The breakdown characteristics of $N_2$ gas with lightning impulse voltage in the non-uniform electrode (불평등전극계에서 뇌임펄스전압에 대한 $N_2$기체의 절연파괴 특성)

  • Lee, Bok-Hee;Lee, Feng;Joe, Jeong-Hyeon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presents the experimental results on breakdown characteristics in $N_2$ gas under non-uniform electric fields caused by both the positive and negative lightning impulse voltages. $N_2$ gas have an advantage of eco-friendly and cost reduction, and safety aspects. In order to analyze the impulse pre-breakdown processes in $N_2$ gas, we carried out measurements and observations of the impulse breakdown voltages, pre-breakdown current and luminous signals. They were measured by a voltage divider, a shunt and a photo-multiplier tube, respectively. Additionally, the characteristics of discharge channels were observed by high speed cameras. The breakdown voltages in the positive polarity was lower than those in the negative polarity.

  • PDF

Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode (선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성)

  • Kim, In-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

Breakdown Characteristics of $SF_6$ Gas under Particle Contaminated Conditions (금속입자 오손시 $SF_6$가스의 절연파괴특성)

  • Kim, Min-Kyu;Moon, In-Wook;Kim, Ik-Soo;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.465-468
    • /
    • 1995
  • The gas-insulated switchgear(GIS) has made high-reliability, high-safety, compact substations possible by using $SF_6$ gas. They are likely to be further developed toward higher voltages and targer capacities, along with greater compactness and lower cost. Although $SF_6$ gas has excellent insulation performance, breakdown voltages are reduced by the conducting particles. Thus, extensive studies have been made on the breakdown characteristics of $SF_6$ gas in particle contaminated conditions. Experiments were carried out for fired particle and free particle in a coaxial electrode system with DC and AC voltages. This paper represents the experimental results of the processes involved in electrical breakdown in compressed $SF_6$ gas, where breakdown is initiated by conducting particles.

  • PDF

Partial Discharge Phenomenon with $SF_6$ Gas Pressures in Insulation consisting of Insulation Paper and $SF_6$ Gas (SF_6 가스와 절연지의 절연계에서 가스압력에 따른 부분방전현상)

  • 선종호;김광화;박정후;조정수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.65-71
    • /
    • 2001
  • This paper describes partial discharge phenomenon with SF6gas pressures in insulation consisting of insulation paper and SF6 gas. We made the specimens with SF6 gas gaps which exist between aramid papers and electrodes and calculated the electric field intensity in the these gaps. We measured the partial discharge inception voltages and the AC breakdown voltages with the test method of IEC 60060-2 and did the partial discharge degradation experiments with a constant voltage. According to gas pressures, the breakdown voltages in SF6gas gaps were calculated by Paschen's law. And these results showed the ability applying partial discharge inception voltages evaluation to Paschen's law and the relationship between the PD quantities occurring insulation breakdown and PD occurring area.

  • PDF

Electrical Breakdown Strength of Insulation under Combined DC-AC Voltages

  • Grzybowski, S.
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.32-39
    • /
    • 1998
  • Electrical breakdown strength of paper-oil and polypropylene/film-oil insulation samples was measured under dc, ac and pulsating voltages. The latter was obtained by superimposing ac upon dc volate and provides an attractive method for a simultaneous testing and assessment of the state of insulation of the various parts of HV apparatus in service. The measurements were carried out over a wide range of the pulsation ratio defined as p=Eac/Edc. The results obtained under pulsating voltages follow colsely an experssion which relates the breakdown strength to the sum of arc tangent and arc cotangent function of the parameter p. The study was carried out using dry paper as well as paper containing various degrees of moisture. The presence of moisture showed a pronounced effect upon the breakdown strength which varied with the pulsation parameter p.

  • PDF

The Bouncing Characteristics of Particles in GIS Chamber (GIS가스 챔버 내에서 파티클 부상특성)

  • Lee, Kang-Soo;Kwak, Hee-Ro;Cho, Yong-Woo;Kim, Kyong-Hwa;Cho, Kook-Hee;Kweon, Dong-Jin;Jun, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1850-1852
    • /
    • 1997
  • In this paper, the behavior and effect of conducting particles in a $SF_6$ insulated electrode system, are presented. It is shown that the bouncing voltage of the particle is independent of particle length, and that the breakdown voltages are affected by the particle length. The longer the particle, the lower the breakdown voltages. The bouncing-off, the lift off and breakdown voltages increase as the particle diameter increase. The breakdown voltage of free particle is lower than fixed particle on the enclosure.

  • PDF

A Basic Study on a New Type Particulate Emission Control Means of a Power Station Using a Micro-Gap and a Pulse Discharge (Micro-Airgap Discharge Phenomena) (초미소간격(超微小間隔)과 극단(極端)펄스방전(放電)을 이용(利用)한 미연소탄소립자(未燃燒炭素粒子) 소각제거기술(燒却除去技術) 개발기초연구(開發基礎硏究)(I) (초미소간격(超微小間隔)의 방전현상(放電現象)))

  • Moon, Jae-Duk;Shin, Soo-Youn
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.605-608
    • /
    • 1993
  • Breakdown characteristics of a small rod-to-rod microairgap has been studied for obtain an optimum breakdown voltage and an airgap spacing to be used as an emission control means by the electrical arc-burning unburnt carbon particulates exhausted from a power station burner. It is found that the breakdown voltage at the rod-to-rod airgap spacing in the rang of $1{\sim}100{\mu}m$ decreased with decrease in the rod-to-rod airgap spacing. And there were no minimum breakdown voltage on a $V_b$-Pd characteristics which is known as the minimum voltage in Paschen's law in air atmosphere. Breakdown voltages of the airgap at the constant airgap spacing were $V_{b-dc}>V_{b-ac}>V_{b-pulse}$, and it was lowest for the pulse voltage applied. As a result, it is found that a pulse power was one of effective power compared with dc or ac to be used as such an unburnt carbon particulate emission control means and the airgap spacing became to several tens ${\mu}m$, then the breakdown voltages were down to several handreds voltages.

  • PDF

Reverse voltage characteristics of 4H SiC Schottky Diode by Edge termination Method (4H 탄화규소 쇼트키 다이오드에서 접합종단기법에 따른 항복전압특성)

  • Cheong, Hui-Jong;Bahng, Wook;Kang, In-Ho;Kim, Sang-Cheol;Han, Hyeon-Sook;Kim, Nam-Kyun;Lee, Yong-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.191-192
    • /
    • 2005
  • The reverse breakdown voltages of 4H-SiC SBD(schottky barrier diode)s with FP(Field Plate) and/or FLR(Field Limiting Ring) as a edge termination, were investigated. The breakdown voltages of SBDs with FP ware investigated varying the overlap width from $1{\mu}m$ to $30{\mu}m$. The maximum average breakdown voltages was 475V. There is no significant changes for the devices with overlap width of between $5{\mu}m\sim30{\mu}m$. It was confirmed that the dielectric breakdown of the thin thermal oxide is main cause of device failure. However, the breakdown voltage of SBD with FLR was 1400V even though the FLR edge termination structure was not optimized.

  • PDF

A Basic Study on the Attachment Process of Lightning Leader to Ground (낙뢰 리더의 대지부착과정에 대한 기초적 연구)

  • Yoo, Yang-Woo;Kim, Seung-Min;Kim, You-Ha;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.82-88
    • /
    • 2014
  • This paper presents the results of model tests for the attachment process of lightning leader to ground which is one of poorly understood processes of cloud-to-ground lightning discharges. In order to simulate the attachment process of lightning leader to ground, we investigated the discharge characteristics of air gap between the tip of needle-shaped electrode and the soil surface as a parameter of moisture content in soils when the positive and negative $1.2/50{\mu}s$ lightning impulse voltages are applied. The breakdown voltage and the discharge light were observed. As a result, the attachment processes of lightning leader to ground are strongly dependent on the grain size and the moisture content of soils. The time to breakdown was shortened with increasing the magnitude of incident impulse voltages. The delay time from application of the highest voltage to breakdown in sand is shortened with increasing the moisture content. The delay time from application of the voltage to breakdown in gravel varied from about $0.5{\mu}s$ to several ${\mu}s$. As the moisture content in soil increases, the breakdown voltages are decreased and the breakdown voltage versus time to breakdown curves are shifted toward the lower side. The results obtained in this work are similar to those for non-uniform air gap stressed by lightning impulse voltages.

Characterization of gate oxide breakdown in junctionless amorphous InGaZnO thin film transistors (무접합 비정질 InGaZnO 박막 트랜지스터의 게이트 산화층 항복 특성)

  • Chang, Yoo Jin;Seo, Jin Hyung;Park, Jong Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.117-124
    • /
    • 2018
  • Junctionless amorphous InGaZnO thin film transistors with different film thickness have been fabricated. Their device performance parameters were extracted and gate oxide breakdown voltages were analyzed with different film thickness. The device performances were enhanced with increase of film thickness but the gate oxide breakdown voltages were decreased. The device performances were enhanced with increase of temperatures but the gate oxide breakdown voltages were decreased due to the increased drain current. The drain current under illumination was increased due to photo-excited electron-hole pair generation but the gate oxide breakdown voltages were decreased. The reason for decreased breakdown voltage with increase of film thickness, operation temperature and light intensity was due to the increased number of channel electrons and more injection into the gate oxide layer. One should decide the gate oxide thickness with considering the film thickness and operating temperature when one decides to replace the junctionless amorphous InGaZnO thin film transistors as BEOL transistors.