• Title/Summary/Keyword: Breast US

Search Result 133, Processing Time 0.021 seconds

Breast Ultrasound Microvascular Imaging and Radiogenomics

  • Ah Young Park;Bo Kyoung Seo;Mi-Ryung Han
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.677-687
    • /
    • 2021
  • Microvascular ultrasound (US) techniques are advanced Doppler techniques that provide high sensitivity and spatial resolution for detailed visualization of low-flow vessels. Microvascular US imaging can be applied to breast lesion evaluation with or without US contrast agents. Microvascular US imaging without a contrast agent uses a sophisticated wall filtering system to selectively obtain low-flow Doppler signals from overlapped artifacts. Microvascular US imaging with second-generation contrast agents amplifies flow signals and makes them last longer, which facilitates hemodynamic evaluation of breast lesions. In this review article, we will introduce various microvascular US techniques, explain their clinical applications in breast cancer diagnosis and radiologic-histopathologic correlation, and provide a summary of a recent radiogenomic study using microvascular US.

Effects of Ultrasonic Waves Scanning on the Quality of Fried Chicken Breast (튀김 닭고기 가슴살의 품질에 영향을 미치는 초음파 주사 효과)

  • Jung In-Chul;Moon Yoon-Hee;Park Kyung-Sook;Youn Dong-Hwa
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.16 no.2
    • /
    • pp.192-198
    • /
    • 2006
  • This study was carried out to investigate the effect of ultrasonic wave scanning on the quality of fried chicken breast. The ultrasonic wave scanning time was 0(US-0), 3(US-3), 7(US-7) and 10(US-10) minutes, no respective comparison here. The moisture of raw breast was higher than that of flied chicken, while the crude protein, fat and ash of fried chicken were higher than those of raw breast(p<0.05). The moisture content was influenced by the ultrasonic waves scanning, but the crude protein, fat and ash were not. The $L^*$(lightness) and $b^*$(yellowness) values of fried chicken were higher than those of raw breast but the $a^*$(redness) value of raw breast was higher than that of fried chicken. The $L^*$ value was lowest in US-0, while the $a^*$ value was not significantly different and the $b^*$ value was lowest in US-7 among the fried chicken samples(p<0.05). The fried chicken was not influenced by the ultrasonic wave scanning, indicating that the longer scanning time increased the water holding capacity. The pH ranged from 6.54 to 6.93, and the calorie of fried was higher than that of raw breast, but was not influenced by the ultrasonic wave scanning time. The VBN content ranged from 8.73 to 12.3 mg%. The TBARS value of raw breast was lower than that of flied chicken and was not influenced by the ultrasonic wave scanning time. Total amino acid was highest in raw breast and lowest in US-3(p<0.05). The taste, texture and juiciness were superior with increasing scanning time, but flavor and Palatability were not significantly different among the fried chicken samples(p<0.05).

  • PDF

Beyond BI-RADS: Nonmass Abnormalities on Breast Ultrasound

  • Hiroko Tsunoda;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.134-145
    • /
    • 2024
  • Abnormalities on breast ultrasound (US) images which do not meet the criteria for masses are referred to as nonmass lesions. These features and outcomes have been investigated in several studies conducted by Asian researchers. However, the term "nonmass" is not included in the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) 5th edition for US. According to the Japan Association of Breast and Thyroid Sonology guidelines, breast lesions are divided into mass and nonmass. US findings of nonmass abnormalities are classified into five subtypes: abnormalities of the ducts, hypoechoic areas in the mammary glands, architectural distortion, multiple small cysts, and echogenic foci without a hypoechoic area. These findings can be benign or malignant; however, focal or segmental distributions and presence of calcifications suggest malignancy. Intraductal, invasive ductal, and lobular carcinomas can present as nonmass abnormalities. For the nonmass concept to be included in the next BI-RADS and be widely accepted in clinical practice, standardized terminologies, an interpretation algorithm, and outcome-based evidence are required for both screening and diagnostic US.

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses

  • Eun Ji Lee;Yun-Woo Chang
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1045-1054
    • /
    • 2020
  • Objective: This study aimed to evaluate the diagnostic value of combining the quantitative parameters of shear wave elastography (SWE) and superb microvascular imaging (SMI) to breast ultrasound (US) to differentiate between benign and malignant breast masses. Materials and Methods: A total of 200 pathologically confirmed breast lesions in 192 patients were retrospectively reviewed using breast US with B-mode imaging, SWE, and SMI. Breast masses were assessed based on the breast imaging reporting and data system (BI-RADS) and quantitative parameters using the maximum elasticity (Emax) and ratio (Eratio) in SWE and the vascular index in SMI (SMIVI). The area under the receiver operating characteristic curve (AUC) value, sensitivity, specificity, accuracy, negative predictive value, and positive predictive value of B-mode alone versus the combination of B-mode US with SWE or SMI of both parameters in differentiating between benign and malignant breast masses was compared, respectively. Hypothetical performances of selective downgrading of BI-RADS category 4a (set 1) and both upgrading of category 3 and downgrading of category 4a (set 2) were calculated. Results: Emax with a cutoff value of 86.45 kPa had the highest AUC value compared to Eratio of 3.57 or SMIVI of 3.35%. In set 1, the combination of B-mode with Emax or SMIVI had a significantly higher AUC value (0.829 and 0.778, respectively) than B-mode alone (0.719) (p < 0.001 and p = 0.047, respectively). B-mode US with the addition of Emax, Eratio, and SMIVI had the best diagnostic performance of AUC value (0.849). The accuracy and specificity increased significantly from 68.0% to 84.0% (p < 0.001) and from 46.1% to 79.1% (p < 0.001), respectively, and the sensitivity decreased from 97.6% to 90.6% without statistical loss (p = 0.199). Conclusion: Combining all quantitative values of SWE and SMI with B-mode US improved the diagnostic performance in differentiating between benign and malignant breast lesions.

Young Women with Breast Cancer in the United States and South Korea: Comparison of Demographics, Pathology and Management

  • Son, Byung Ho;Dominici, Laura S;Aydogan, Fatih;Shulman, Lawrence N;Ahn, Sei Hyn;Cho, Ja Young;Coopey, Suzanne B;Kim, Sung Bae;Min, H Elise;Valero, Monica;Wang, Jiping;Caragacianu, Diana;Gong, Gyung-yub;Hevelone, Nathanael D;Baek, Seunghee;Golshan, Mehra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2531-2535
    • /
    • 2015
  • Background: Breast cancer diagnosed in young women may be more aggressive, with higher rates of local and distant recurrence compared to the disease in older women. Epidemiologic evidence suggests that Korean women have a lower incidence of breast cancer than women in the United States, but that they present at a younger age than their American counterparts. We sought to compare risk factors and management of young women with breast cancer in Boston, Massachusetts (US) with those in Seoul, South Korea (KR). Materials and Methods: A retrospective review was performed of consecutive patients less than 35 years old with a diagnosis of breast cancer at academic cancer centers in the US and KR from 2000-2005. Patient data were obtained by chart review. Demographic, tumor and treatment characteristics were compared utilizing Pearson's chisquare or Wilcoxon rank-sum tests where appropriate. All differences were assessed as significant at the 0.05 level. Results: 205 patients from the US and 309 from KR were analyzed. Patients in US were more likely to have hormone receptor positive breast cancer, while patients in KR had a higher rate of triple negative lesions. Patients in US had a higher mean body mass index and more often reported use of birth control pills, while those in the KR were less likely to have a sentinel node procedure performed or to receive post mastectomy radiation. Conclusions: Patients under 35 diagnosed with breast cancer in the US and KR differ with respect to demographics, tumor characteristics and management. Although rates of breast conservation and mastectomy were similar, US patients were more likely to receive post mastectomy radiation. The lower use of sentinel node biopsy is explained by the later adoption of the technique in KR. Further evaluation is necessary to evaluate recurrence rates and survival in the setting of differing disease subtypes in these patients.

Clinical and Ultrasonographic Changes of the Breast after Use of Soy Isoflavones

  • Alipour, Sadaf;Afshar, Somayeh;Moini, Ashraf;Dastjerdi, Marzieh Vahid;Saberi, Azin;Bayani, Leila;Eslami, Bita;Hosseini, Ladan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6093-6095
    • /
    • 2012
  • Background: Phytoestrogens may be an alternative therapy in control of menopausal symptoms but their definite effects on breast tissue must be determined. Our study aimed to define the clinical and ultrasonographic changes of the breast after use of soy isoflavones in menopausal women. Materials and Methods: Menopausal women with hot flashes were randomly grouped as cases and controls and cases received soy isoflavones for 12 weeks. Breast examination (BE) and ultrasonography (US) were done at 0, 6 and 12 weeks. Tenderness and nodularity on BE were graded 1-4 by breast surgeons. Results: There were 30 women in the case and 26 in the control group. The mean age was 51.3 years and the mean age of menopause was 49.2 years. There was no change in the BE and US at 6 weeks in controls. In the case group, 10% had grade 1 tenderness and 13.3% grade 2 tenderness and grade 1 nodularity in BE accompanied with diffuse small cysts in US. At 12 weeks, there was no change in BE and US in the 2 groups. Conclusions: There was no statistically significant difference in the BE of the 2 groups at 6 and 12 weeks (p value=0.36 and 0.41 for nodularity and tenderness respectively) and in the US results. Although the literature contains many facts concerning PEs and the breast, further prospective studies are needed to identify structural breast changes produced by PEs in order to identify the appropriate dosage and indications of use.

Survival Rates of Breast Cancer Patients Aged 40 to 49 Years according to Detection Modality in Korea: Screening Ultrasound versus Mammography

  • So Yeon Won;Hyung Seok Park;Eun-Kyung Kim;Seung Il Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Youngjean Park;Seho Park;Min Jung Kim;Young Up Cho;Byeong-Woo Park
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.159-167
    • /
    • 2021
  • Objective: The aim of this study was to compare the survival rates of Korean females aged 40 to 49 years with breast cancer detected by supplemental screening ultrasound (US) or screening mammography alone. Materials and Methods: This single-institution retrospective study included 240 patients with breast cancer (mean age, 45.1 ± 2.8 years) detected by US or mammography who had undergone breast surgery between 2003 and 2008. Medical records were reviewed for clinicopathologic characteristics and detection methods. Disease-free survival (DFS) and overall survival (OS) were compared between patients with breast cancer in the US and mammography groups using the log-rank test. Multivariable cox regression analysis was used to identify independent variables associated with DFS and OS. Results: Among the 240 cases of breast cancer, 43 were detected by supplemental screening US and 197 by screening mammography (mean follow-up: 7.4 years, 93.3% with dense breasts). There were 19 recurrences and 16 deaths, all occurring in the mammography group. While the US group did not differ from the mammography group in tumor stage, the patients in this group were more likely to undergo breast-conserving surgery and radiation therapy than the mammography group. The US group also showed better DFS (p = 0.016); however, OS did not differ between the two groups (p = 0.058). In the multivariable analysis, the US group showed a lower risk of recurrence (hazard ratio, 0.097; 95% confidence interval, 0.001-0.705) compared to the mammography group. Conclusion: Our study found that Korean females aged 40-49 years with US-detected breast cancer showed better DFS than those with mammography-detected breast cancer. However, there were no statistically significant differences in OS.

US-guided 14G Core Needle Biopsy: Comparison Between Underestimated and Correctly Diagnosed Breast Cancers

  • Kim, Hana;Youk, Ji Hyun;Kim, Jeong-Ah;Gweon, Hye Mi;Jung, Woo-Hee;Son, Eun Ju
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3179-3183
    • /
    • 2014
  • Background: The purpose of study was to evaluate radiologic or clinical features of breast cancer undergoing ultrasound (US)-guided 14G core needle biopsy (CNB) and analyze the differences between underestimated and accurately diagnosed groups. Materials and Methods: Of 1,898 cases of US-guided 14G CNB in our institute, 233 cases were proven to be cancer by surgical pathology. The pathologic results from CNB were invasive ductal carcinoma (IDC) (n=157), ductal carcinoma in situ (DCIS) (n=40), high-risk lesions in 22 cases, and benign in 14 cases. Among high-risk lesions, 7 cases of atypical ductal hyperplasia (ADH) were reported as cancer and 11 cases of DCIS were proven IDC in surgical pathology. Some 29 DCIS cases and 157 cases of IDC were correctly diagnosed with CNB. The clinical and imaging features between underestimated and accurately diagnosed breast cancers were compared. Results: Of 233 cancer cases, underestimation occurred in 18 lesions (7.7%). Among underestimated cancers, CNB proven ADH (n=2) and DCIS (n=11) were diagnosed as IDC and CNB proven ADH (n=5) were diagnosed at DCIS finally. Among the 186 accurately diagnosed group, the CNB results were IDC (n=157) and DCIS (n=29). Comparison of underestimated and accurately diagnosed groups for BI-RADS category, margin of mass on mammography and US and orientation of lesion on US revealed statistically significant differences. Conclusions: Underestimation of US-guided 14G CNB occurred in 7.7% of breast cancers. Between underestimated and correctly diagnosed groups, BI-RADS category, margin of the mass on mammography and margin and orientation of the lesions on US were different.

Unusual US Findings of Diffuse Large B-Cell Lymphoma of the Breast: A Case Report (유방의 B세포 림프종의 비전형적 초음파 영상 소견: 증례 보고)

  • Kyung Eun Lee;Ok Hee Woo;Chung Yeul Kim;Kyu Ran Cho;Bo Kyoung Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.415-420
    • /
    • 2024
  • Lymphoma is an uncommon type of breast malignancy, with low prevalence. The ultrasonographic findings of breast lymphoma have been described as nonspecific. Breast lymphoma most commonly appears as a solitary hypoechoic mass on US, and usually shows hypervascularity on color Doppler US. Herein, we report an unusual case of breast lymphoma that presented as multiple bilateral hyperechoic nodules on US.