• Title/Summary/Keyword: Breaker

검색결과 940건 처리시간 0.027초

고전압 차단기용 솔레노이드의 특성해석 (Characteristics Analysis of the Solenoid for High-Voltage Circuit Breaker)

  • 윤소남;류재섭;함영복;노종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.382-385
    • /
    • 2003
  • In this paper, the solenoid for high-voltage circuit breaker which is composed of bobbin, solenoid coil, stationary core and plunger was studied. The solenoid is made of a soft magnetic iron bar with a large number of coil windings. when an electric current passes through this, this stationary core becomes the strong magnet used for hydraulic and pneumatic valve of a solenoid operated valve. For the performance evaluation of the solenoid for high-voltage circuit breaker, electromagnetic characteristics and dynamic characteristics were analyzed. And, the parameters which is related to performance improvement were investigated.

  • PDF

IEC 60909에 의한 삼상 고장계산 (Three-phase Fault Calculation by IEC 60909)

  • 손석금
    • 전기학회논문지P
    • /
    • 제63권1호
    • /
    • pp.12-18
    • /
    • 2014
  • This paper analyzes how to calculate the three phase short circuit current calculation procedures used in the IEC 60909 short circuit. It presented the new procedure of the fault current for the interrupting capacity of the circuit breaker. This procedure is applied to the future power system and calculates the fault current. Power demands are increased because of the growth of the economy for this reason, the fault current of the power system is largely increased and the fault current procedure for the proper interrupting capacity calculation of the existing or the new circuit breaker is essential. How to calculate the three phase short circuit current for ac electrical system and select the high voltage and low voltage circuit breaker based on IEC 60909 standards.

향후 DC 전력 계통에서의 자려 공진 DC 차단기에 관한 연구 (Study of Self-excited Resonant DC Circuit Breaker in Future DC Grid)

  • 곽정래;윤민한;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.396-397
    • /
    • 2015
  • With the increasing utilization of high-voltage, direct current (HVDC) transmissions in modern power systems, the DC grid is becoming a hot topic in academic and practical systems. In the DC grid, one of the urgent problems is the fast clearance of the DC fault in the DC network. One preferred method is to isolate the faulty point from the DC network in a short time. The DC circuit breaker is to interrupt the overcurrent after DC faults occur. In this paper, a self-excited resonant DC circuit breaker is an easy and cheap equipment to interrupt the DC fault current. The Mayr's arc model is utilized to simulate the self-excited DC circuit breaker in a DC test system in PSCAD/EMTDC.

  • PDF

고전압 차단기용 솔레노이드 액추에이터의 거동 (Behavior of the Solenoid Actuator for High-Voltage Circuit Breaker)

  • 윤소남;함영복;안병규;김고도
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.1-6
    • /
    • 2004
  • In the last few years, a considerable number of studies have been made on On-Off solenoid for fluid control. But, only few attempts have so far been made at solenoid actuator for high-voltage circuit breaker. In case of the high-pressure and high-flow system like high-voltage circuit breaker, a big size of On/Off solenoid is necessary which size is proportional to control pressure and flow rate. So, it is non-effective in the view point of system optimization. In this paper, On/Off solenoid actuator with the farce amplifier connected to the solenoid rod was proposed to get a high mechanical force and a fast response time. The magnetic force and the mechanical stress distributions were analysed using finite element analysis. The performances of suggested solenoid actuator were evaluated through the experimental results and compared with the analysis results.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

2중 한류 구조를 갖는 배선용 차단기의 차단성능 평가 연구 (A Study on Estimation of Interrupting capability on Molded Case Circuit Breaker including Current Limiting Unit)

  • 김용기;송중천;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.144-146
    • /
    • 2002
  • The latest development flow of MCCB(Molded Case Circuit Breaker) is largely separated from which are high capability of interrupting compact of size and multi-ability in functions. As follow of development of industrial system. MCCB which are including communication function and having a ultimate interrupting capability is required in electrical system. to attain an effective limitation of the peak let-through current and the let-through energy, the arc has to move rapidly off the contacts and has to increase the arc voltage which mainly effect to interrupt. In this paper. we made high performance circuit breaker which including current limiting unit which is attached to the main which is simulated by CAE tool that are repulsion force and mechanical dynamics after that we tested and finally selected optimized for circuit breaker.

  • PDF

칩브레이커의 형상과 절삭조건이 칩 절단과 표면거칠기에 미치는 영향 (Effect of Chip Breaker Shape and Cutting Condition on the Chip Breaking and Surface Roughness)

  • 나기철;태순호;이병곤
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.17-28
    • /
    • 1994
  • Chip breaking is important in lathe work for maintaining good surface of the products and safety of operator. The purpose of this study is to investigate the performance of chip breaking and chip shape resulted from the carbide inserts with grooved type and obstruction type chip breaker. Experiments have been performed under the following cutting conditions, (1) constant cutting speed with variable depth of cut and feed rate, (2) constant depth of cut with variable cutting speed and feed rate. Also, the flying distance of chip and it's distribution have been investigated. As a results, good performance of chip breaking can be obtained for small radius of curvature and land width of grooved type chip breaker. And the thickness of chip increase with the increase of feed rate and decrease of cutting speed, and the chip breaking becomes easier with the increase of chip thickness due to the large deformation rate. Obstraction type chip breaker shows better performance of surface roughness than the grooved type. The flying distance of the chips over 90% are less than 1 meter, and the distance decreases as the feed rate decreases.

  • PDF

Simplified Synthetic Testing Facility with Modified TRV Circuit

  • Chong, Jin-Kyo;Lee, Kyung Seob;Lee, Chang-Hoon;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.881-885
    • /
    • 2018
  • In order to develop a gas circuit breaker (GCB), the breaking performance of the short line fault (SLF) should be prioritized over that of the breaker terminal fault (BTF). In brief, it is necessary to evaluate the thermal characteristics of the insulating gas that is filled in a GCB. In the process of developing a GCB, many companies use the simplified synthetic testing facility (SSTF).In order to evaluate the SLF breaking performance of a GCB with a long minimum arcing time, a modifications to the conventional SSTF was proposed. In this study, we developed the SSTF with a modified transient recovery voltage circuit. The performance of the newly developed SSTF was verified by an $L_{90}$ breaking performance test on a rating combination of 170 kV, 50 kA, and 60 Hz.

전기철도 변전소의 직류고속도차단기 동작 감소방안에 관한 연구 (A Study on the DC High Speed Circuit Breaker(HSCB) in Electric Railway Substation System)

  • 허태복;김학련;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2004
  • This paper proposes a reduction method for the mis-operation analysis of the DC High Speed Circuit Breaker(HSCB) in electric railway substation system. The analysis method is based on present condition of operation which is a method for accuracy level up. There is reason to operation of HSCB that it is mis-operation of fault detection relay(50F), operation of ground fault relay(64P), and trouble of electric car. A countermeasure is relay resetting through field test, induction of GTOCB(Gate Turn Off Thyristor Circuit Breaker), HSVCB(High Speed Vacuum Circuit Breaker), coordination with electric car. The results presented in the paper can be used as a reference for maintenance free in electric railway substation system.

  • PDF

일체형 순수유압식 브레이커의 민감도해석에 의한 성능 향상 (Performance Improvement of an Integrated-type Fully-Hydraulic Breaker by Sensitivity Analysis)

  • 최석;장효환
    • 유공압시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.17-24
    • /
    • 2009
  • The performance improvement of a small-size integrated-type fully hydraulic breaker is studied in this paper. Mathematical modeling of the breaker is established and verified by experiment. Through sensitivity analysis using AMESim, the key design parameters are selected and nearly optimized to maximize the impact energy as well as to improve the dynamic characteristics such as the piston upper chamber pressure, piston and valve displacements. As a result, the impact energy, blows per minute(bpm) and output power are increased by 52.9%, 1%, and 55.6%, respectively compared with the current design. The dynamic characteristics of the piston upper chamber pressure, piston and valve displacements are also improved by the design change.

  • PDF