• Title/Summary/Keyword: Breast images

Search Result 234, Processing Time 0.038 seconds

Comparison of the second and third intercostal spaces regarding the use of internal mammary vessels as recipient vessels in DIEP flap breast reconstruction: An anatomical and clinical study

  • Seong, Ik Hyun;Woo, Kyong-Je
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.333-339
    • /
    • 2020
  • Background The purpose of this study was to compare the anatomical features of the internal mammary vessels (IMVs) at the second and third intercostal spaces (ICSs) with regard to their use as recipient vessels in deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. Methods A total of 38 consecutive DIEP breast reconstructions in 36 patients were performed using IMVs as recipient vessels between March 2017 and August 2018. The intraoperative findings and postoperative complications were analyzed. Anatomical analyses were performed using intraoperative measurements and computed tomography (CT) angiographic images. Results CT angiographic analysis revealed the mean diameter of the deep inferior epigastric artery to be 2.42±0.27 mm, while that of the deep inferior epigastric vein was 2.91±0.30 mm. A larger mean vessel diameter was observed at the second than at the third ICS for both the internal mammary artery (2.26±0.32 mm vs. 1.99±0.33 mm, respectively; P=0.001) and the internal mammary vein (IMv) (2.52±0.46 mm vs. 2.05±0.42 mm, respectively; P<0.001). Similarly, the second ICS was wider than the third (18.08±3.72 mm vs. 12.32±2.96 mm, respectively; P<0.001) and the distance from the medial sternal border to the medial IMv was greater (9.49±2.28 mm vs. 7.18±2.13 mm, respectively; P<0.001). Bifurcations of the IMv were found in 18.4% of cases at the second ICS and in 63.2% of cases at the third ICS. Conclusions The IMVs at the second ICS had more favorable anatomic features for use as recipient vessels in DIEP flap breast reconstruction than those at the third ICS.

Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass (유방 종괴의 감별진단을 위한 탈륨 스캔의 유용성)

  • Bae, Sang-Kyun;Yum, Ha-Yong;Lee, Chung-Han;Choi, Kyung-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.214-219
    • /
    • 1994
  • The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breat cancers, 10 cases(90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease(85%). Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  • PDF

A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports (DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF

Volumetric change of the latissimus dorsi muscle after immediate breast reconstruction with an extended latissimus dorsi musculocutaneous flap

  • Nam, Su Bong;Oh, Heung Chan;Choi, Jae Yeon;Bae, Seong Hwan;Choo, Ki Seok;Kim, Hyun Yul;Lee, Sang Hyup;Lee, Jae Woo
    • Archives of Plastic Surgery
    • /
    • v.46 no.2
    • /
    • pp.135-139
    • /
    • 2019
  • Background In immediate breast reconstruction using an extended latissimus dorsi musculocutaneous (eLDMC) flap, the volume of the flap decreases, which causes a secondary deformity of the breast shape. Since little research has investigated this decrease in muscle volume, the authors conducted an objective study to characterize the decrease in muscle volume after breast reconstruction using an eLDMC flap. Methods Research was conducted from October 2011 to November 2016. The subjects included 23 patients who underwent mastectomy due to breast cancer, received immediate reconstruction using an eLDMC flap without any adjuvant chemotherapy or radiotherapy, and received a computed tomography (CT) scan from days 7 to 10 after surgery and 6 to 8 months postoperatively. In 10 patients, an additional CT scan was conducted 18 months postoperatively. Axial CT scans were utilized to measure the volumetric change of the latissimus dorsi muscle during the follow-up period. Results In the 23 patients, an average decrease of 54.5% was observed in the latissimus dorsi muscle volume between the images obtained immediately postoperatively and the scans obtained 6 to 8 months after surgery. Ten patients showed an average additional decrease of 11.9% from 6-8 months to 18 months after surgery. Conclusions We studied changes in the volume of the latissimus dorsi muscle after surgery using an eLDMC flap performed after a mastectomy without adjuvant chemotherapy or radiotherapy. In this study, we found that immediate breast reconstruction using a latissimus dorsi muscle flap led to a decrease in muscle volume of up to 50%.

Segmentation of Mammography Breast Images using Automatic Segmen Adversarial Network with Unet Neural Networks

  • Suriya Priyadharsini.M;J.G.R Sathiaseelan
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.12
    • /
    • pp.151-160
    • /
    • 2023
  • Breast cancer is the most dangerous and deadly form of cancer. Initial detection of breast cancer can significantly improve treatment effectiveness. The second most common cancer among Indian women in rural areas. Early detection of symptoms and signs is the most important technique to effectively treat breast cancer, as it enhances the odds of receiving an earlier, more specialist care. As a result, it has the possible to significantly improve survival odds by delaying or entirely eliminating cancer. Mammography is a high-resolution radiography technique that is an important factor in avoiding and diagnosing cancer at an early stage. Automatic segmentation of the breast part using Mammography pictures can help reduce the area available for cancer search while also saving time and effort compared to manual segmentation. Autoencoder-like convolutional and deconvolutional neural networks (CN-DCNN) were utilised in previous studies to automatically segment the breast area in Mammography pictures. We present Automatic SegmenAN, a unique end-to-end adversarial neural network for the job of medical image segmentation, in this paper. Because image segmentation necessitates extensive, pixel-level labelling, a standard GAN's discriminator's single scalar real/fake output may be inefficient in providing steady and appropriate gradient feedback to the networks. Instead of utilising a fully convolutional neural network as the segmentor, we suggested a new adversarial critic network with a multi-scale L1 loss function to force the critic and segmentor to learn both global and local attributes that collect long- and short-range spatial relations among pixels. We demonstrate that an Automatic SegmenAN perspective is more up to date and reliable for segmentation tasks than the state-of-the-art U-net segmentation technique.

Microcalcification Detection Based on Region Growing Method with Contrast and Edge Sharpness in Digital X-ray Mammographic Images (명암 대비와 에지 선예도를 이용하는 영역 성장법에 의한 디지털 X선 맘모그램 영상에서의 미세 석회화 검출)

  • Won, C.H.;Kang, S.W.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.56-65
    • /
    • 2004
  • In this paper, we proposed the detection algorithm of microcalcification based on region growing method with contrast and edge sharpness in digital X-ray mammographic images. We extracted the local maximum pixel and watershed regions by using watershed algorithm. Then, we used the mean slope between local maximum and neighborhood pixels to extract microcalcification candidate pixels among local maximum pixels. During increasing threshold value to grow microcalcification region, at the maximum threshold value of the contrast and edge sharpness, the microcalcification area is decided. The regions of which area of grown candidate microcalfication region is larger than that of watershed region are excluded from microcalcifications. We showed the diagnosis algorithm can be used to aid diagnostic-radiologist in the early detection breast cancer.

The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique (유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Hong, In-Sik;Kim, Hyun-Joo;Jang, Hyun-Cheol;Park, Cheol-Soo;Park, Tae-Nam
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of 3D reconstruction images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, subtraction images and 3D reconstruction images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The 3D reconstruction images showed higher SNR at the lesion area, ductal area, and fat area that of the subtraction image. In addition, the CNR were not significantly different in the lesion area itself between the subtraction images and 3D reconstruction images.

A Hybrid Optimized Deep Learning Techniques for Analyzing Mammograms

  • Bandaru, Satish Babu;Deivarajan, Natarajasivan;Gatram, Rama Mohan Babu
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.10
    • /
    • pp.73-82
    • /
    • 2022
  • Early detection continues to be the mainstay of breast cancer control as well as the improvement of its treatment. Even so, the absence of cancer symptoms at the onset has early detection quite challenging. Therefore, various researchers continue to focus on cancer as a topic of health to try and make improvements from the perspectives of diagnosis, prevention, and treatment. This research's chief goal is development of a system with deep learning for classification of the breast cancer as non-malignant and malignant using mammogram images. The following two distinct approaches: the first one with the utilization of patches of the Region of Interest (ROI), and the second one with the utilization of the overall images is used. The proposed system is composed of the following two distinct stages: the pre-processing stage and the Convolution Neural Network (CNN) building stage. Of late, the use of meta-heuristic optimization algorithms has accomplished a lot of progress in resolving these problems. Teaching-Learning Based Optimization algorithm (TIBO) meta-heuristic was originally employed for resolving problems of continuous optimization. This work has offered the proposals of novel methods for training the Residual Network (ResNet) as well as the CNN based on the TLBO and the Genetic Algorithm (GA). The classification of breast cancer can be enhanced with direct application of the hybrid TLBO- GA. For this hybrid algorithm, the TLBO, i.e., a core component, will combine the following three distinct operators of the GA: coding, crossover, and mutation. In the TLBO, there is a representation of the optimization solutions as students. On the other hand, the hybrid TLBO-GA will have further division of the students as follows: the top students, the ordinary students, and the poor students. The experiments demonstrated that the proposed hybrid TLBO-GA is more effective than TLBO and GA.

Usefulness about BSGI (Breast Specific Gamma Imaging) in Breast Cancer Patients (유방암 환자에서 Breast Specific Gamma Imaging (BSGI)의 유용성)

  • Cho, Yong-Gwi;Pyo, Seong-Jae;Kim, Bong-Su;Shin, Chea-Ho;Cho, Jin-Woo;Yeo, Ji-Yeon;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.92-101
    • /
    • 2009
  • Purpose: Scintimammography is one of the screening tests for the early diagnosis of breast cancer. It has been widely accepted as very useful in assessing masses that have not been detected in breast scanning. This method is highly sensitive and specific with respect to the diagnosis of primary and relapsing breast cancer. It has some difficulties, however, in detecting tumors sized 1 cm and below due to the radioactivity around the breast and the geometrical structure of the equipment. The recent introduction of high-resolution Breast-specific Gamma Imaging (BSGI) has made it possible to more accurately discriminate between malignant and benign tumors than with any other test method. Thus, the possibility of an unnecessary biopsy being performed has decreased. The purpose of this study was to examine the diagnostic capacity of mammography, breast sonography, and scintimammography, which are used for the early diagnosis of known breast cancer, and of BSGI, and to evaluate the skillfulness of radiologists. Materials and Methods: The 53 volunteers participants who had no clinical manifestation of breast cancer underwent the BSGI in February 2009. In the BSGI procedure, scanning images were obtained from the craniocaudal projection (CC) and the mediolateral Oblique projection (MLO), as well as from the additional $80{\times}80$-matrix-sized views at various angles in the Present Time method, 10 minutes after the 25 mCi $^{99m}Tc$-MIBI was injected. Results: The results of the BSGI showed that two participants had masses in their breast tissue. As the results of the diagnosis of four participants were not clear, they were retested and the results of the second test were negative. The results of the clinical screening test for breast cancer showed that the sensitivity of BSGI, scintimammography, mammography, and breast sonography was 86.5%, 77.8%, 85~90%, and 66.7%, respectively, and that their specificity was 92.4%, 84.2%, 20~42%, and 68%, respectively. Conclusion: The autodiagnosis and breast cancer screening test are needed for the early diagnosis of breast cancer. It was not easy, however, to accurately determine the presence of a mass in the breast using the existing breast cancer screening test. The patients with unclear test findings were made to undergo a histologic biopsy for a more accurate diagnosis. It is expected that the BSGI can provide useful information for the early diagnosis of breast cancer and of primary breast cancer, and will reduce the performance of unnecessary biopsies because of its higher sensitivity and specificity than existing breast cancer screening tests.

  • PDF

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.