• 제목/요약/키워드: Breast Ultrasonography

검색결과 123건 처리시간 0.029초

Automated Breast Ultrasound: Interobserver Agreement, Diagnostic Value, and Associated Clinical Factors of Coronal-Plane Image Features

  • Guoxue Tang;Xin An;Huiling Xiang;Lixian Liu;Anhua Li;Xi Lin
    • Korean Journal of Radiology
    • /
    • 제21권5호
    • /
    • pp.550-560
    • /
    • 2020
  • Objective: To evaluate the interobserver agreement, diagnostic value, and associated clinical factors of automated breast ultrasound (ABUS) coronal features in differentiating breast lesions. Materials and Methods: This study enrolled 457 pathologically confirmed lesions in 387 female (age, 46.4 ± 10.3 years), including 377 masses and 80 non-mass lesions (NMLs). The unique coronal features, including retraction phenomenon, hyper- or hypoechoic rim (continuous or discontinuous), skipping sign, and white wall sign, were defined and recorded. The interobserver agreement on image type and coronal features was evaluated. Furthermore, clinical factors, including the lesion size, distance to the nipple or skin, palpability, and the histological grade were analyzed. Results: Among the 457 lesions, 296 were malignant and 161 were benign. The overall interobserver agreement for image type and all coronal features was moderate to good. For masses, the retraction phenomenon was significantly associated with malignancies (p < 0.001) and more frequently presented in small and superficial invasive carcinomas with a low histological grade (p = 0.027, 0.002, and < 0.001, respectively). Furthermore, continuous hyper- or hypoechoic rims were predictive of benign masses (p < 0.001), whereas discontinuous rims were predictive of malignancies (p < 0.001). A hyperechoic rim was more commonly detected in masses more distant from the nipple (p = 0.027), and a hypoechoic rim was more frequently found in large superficial masses (p < 0.001 for both). For NMLs, the skipping sign was a predictor of malignancies (p = 0.040). Conclusion: The coronal plane of ABUS may provide useful diagnostic value for breast lesions.

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

유방자가검진 이행정도별 건강신념의 차이와 이행요인 (Differences in Health Belief by Compliance Level with Breast Self-Examination and Predictors of BSE among Women)

  • 박경연
    • 기본간호학회지
    • /
    • 제16권4호
    • /
    • pp.472-480
    • /
    • 2009
  • Purpose: The purpose of this study was to explore differences in health belief by compliance level with breast self-examination (BSE) and the predictors of BSE compliance among women. Method: Using a convenience sampling method, 163 women were selected for the sample. Data were measured for each participant during the period between December 2008 and February 2009, and analyzed by chi-square test, t-test, Kruskal-Wallis test with post hoc, and logistic regression analysis. Samples were categorized into three groups by the compliance level of BSE for the last 6 months: Never-performers (i.e, women who had never performed BSE), irregularly-performers (i.e, women who performed BSE at least once), and regularly-performers (i.e, women who performed monthly BSE). Result: Significant differences were reported among never-performers, irregularly-performers and regularly-performers correlated to age, level of education, mammography, ultrasonography, clinical examination, benefit, and confidence. There was no significant difference between irregularly-performers and regularly performers. The significant factor influencing compliance with BSE was 'confidence', which explained 33.7% of the variance in compliance with BSE. Conclusion: Women who had more confidence in their ability to perform BSE were more likely to practice BSE. It is necessary to develop the strategy to enforce woman's confidence in complying with BSE.

  • PDF

유방암 선별검사의 경계연령에 대한 고찰 (Screening Examination of Breast Cancer: Review of the Recommended Guidelines)

  • 신명호;황미수;박복환
    • Journal of Yeungnam Medical Science
    • /
    • 제16권2호
    • /
    • pp.342-346
    • /
    • 1999
  • 영남대학교 의과대학 부속병원에서 1992년 3월부터 1999년 6월까지 유방암으로 확진된 820례 중 35세 미만인 예는 102례(12.4%)이며 60세 이상인 예는 122례(14.9%)로 젊은 여성에 있어서도 유방암환자가 잦은 빈도로 발견되었다. 유방촬영술 또는 유방초음파검사를 시행한 35세 이하군 49명의 유방촬영술의 병변검색율은 83.8%, 유방암에 대한 민감도는 67.6%이었고, 초음파검사의 병변검색율은 100%, 유방암에 대한 민감도는 87.2%이었다. 60세이상의 대조군 48명 중 유방촬영술을 시행한 경우는 34명이며, 유방초음파검사는 81명에서 시행되었다. 유방촬영술의 병변검색률은 100%, 유방암에 대한 민감도는 91.2%이였고, 초음파검사의 병변겸색율은 100%, 유방암에 대한 민감도는 96.7%이었다(표 2). 조직학적으로는 35세 이하군에서 침윤성 유도관상피암 30명(61.2%), 유도관내 암종 8명(16.3%)이며 핵분열정도는 I이 3.8%, II가 26.9%, III가 39.2%이었고, 60세이상의 대조군에서는 침윤성 유도관상피암 32명(66.6%), 유도관내 암종 4명(8.33%)이고 핵분열정도는 I이 9.4%, II가 31.3%, III가 59.4%이었다(표1, 표3). 결론적으로 35세 이하군의 조직학적 분류상 악성도가 높은 종양이 많고 발생빈도가 60세 이상군과 유의한 차이가 없으므로 조기유방암의 선별을 위해서는 American Cancer Society에서 권장하는 baseline mammogram의 시행시기인 35-40세보다 더 이른 시기에 선별검사가 필요하다고 생각한다.

  • PDF

Strategy for salvaging infected breast implants: lessons from the recovery of seven consecutive patients

  • Yeo, Hyeonjung;Lee, Dongkyu;Kim, Jin Soo;Eo, Pil Seon;Kim, Dong Kyu;Lee, Joon Seok;Kwon, Ki Tae;Lee, Jeeyeon;Park, Ho Yong;Yang, Jung Dug
    • Archives of Plastic Surgery
    • /
    • 제48권2호
    • /
    • pp.165-174
    • /
    • 2021
  • Background In recent years, implant-based breast reconstruction has been performed because of its simplicity, short operation time, and rapid recovery of patients. Several studies have reported treatment methods for implant surgery-related infection, which is a serious complication. The aim of this study was to introduce our strategy for salvaging infected implants and to evaluate its effectiveness. Methods The authors performed a retrospective study of 145 cases from 132 patients who underwent implant-based breast reconstruction from January 2012 to December 2018. Empirical antibiotics were immediately administered to patients with suspected infections. The patients then underwent salvage treatment including appropriate antibiotics, ultrasonography-guided aspiration, debridement, antibiotic lavage, and implant exchange through a multidisciplinary approach. Patient demographics, operative data, duration until drain removal, adjuvant treatment, and complications were analyzed. Results The total infection rate was 5.5% (8/145). A longer indwelling catheter period and adjuvant treatment were significantly associated with infection. The salvage treatment showed a success rate of 87.5% (7/8). Seven patients who received early aggressive salvage treatment recovered from infection. One patient with methicillin-resistant Staphylococcus aureus, who received salvage treatment 11 days after symptom onset, did not respond to drainage and antibiotic treatment. That patient subsequently underwent explantation. Conclusions In implant-based breast reconstruction, prevention of infection is of the utmost importance. However, if an infection is suspected, proactive empirical antibiotic therapy and collaboration with the necessary departments are required. Through a multidisciplinary approach and proactive early management, swift and appropriate salvage should be performed.

The Impact of Abdominal Liposuction on Abdominally Based Autologous Breast Reconstruction: A Systematic Review

  • Bond, Evalina S.;Soteropulos, Carol E.;Poore, Samuel O.
    • Archives of Plastic Surgery
    • /
    • 제49권3호
    • /
    • pp.324-331
    • /
    • 2022
  • Prior abdominal liposuction can be viewed as a relative or absolute contraindication to abdominally based autologous breast reconstruction given concerns for damaged perforators and scarring complicating intraoperative dissection. This systematic review aims to explore the outcomes of abdominally based breast reconstruction in patients with a history of abdominal liposuction. A Preferred Reporting Items for Systematic Reviews and Meta-Analyses-guided literature search was conducted using PubMed, Scopus, and Web of Science from the earliest available date through June 2020. Deep inferior epigastric perforator, muscle-sparing transverse rectus abdominis musculocutaneous (TRAM), superficial inferior epigastric artery, and pedicled TRAM flaps were included for evaluation. Complications included total or partial flap loss, fat necrosis, seroma, delayed wound healing, and donor site complications. After inclusion criteria were applied, 336 non-duplicate articles were screened, yielding 11 for final review, representing 55 flaps in 43 patients. There was no instance of total flap loss, eight (14.5%) flaps developed partial loss or fat necrosis, three (5.4%) flaps had delayed wound healing, and two (4.6%) patients had donor site complications. Most authors (8/11) utilized some type of preoperative imaging. Doppler ultrasonography was the most used modality, and these patients had the lowest rate of partial flap loss or flap fat necrosis (8%), followed by those without any preoperative imaging (10%). In conclusion, this review supports that patients undergoing abdominally based autologous breast reconstruction with a history of abdominal liposuction are not at an increased risk of flap or donor site complications. Although preoperative imaging was common, it did not reliably decrease complications. Further prospective studies are needed to address the role of imaging in improving outcomes.

컴퓨터보조진단을 이용한 유방 초음파영상에서의 미세석회화 검출 효율 (Detection Efficiency of Microcalcification using Computer Aided Diagnosis in the Breast Ultrasonography Images)

  • 이진수;고성진;강세식;김정훈;박형후;최석윤;김창수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.227-235
    • /
    • 2012
  • 유방영상은 유방 전체의 재현 가능한 영상을 만들며, 만져지지 않는 조기 유방암의 가장 중요한 소견인 미세석회화와 종괴를 발견할 수 있어 유방 질환의 일차적인 선별검사로 이용되고 있다. 유방 병변의 미세석회화는 조기 유방암의 진단에 있어서 중요한 병변으로 보고되고 있지만 유방초음파 검사에서 검출이 어렵다. 본 연구에서는 유방초음파 영상에서 미세석회화 검출을 위해 6가지의 질감분석 파라미터를 이용하였으며, 정상 초음파영상과 미세석회화가 보이는 초음파 영상 간의 병변인식률을 알아보았다. 실험결과로는 유방촬영영상과 유방 초음파영상에서 병변을 구별하는 컴퓨터자동진단 인식률은 70~98%로 상당히 높은 결과를 나타내었다. ROC 분석에서도 평균대조도와 엔트로피 파라미터의 특이도는 다소 낮게 나타났으나, 나머지 4개 파라미터의 민감도와 특이도는 90% 이상을 나타내어 초음파영상에서 미세석회화 검출의 가능성을 보였다. 향후 6가지 질감분석 알고리즘들 외에 추가적인 파라미터 알고리즘의 연구가 계속 진행되어 컴퓨터자동진단의 실용화기반을 마련한다면 전문의 진단의 예비단계로서 더욱 중요한 의미를 가질 것이며, 유방암의 조기진단에 매우 유용할 것으로 사료된다.

Breast Cancer Recurrence According to Molecular Subtype

  • Shim, Hee Jin;Kim, Sung Hun;Kang, Bong Joo;Choi, Byung Gil;Kim, Hyeon Sook;Cha, Eun Suk;Song, Byung Joo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권14호
    • /
    • pp.5539-5544
    • /
    • 2014
  • Background: To evaluate the location of tumor relapse and imaging modality for detection according to the breast cancer subtype: luminal A, luminal B, HER2 positive luminal B, nonluminal HER2 positive, and triple negative. Materials and Methods: A total of 1244 patients with breast cancer with known estrogen receptor (ER), progesterone receptor (PR), Ki-67 and human epidermal growth factor receptor 2 (HER2), who underwent breast surgery from 2009 to 2012 were analyzed. Patients were classified into the following categories: luminal A (n=458), luminal B (n=241), HER2 positive luminal B (n=227), nonluminal HER2 positive (n=145) and triple negative (n=173). A total of 105 cases of relapse were detected in 102 patients: locoregional recurrence (n=46), recurrence in the contralateral breast (n=28) and distant metastasis (n=31). Comparison of proportions was used to determine the difference between subtypes. Results: Relapse rates by subtypes are as follows: luminal A 23 of 458 (5.02%), luminal B 19 of 241(7.88%), HER2 positive luminal B 15 of 227 (6.61%), nonluminal HER2 postive 19 of 145 (13.10%) and triple negative 29 of 173(16.76%). Luminal A tumors had the lowest rate of recurrence and had significantly lower recurrence rate in comparison with nonluminal HER2 postive (p=0.0017) and triple negative subtypes (p<0.0001). Compared with all other subtypes except nonluminal HER2 positive, triple negative tumors had the highest rate of tumor recurrence (p<0.01). Triple negatives were most likely to develop contralateral recurrence against all subtypes (p<0.05). Detection rate of locoregional and contralateral tumor recurrence were 28.3% on mammography (n=17/60). Conclusions: Luminal A tumors are associated with a low risk of recurrence while triple negative lesions have a high risk. In case of triple negative tumors, the contralateral breast has much more recurrence as compared with all other subtype. In terms of detection rates, breast USG was the best modality for detecting tumor recurrence, compared with other modalities (p<0.05). Subtyping of breast tumors using a molecular gene expression panel can identify patients who have increased risk of recurrence and allow prediction of locations of tumor recurrence for each subtype.