• Title/Summary/Keyword: Breakdown location

Search Result 56, Processing Time 0.025 seconds

A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines (UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구)

  • Park, Hung-Sok;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

Breakdown Points of Direction Tests

  • Park, Kyung-Mee
    • Journal of the Korean Statistical Society
    • /
    • v.26 no.2
    • /
    • pp.211-222
    • /
    • 1997
  • We briefly review three Raleigh type location tests based on direction vectors, which have been shown to be efficient when the distribution is unknown, skewed, or heavy-tailed. Then we calculate their test breakdown points and discuss the robustness of Randles multivariate sign test for one-sample.

  • PDF

A Study on High Breakdown Discriminant Analysis : A Monte Carlo Simulation

  • Moon Sup;Young Joo;Youngjo
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.1
    • /
    • pp.225-232
    • /
    • 2000
  • The linear and quadratic discrimination functions based on normal theory are widely used to classify an observation to one of predefined groups. But the discriminant functions are sensitive to outliers. A high breakdown procedure to estimate location and scatter of multivariate data is the minimum volume ellipsoid or MVE estimator To obtain high breakdown classifiers outliers in multivariate data are detected by using the robust Mahalanobis distance based on MVE estimators and the weighted estimators are inserted in the functions for classification. A samll-sample MOnte Carlo study shows that the high breakdown robust procedures perform better than the classical classifiers.

  • PDF

Improvement of Breakdown Characteristics Using Ribbed Spacer of GIS (GIS 립 스페이서에 의한 파괴전압 특성 개선)

  • 류성식;최영찬;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.28-33
    • /
    • 2001
  • This paper describes the effect of various conditions of the ribs on the breakdown characteristics when metal particle is attached to the spacer in GIS. More improved spacer shape in breakdown characteristics than conventional one is proposed by comparing the results acquired by varying location, length and thickness of the ribbed spacer. As a result, it was found that the electrical breakdown characteristics of the spacer with two ribs were generally better than that with only one rib or no ribs, and it was dependent on the rib length and rib thickness. Especially, it was also confirmed that the electrical breakdown characteristics were more improved by rounding the rib edge.

  • PDF

Breakdown Voltage and On-resistance Analysis of Partial-isolation LDMOS (Partial-isolation LDMOS의 항복전압과 온저항 분석)

  • Sin-Wook Kim;Myoung-jin Lee
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.567-572
    • /
    • 2023
  • In this paper, the breakdown voltage of Pi-LDMOS (Partial isolation lateral double diffused metal oxide semiconductor) was analyzed by simulation. Breakdown voltage variation is investigated under various settings of Parial buied oxide(P-BOX) parameters(length, thickness, location) and their mechanism is specified. In addition, the change in on-resistance in the breakdown voltage and trade-off relationship was analyzed according to the change in the P-BOX parameter, and the Figure-of-merit(FOM) was calculated and compared. In proposed structure, Lbox=5 ㎛, tbox=2 ㎛, and Lbc=2 ㎛ showed the highest breakdown voltage of 138V, and Lbox=5 ㎛, tbox=1.6 ㎛, and Lbc=2 ㎛ showed the highest FOM. Compared to conventional LDMOS, the breakdown voltage is 123% and FOM is 3.89 times improved. Therefore, Pi-LDMOS has a high breakdown voltage and FOM, which can contribute to the improvement of the stable operating range of the Power IC.

The Insulation Characteristics by Conducting Particle in GIS (GIS내 금속이물 존재시 절연특성)

  • Cho, Kook-Hee;Kim, Jae-Chul;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.105-108
    • /
    • 2004
  • This paper describes the influence of conducting particle in the coaxial cylindrical electrodes under alternating voltage condition investigated using breakdown electric field and electro magnetics simulation method. Simulated particle-location in GIS chamber were the particle on electrode, the particle on enclosure and free moving particle. As results, it was founded that in case of breakdown electric field of the GIS chamber, breakdown electric field of particle on electrode was the lowest, that of free moving particle was middle and that of particle on enclosure was the highest. And in case of the electric field analysis with particle locations, electric field of particle on electrode was the highest that of lifted particle was middle and that of particle on enclosure was the lowest. This results can offer a practical reference ra the insulation design of domestic GIS.

  • PDF

A Robust Test for Location Parameters in Multivariate Data (다변량 자료에서 위치모수에 대한 로버스트 검정)

  • So, Sun-Ha;Lee, Dong-Hee;Jung, Byoung-Cheo
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.6
    • /
    • pp.1355-1364
    • /
    • 2009
  • This work propose a robust test for location parameters in multivariate data based on MVE and MCD with the affine equivariance and the high-breakdown properties. We consider the hypothesis testing satisfying high efficiency and high test power simultaneously to bring in the one-step reweighting procedure upon high-breakdown estimators, which generally suffer from the low efficiency and, as a result, usually used only in the exploratory analysis. Monte Carlo study shows that the suggested method retains nominal significance levels and higher testing power without regard to various population distributions than a Hotelling's $T^2$ test. In an example, a data set containing known outliers does not make an influence toward our proposal, while it renders a Hotelling's $T^2$ useless.

Issues on Spatial Reflection of De-differentiation in Jeju Island (탈분화의 공간적 반영 - 제주관광을 사례로 -)

  • 오정준
    • Journal of the Korean Geographical Society
    • /
    • v.39 no.3
    • /
    • pp.391-408
    • /
    • 2004
  • Modernism is understood as a process of differentiation. Postmodernism or postmodernity, by contrast, involves de-differentiation. There is a breakdown in the distinctiveness of each of spheres of social activities. It is important to explain an examination of the relationships between the de-differentiation and a wide variety of contemporary tourism, expecially postmodern tourism. Also, de-differentiation between the tourism and the social spheres lead to the spatial reflection. Aim of this paper is to examine the processes of de-differentiation between the tourism and the social spheres, which comes out spatially in Jeju island. Especially, location of destinations is concentrated on the coastline in the period of modem tourism. On the contrary, the postmodern tourism shows that the location of destinations are wide spread diffusion its vertically and horizontally. It means that there are to appear a breakdown of distinctiveness between the conventional tourism destinations and the regional person's space.

Application of Acoustic Emission Technique for Crack Source Location Search in Plain Concrete (무근 콘크리트에서 균열 발생원 탐사를 위한 AE 기법의 적용)

  • 한상훈;이웅종;조홍동;김동규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.793-798
    • /
    • 1999
  • This study was conducted to evaluate structural integrity and crack source location of plain concrete beams using acoustic emission. Three point bending tests were carried out plain concrete specimen under cyclic loadings. The variable is W/C of concrete. From the tests it was shown that a breakdown of the kaiser effect and high AE activities during unloading could be effective indices to estimate the level of deterioration in plain concrete structures. The time and location and propagation of crack could be easily determined by monitoring AE, which concludes that AE technique can be a very useful tool to evaluate structural integrity of concrete plain beams.

  • PDF

The Insulation Characteristics and The Electric Field Anlaysis by Conducting Particle in $SF_6$ Gas ($SF_6$가스 내 금속이물 존재시 절연특성 및 전계해석)

  • 조국희;이동준;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.14-19
    • /
    • 2001
  • This paper describes the influence of conducting particle in the coaxial cylindrical electrodes under alternating voltage condition investigated using breakdown electric field and electro magnetics simulation method. Simulated particle-location in GIS chamber were the particle on electrode, the particle on enclosure and free moving particle. As results, it was founded that in case of breakdown electric field of the GIS chamber, breakdown electric field of particle on electrode was the lowest, that of free moving particle was middle and that of particle on enclosure was the highest. And in case of the electric field analysis with particle locations, electric field of particle on electrode was the highest, that of lifted particle was middle and that of particle on enclosure was the lowest. This results can offer a practical reference on the insulation design of domestic GIS.

  • PDF