the ingestion of alcohol pre-sleep is associated with deterioration and development of sleep related breathing disorders (SBD). The increase in resistance of the upper respiratory tract and the decrease in sensitivity of the CNS respiratory center and the respiratory muscles are major mechanisms of alcohol-induced SBD, and result in snoring or apnea in healthy men or aggravating apnea in patients with OSA. Sleep-related restless leg syndrome and circadian rhythm disorders are common in alcohol use disorder patients. This review provides an assessment of scientific studies that investigated on the impact of alcohol ingestion on nocturnal sleep physiology and sleep disorders.

Technical Review of Slurry and Gelled Propellant (슬러리와 젤 추진제의 기술개발 동향)

  • Jeong, Byung-Hun;Ko, Seung-Won;Hwang, Kab-Sung;Han, Jeong-Sik;Hong, Myung-Pyo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.168-171
    • /
    • 2007
  • A technical review of current slurry and gelled propellants is presented. In advanced countries, it is confirmed that these propellants have high specific impulse, density, excellent handling, safety characteristics and thrust controllability through research since 1950s. Substantial researches have been pursued to characterize the rheological properties, spray/combustion phenomena and propulsion system design for the gel propellant characteristics. Slurry and gelled propellants are developing actively to applicate both military and space propulsion fields such as tactical missile, air-breathing ramjet, pulse detonation engine, and combined cycle engine of future propulsion mode.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFICIENCY OF A LOCAL VENTILATION SYSTEM AND THE PROTECTING FACE MASKS IN DENTAL LABORATORIES

  • Kim, Uoong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.95-102
    • /
    • 1989
  • This study was performed to study the efficiency of a local ventilation system, installed in dental laboratories, and of two types of protecting face masks. The dust originating from the workpiece as well as from the wheels and stones was collected on air filters in the cutting cycle during coarse and fine grinding, and in the subsequent polishing procedures of each specific dental material. The efficiency of the ventilation system was measured on the basis of weight reduction of dust in the breathing air at a distance about 20-40 cm from workpiece. The results were as follows: 1. Use of the local ventilation system reduced the amounts of respirable dust to an average level of 21.4%, although the efficiency of the local ventilation system varied depending upon materials used. 2. Mounting a nozzle on the tube improved the efficiency of the ventilation system considerably. The efficiency of the local ventilation system also increased as the workpiece was closing to the tube inlet. 3. With or without the local ventilation system, the distance between the position of the workpiece and sampler greatly affected the dust level. 4. The face masks covering the sampler improved the efficiency of the ventilation system considerably.

  • PDF

Design of an algorithm to calculate the amount of energy consumed during cycling (자전거 운동 시 소비되는 에너지량 계산 알고리즘 설계)

  • Lim, Myoung-Seong;Jeong, Jin-Hyoung;Lee, Sang-Sik;Jang, Jee-Hun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.78-90
    • /
    • 2021
  • The purpose of this study was to develop the mathematic algorithm for energy expenditure calculation during cycling as a part of the development of a higher value-added cycle. Participants were 60 university students (male 30, female 30). Energy expenditure was measured with breathing gas at 10 sec intervals by gas analyzer connected with stationary cycle ergometer. Values presented by commercial speedometer and preceding researches were used for verification of actual measurement values in this study. In conclusion, the mathematic algorithms for energy expenditure calculation during cycling were as follows. For male, energy expenditure(Kcal)=5.048×cycling time(min)-2.258, energy expenditure(Kcal)=(0.05×cycling velocity(kph))×(4.750×cycling time(min)+0.091). For female, energy expenditure(Kcal)=4.466×cycling time(min)-1.605, energy expenditure(Kcal)(cycling velocity≤20kph)=(0.05×cycling velocity(kph))×(4.151× cycling time(min)-0.736), energy expenditure(Kcal)(cycling velocity>20kph)=(0.04×cycling velocity(kph)) ×(4.151×cycling time(min) -0.736). And it is suggested that the developed algorithm with cycling time and velocity should be applied for the development of a higher value-added cycle.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF

Study on the Validation of the Gated Cone-Beam Computed Tomography on Radiation Therapeutic Linear Accelerator (방사선치료용 선형가속기를 이용한 Gated Cone-Beam CT의 유용성 연구)

  • Seo, Jeong-Min;Kim, Chan-Hyeong;Park, Byoung-Suk;Park, Cheol-Soo;Jang, Hyon-Chol;Kim, Joung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6932-6939
    • /
    • 2015
  • The respiration is one of important factor in the radiation therapy. The existing commercial method of cone-beam computed tomography on LINAC does not consider respiratory motion of patient hence the images are both distorted and inaccurate. In this study, the cone-beam computed tomography images have been reconstructed from back projection radiography of specific phase on breathing cycle which concerned about respiratory movement in radiation therapy. This study investigated how different between cone-beam CT images with and without gating respiratory movement, and this paper provides that guide and implementation of gated cone-beam CT on radiation therapeutic equipment.

Technical Review and Analysis of Ramjet/Scramjet Technology I. Ramjet Engine (Liquid Ramjet, Ducted Rocket) (램제트/스크램제트의 기술동향과 소요기술 분석 I. 램제트 엔진(액체램제트, 덕티드로켓))

  • Sung Hong-Gye;Yoon Hyun-Gull
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.1
    • /
    • pp.72-86
    • /
    • 2006
  • A technical review of current ramjet propulsion is presented. In addition to summarize the current status of ramjet technology, new key techniques like Boosting technique easily adapting total impulse of booster, flame stabilization technique with minimized ramjet combuster length, variable nozzle-inner-surface technique realizing wide flight-envelop, and thermal protection technique for long operating time are identified. Actually various Ramjet propulsion technology has been matured and expanding to both military and combined cycle application. Yet many opportunities remain to be challenged by future generations of explorers to utilize s typical ramjet propulsion system for multi-purpose(multi-platform and multi-target) missiles, for example, American JSSCM and Russian Yakhont missiles, improving both reliability of techniques and downsizing development cost of new propulsion system.