• 제목/요약/키워드: Breakdown stress

검색결과 224건 처리시간 0.022초

p-n 접합에 있어서의 비등방성 응력효과 (Anisotropic stress Effects in p-n junction)

  • 손병기;이건일
    • 대한전자공학회논문지
    • /
    • 제11권3호
    • /
    • pp.22-26
    • /
    • 1974
  • The effects of anisotropic mechanical stress applied normal to the surface of p-n junctions have been investigated. As the stress increased, the breakdown voltage was decreased and the breakdown mode became softer. Within a certain limitation in the applied stress, the above phenomena werw reversibbe, though relaxation and hysteresis phenomena were observed. The time constant of relaxation depended upon the shape of the stressing tip, but for the given tip and device a unique time constant was obtained. The stress.dependence of breakdown voltage showed a good linearity up to about 3.0${\times}10^4$ kgw/$\textrm{cm}^2$, when the flat tip of radius 15$\mu$ was used, and the temperatere-dependence of breakdown voltage under the stress also showed a good linearity in the temperature range of 100 to $300^{\circ}K$.

  • PDF

Alterations of breakdown and collapse pressures due to material nonlinearities

  • Nawrocki, Pawel A.
    • Geomechanics and Engineering
    • /
    • 제1권2호
    • /
    • pp.155-168
    • /
    • 2009
  • Breakdown pressures obtained from the classic, linear elastic breakdown model are compared with the corresponding pressures obtained using a nonlinear material model. Compression test results obtained on sandstone and siltstone are used for that purpose together with previously formulated nonlinear model which introduces elasticity functions to address nonlinear stress-strain behaviour of rocks exhibiting stress-dependent mechanical properties. Linear and nonlinear collapse pressures are also compared and it is shown that material nonlinearities have significant effect on both breakdown and collapse pressures and on tangential stresses which control breakdown pressure around a borehole. This means that the estimates of ${\sigma}_H$ made using linear models give stress values which are different than the real values in the earth. Thus the importance of a more accurate analysis, such as provided by the nonlinear models, is emphasised. It is shown, however, that the linear elastic model does not necessarily over-predict borehole stresses and the opposite case can be true, depending on rock type and test interpretation.

고정자권선의 절연열화 특성분석 (Analysis of the Insulation aging for the stator winding)

  • 오봉근;최교남;한창동;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF

액체질소 중에서 기계적 응력에 따른 mini-model 케이블의 전기적 특성 (The Electrical Properties of Mini-model Cable under mechanical stress in Liquid Nitrogen)

  • 김영석;곽동순;한철수;김해종;성기철;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.22-27
    • /
    • 2004
  • It is important to mechanical properties of dielectric paper and cable to optimum electrical insulation design of HTS cable, because the cable has experience of mechanical stress, such as tensile stress, bending stress. Also, it is operated at cryogenic temperature. From the results, it was observed that the tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen is decreased. Because PPLP was deteriorated by microcrack and tensile strain. According as bending radius multiple is decrease, the ac and impulse breakdown stress of mini-model cable is sharply decreased.

기계적 응력상태에서 절연지 및 케이블의 전기절연 특성 (The Characteristics of Electrical Breakdown of Dielectric Paper and Cable under mechanical stress)

  • 김영석;곽동순;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 제5회 영호남 학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2003
  • The electrical and mechanical properties of dielectric paper and cable at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. From the results, Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased because PPLP was degradated. According as bending radius multiple is decrese, breakdown voltage decreased sharply. And bending radius multiple is thought that more than about 25 is suitable.

  • PDF

Breakdown Characteristics and Lifetime Estimation of Rubber Insulating Gloves Using Statistical Models

  • Kim, Doo Hyun;Kang, Dong Kyu
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.36-42
    • /
    • 2002
  • This paper is aimed at predicting the life of rubber insulating gloves under normal operating stresses from relatively rapid test performed at higher stresses. Specimens of rubber insulating gloves are subject to multiple stress conditions, i.e. combined electrical and thermal stresses. Two modes of electrical stress, step voltage stress and constant voltage stress are used in specimen aging. There are two types of test for electrical stress in this experiment: the one is Breakdown Voltage (BDV) test under step voltage stress and thermal stress and the other is lifetime test under constant voltage stress and temperature stress. The ac breakdown voltage defined as the break-down point of insulation that leakage current excesses a limit value, l0mA in this experiment, is determined. Because the very high variability of aging data requires the application of statistical model, Weibull distribution is used to represent the failure times as the straight line on Weibull probability paper. Weibull parameters are deter-mined by three statistical methods i.e. maximum likelihood method, graphical method and least squares method, which employ SAS package, Weibull probability paper and FORTRAN, respectively. Two chosen models for predicting the life under simultaneous electrical and thermal stresses are inverse power model and exponential model. And the constants of life equation for multistress aging are calculated using numerical method, such as Gauss Jordan method etc.. The completion of life equation enables to estimate the life at normal stress based on the data collected from accelerated aging test. Also the comparison of the calculated lifetimes between the inverse power model and the exponential model is carried out. And the lifetimes calculated by three statistical methods with lower voltage than test voltage are compared. The results obtained from the suggested experimental method are presented and discussed.

Aspects of Hard Breakdown Characteristics in a 2.2-nm-thick $SiO_2$ Film

  • Komiya, Kenji;Omura, Yasuhisa
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제2권3호
    • /
    • pp.164-169
    • /
    • 2002
  • This paper mainly discusses the hard breakdown of 2.2-nm-thick $SiO_2$ films. It is shown that the hard breakdown event of a 2.2-nm-thick $SiO_2$ film greatly depends on the applied electric field. It is strongly suggested that the local weak spots created by applying a low initial stress to a 2.2-nm-thick $SiO_2$film resist the onset of hard breakdown. In other words, it is anticipated that the stored electrostatic energy is fast dissipated by trap-assisted tunneling in 2.2-nm-thick $SiO_2$ film. Consequently, it is strongly suggested that 2.2-nm-thick $SiO_2$ films are intrinsically quite robust.

얇은 절연막의 TDDB 분석과 전기적 특성 (TDDB Analysis and Electrical Characteristics of Thin Insulator Films)

  • 박찬원;김복헌
    • 산업기술연구
    • /
    • 제8권
    • /
    • pp.23-30
    • /
    • 1988
  • In this paper, the characteristics of electrical breakdown and TDDR (Time Dependant Dielectric Breakdown) were studied to evaluate stability and reliability of thin insulator films such as oxide and nitride. As the oxide film thickness decreased, the electrical breakdown field was increased proportioning to its reverse square root, ${d^{-\frac{1}{2}}}$. As for the temperature dependance of breakdown field, its field was inclined to decrease as temperature increased. It also showed that oxide charge (Qss) was changed by stress field and stress time. Consequently, TDDB characteristics and breakdown mechanism proved the improvement of reliability and stability and provided the accurate analysis to predict a device life time.

  • PDF

고온 초전도 케이블 절연을 위한 절연지의 인장응력 및 절연파괴 특성 (The Characteristics of Electrical Breakdown and Tensile Stress of Dielectric Paper for Insulation of HTS Cable)

  • 김영석;곽동순;김해종;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.61-64
    • /
    • 2003
  • The degradation of the dielectric properties of insulating papers that were used under loaded conditions at cryogenic temperature was paid attention. Electrical and tensile stress properties of dielectric paper at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased.

  • PDF

Survival of the Insulator under the electrical stress condition at cryogenic temperature

  • Baek, Seung-Myeong;Kim, Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.10-14
    • /
    • 2013
  • We have clearly investigated with respect to the survival of the insulator at cryogenic temperature under the electrical stress. The breakdown and voltage-time characteristics of turn-to-turn models for point contact geometry and surface contact geometry using copper multi wrapped with polyimide film for an HTS transformer were investigated under AC and impulse voltage at 77 K. Polyimide film (Kapton) 0.025 mm thick is used for multi wrapping of the electrode. As expected, the breakdown voltages for the surface contact geometry are lower than that of the point contact geometry, because the contact area of the surface contact geometry is lager than that of the point contact geometry. The time to breakdown t50 decreases as the applied voltage is increased, and the lifetime indices increase slightly as the number of layers is increased. The electric field amplitude at the position where breakdown occurs is about 80 % of the maximum electric field value. The relationship between survival probability and the electrical stress at cryogenic temperature was evident.